UNE-EN 54-3:2016

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Fire detection and fire alarm systems - Part 3: Fire alarm devices - Sounders
Available format(s)

Hardcopy , PDF

Superseded date

11-01-2020

Language(s)

Spanish, Castilian, English

Published date

06-04-2016

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
  4.1 Compliance
  4.2 Sound level
  4.3 Frequency and sound pattern
  4.4 Durability
  4.5 Construction
  4.6 Marking and data
5 Tests
  5.1 General
  5.2 Reproducibility
  5.3 Operational performance
  5.4 Durability
  5.5 Dry heat (operational)
  5.6 Dry heat (endurance)
  5.7 Cold (operational)
  5.8 Damp heat, cyclic (operational)
  5.9 Damp heat, steady state (endurance)
  5.10 Damp heat, cyclic (endurance)
  5.11 Sulfur dioxide (SO[2]) corrosion (endurance)
  5.12 Shock (operational)
  5.13 Impact (operational)
  5.14 Vibration, sinusoidal (operational)
  5.15 Vibration, sinusoidal (endurance)
  5.16 Electromagnetic compatibility (EMC), immunity
       (operational)
  5.17 Enclosure protection
Annexes
Annex A (normative) - Sound level test for fire alarm
                         sounders
A.1 General
A.2 Mounting arrangements
A.3 Instrumentation
A.4 Background noise level
A.5 Measurement of sound level
Annex B (normative) - Comparative sound level test during
                         environmental conditioning
B.1 General
B.2 Test chamber
B.3 Mounting arrangements
B.4 Instrumentation
B.5 Background noise level
B.6 Test procedure
Annex ZA (informative) - Clauses of this European Standard
                         addressing essential requirements
                         or other provisions of EU Directives
ZA.1 Scope and relevant clauses
ZA.2 Procedures for the attestation of conformity of fire
     alarm sounders covered by this standard
ZA.3 CE marking and labelling and accompanying documentation
ZA.4 EC certificate and declaration of conformity
Bibliography

Specifies the requirements, test methods and performance criteria for fire alarm sounders in a fixed installation intended to signal an audible warning of fire between fire detection and fire alarm system and the occupants of a building.

Committee
CTN 23
DocumentType
Standard
Pages
76
PublisherName
Asociacion Espanola de Normalizacion
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
NBN EN 54-3 : 2014 Identical
NEN EN 54-3 : 2014+A1:2019 Identical
UNI EN 54-3 : 2014 Identical
I.S. EN 54-3:2014 Identical
EN 54-3:2014 Identical
ONORM EN 54-3 : 2014 Identical
NF EN 54-3 : 2014 Identical
DIN EN 54-3:2014-09 Identical
SN EN 54-3:2014 Identical
BS EN 54-3:2014 Identical
NS EN 54-3 : 2014 Identical
DIN EN 54-3:2001-10 Identical

UNE 23007-14:2014 Fire detection and fire alarm systems. Part 14: Planning, design, installation, commissioning, use and maintenance

IEC 60695-11-20:2015 Fire hazard testing - Part 11-20: Test flames - 500 W flame test method
EN 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
EN 60068-2-42:2003 Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections
IEC 60068-2-27:2008 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
EN 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
EN 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
EN 60068-1:2014 Environmental testing - Part 1: General and guidance
EN 60068-2-27:2009 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
EN 61672-1:2013 Electroacoustics - Sound level meters - Part 1: Specifications
EN ISO 9001:2015 Quality management systems - Requirements (ISO 9001:2015)
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
IEC 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 60695-11-10:2013 Fire hazard testing - Part 11-10: Test flames - 50 W horizontal and vertical flame test methods
ISO 9001:2015 Quality management systems — Requirements
IEC 60068-2-42:2003 Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections
EN 60068-2-78:2013 Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
EN 60068-2-6:2008 Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
IEC 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
EN 50130-4:2011/A1:2014 ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS
EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
EN 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
EN 54-1:2011 Fire detection and fire alarm systems - Part 1: Introduction
IEC 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)

View more information
$206.36
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more