Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

UNE-EN 62115:2006

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Electric toys - Safety (IEC 62115:2003 + A1:2004, modified)
Available format(s)

Hardcopy , PDF

Superseded date

07-07-2021

Published date

18-10-2006

Committee
CTN 213/SC 61
DevelopmentNote
Supersedes UNE EN 50088. (01/2008)
DocumentType
Standard
Pages
42
ProductNote
NEW CHILD IS 1 2011 IS NOW ADDED
PublisherName
Asociacion Espanola de Normalizacion
Status
Superseded
SupersededBy
Supersedes

EN 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
EN 61558-2-16:2009/A1:2013 SAFETY OF TRANSFORMERS, REACTORS, POWER SUPPLY UNITS AND SIMILAR PRODUCTS FOR SUPPLY VOLTAGES UP TO 1 100 V - PART 2-16: PARTICULAR REQUIREMENTS AND TESTS FOR SWITCH MODE POWER SUPPLY UNITS AND TRANSFORMERS FOR SWITCH MODE POWER SUPPLY UNITS (IEC 61558-2-16:2009/A1:2013)
EN 60825-1:2014/AC:2017-06 SAFETY OF LASER PRODUCTS - PART 1: EQUIPMENT CLASSIFICATION AND REQUIREMENTS (IEC 60825-1:2014)
IEC 61000-4-4 : 3.0EN+(REDLINE+VERSION) ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST
EN 61000-4-11:2004/A1:2017 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017)
EN 60695-10-2:2014 Fire hazard testing - Part 10-2: Abnormal heat - Ball pressure test method
IEC 61000-4-11:2004+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
EN 60738-1:2006/A1:2009 THERMISTORS - DIRECTLY HEATED POSITIVE TEMPERATURE COEFFICIENT - PART 1: GENERIC SPECIFICATION
IEC 61558-2-16:2009+AMD1:2013 CSV Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-16: Particularrequirements and tests for switch mode power supply units andtransformers for switch mode power supply units
IEC 61000-4-4:2012 RLV Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
EN 61000-4-2:2009 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61558-2-6:2009 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers
EN 60335-2-29:2004/A2:2010 HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 2-29: PARTICULAR REQUIREMENTS FOR BATTERY CHARGERS
IEC 61000-4-6 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS
IEC 61000-4-6:2013 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
EN 61000-4-3 : 2006 AMD 2 2010 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST
EN 60695-2-13:2010/A1:2014 FIRE HAZARD TESTING - PART 2-13: GLOWING/HOT-WIRE BASED TEST METHODS - GLOW-WIRE IGNITION TEMPERATURE (GWIT) TEST METHOD FOR MATERIALS (IEC 60695-2-13:2010/A1:2014)
EN 62233:2008/corrigendum Aug. 2008 MEASUREMENT METHODS FOR ELECTROMAGNETIC FIELDS OF HOUSEHOLD APPLIANCES AND SIMILAR APPARATUS WITH REGARD TO HUMAN EXPOSURE
EN 71-1:2014 Safety of toys - Part 1: Mechanical and physical properties
EN 61558-2-7:2007 Safety of power transformers, power supplies, reactors and similar products - Part 2-7: Particular requirements and tests for transformers and power supplies for toys
IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
EN 61032:1998 Protection of persons and equipment by enclosures - Probes for verification
EN 60086-2:2016 Primary batteries - Part 2: Physical and electrical specifications
IEC 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
EN 61058-1:2002/A2:2008 SWITCHES FOR APPLIANCES - PART 1: GENERAL REQUIREMENTS
EN 61000-4-4:2012 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012)
EN 61558-2-6:2009 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers
EN 60335-1:2012/A13:2017 HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 1: GENERAL REQUIREMENTS (IEC 60335-1:2010, MODIFIED)
IEC 61180-1:1992 High-voltage test techniques for low voltage equipment - Part 1: Definitions, test and procedure requirements
EN 61000-4-6:2014/AC:2015 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013)
EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
EN 60695-11-5:2017 Fire hazard testing - Part 11-5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance
EN 61000-4-13:2002/A2:2016 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-13: TESTING AND MEASUREMENT TECHNIQUES - HARMONICS AND INTERHARMONICS INCLUDING MAINS SIGNALLING AT A.C. POWER PORT, LOW FREQUENCY IMMUNITY TESTS (IEC 61000-4-13:2002/A2:2015)
IEC 62233:2005 Measurement methods for electromagnetic fields of household appliances and similar apparatus with regard to human exposure
IEC 61000-4-13:2002+AMD1:2009+AMD2:2015 CSV Electromagnetic compatibility (EMC) - Part 4-13: Testing and measurement techniques - Harmonics and interharmonics includingmains signalling at a.c. power port, low frequency immunity tests
EN 61180-1:1994 High-voltage test techniques for low-voltage equipment - Part 1: Definitions, test and procedure requirements
EN 60695-2-11:2014 Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) (IEC 60695-2-11:2014)
EN 60990:2016 Methods of measurement of touch current and protective conductor current

View more information
$147.15
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more