Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

VDE 0636-22 : 1984

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

LOW-VOLTAGE FUSES - PART 22: H.R.C. FUSES; H.R.C. FUSES UP TO 1250 A AND 1000 V A.C. FOR PROTECTION OF EQUIPMENT
Superseded date

01-06-1998

Published date

12-01-2013

1 Anwendungsbereich
2 Begriffe
  2.1 NH-Sicherungsleiste
  2.2 Schlagvorrichtung
  2.3 Schaltzustandsgeber
  2.4 Auslösevorrichtung
  2.5 Einschwenk- oder Einsetzvorrichtung
  2.6 Grifflaschen
  2.7 Bemessungsstrom
3 Betriebsbedingungen
4 Klassifikation
5 Charakteristische Merkmale
  5.1 Spannungen
  5.2 Ströme
  5.3 Kennlinien
  5.4 Selektivität
  5.5 Kennlinienbeständigkeit
  5.6 Erwärmung und Verlustleistung
  5.7 Ausschaltvermögen
6 Anforderungen
  6.1 Allgemeines
  6.2 Unverwechselbarkeit
  6.3 Berührungsschutz
  6.4 Kriech-, Luftstrecken und Abstände
  6.5 Leiteranschlüsse
  6.6 NH-Sicherungsunterteile bzw NH-Sicherungsleisten
  6.7 Sicherungseinsätze
  6.8 Kontaktstücke
  6.9 Werkstoffe
  6.10 Isolierteile
  6.11 Kennzeichnung
7 Prüfung
  7.1 Allgemeines
  7.2 Masse, Kennzeichnung, Kriech- und Luftstrecken,
       Abstände
  7.3 Kriechstromfestigkeit
  7.4 Spannungsfestigkeit und Isolationswiderstand
  7.5 Erwärmung und Verlustleistung
  7.6 Zeit/Strom-Verhalten
  7.7 Kennlinienbeständigkeit
  7.8 Wärme-, Schlagfestigkeit und Feuersicherheit
  7.9 Widerstandsfähigkeit gegen Korrosion (Rost)
  7.10 Mechanische Festigkeit und Montierbarkeit
  7.11 Ausschaltvermögen und Schaltspannung
  7.12 Selektivität
  7.13 Funktion des Anzeigers und der Schlagvorrichtung
  7.14 Alterungsbeständigkeit der Kontakte
  7.15 Dynamische Kurzschlussfestigkeit von
       NH-Sicherungsunterteilen und NH-Sicherungsleisten
  7.16 Alterungsbeständigkeit von Leiteranschlussklemmen an
       NH-Sicherungsunterteilen und NH-Sicherungsleisten
Bilder
Zitierte Normen und andere Unterlagen
Erläuterungen

DocumentType
Standard
PublisherName
Verband Deutscher Elektrotechniker
Status
Superseded
SupersededBy

Standards Relationship
DIN 57636-22 : 1984 Corresponds

DIN VDE 0636-41 : 1983 LOW-VOLTAGE FUSES - PART 41: D0-SYSTEM; PROTECTION OF CABLES AND CORDS UP TO 100 A AND 380 V A.C. 250 V D.C.
DIN 57636-21 : 1984 LOW-VOLTAGE FUSES - PART 21: H.R.C. FUSES; PROTECTION OF CABLES AND CORDS UP TO 1250 A AND 500 V A.C., 440 V D.C. AND 660 V A.C.
DIN 57636-1 : 1983 LOW-VOLTAGES FUSES - PART 1: GENERAL REQUIREMENTS
DIN 57636-31 : 1983 LOW VOLTAGE FUSES - PART 31: D-SYSTEM; PROTECTION OF CABLES AND CORDS UP TO 100 A AND 500 V AND/OR UP TO 63 A 660 V A.C. 600 V D.C.
DIN 57636-41 : 1983 LOW-VOLTAGE FUSES - PART 41: D0-SYSTEM; PROTECTION OF CABLES AND CORDS UP TO 100 A AND 380 V A.C. 250 V D.C.
DIN VDE 0636-1 : 1983 LOW-VOLTAGES FUSES - PART 1: GENERAL REQUIREMENTS
DIN 43620-1:1984-05 LOW VOLTAGE HIGH RUPTURING CAPACITY FUSES WITH BLADE CONTACTS; LV HRC FUSE LINKS FOR 500 & 660 V A.C. & 440 V D.C.
DIN 43620-3:1984-05 LOW-VOLTAGE, HIGH-RUPTURING-CAPACITY FUSES WITH BLADE CONTACTS; LV HRC FUSE BASES FOR LV HRC FUSE LINKS FOR 500 AND 660 V A.C. AND 440 V D.C.

DIN 931-1:1987-09 M 1,6 TO M 39 HEXAGON HEAD BOLTS - PRODUCT GRADES A AND B
DIN 42523:1987-05 TRANSFORMERS - ENCAPSULATED-WINDING DRY-TYPE TRANSFORMERS - 50 HZ, 100 TO 2500 KVA
DIN 42500:1984-09 THREE-PHASE OIL-IMMERSED PUBLIC DISTRIBUTION TRANSFORMERS 50 HZ, FROM 50 TO 2500 KVA, U[M] = 24 KV
DIN IEC 60068-2-3:1986-12 ELECTRICAL ENGINEERING; BASIC ENVIRONMENTAL TESTING PROCEDURES; TESTS; TEST CA: DAMP HEAT, STEADY STATE
DIN 43623:1981-05 THREE-POLE FUSE-BASE RACKS 660 V, 100 TO 630 A, FOR L.V.H.R.C. FUSES, FOR BUSBAR MOUNTING
DIN 267-11:1980-01 FASTENERS - TECHNICAL DELIVERY CONDITIONS (WITH ADDITIONS TO ISO 3506) - CORROSION-RESISTANT STAINLESS STEEL FASTENERS
DIN 53480 : 1976 VDE-BESTIMMUNG FUER ELEKTRISCHE PRUEFUNGEN VON ISOLIERSTOFFEN; KRIECHSTROMFESTIGKEIT
DIN 57636-31 : 1983 LOW VOLTAGE FUSES - PART 31: D-SYSTEM; PROTECTION OF CABLES AND CORDS UP TO 100 A AND 500 V AND/OR UP TO 63 A 660 V A.C. 600 V D.C.
DIN 57636-23 : 1984 NIEDERSPANNUNGSSICHERUNGEN; NH-SYSTEM, HALBLEITERSCHUTZSICHERUNGEN BIS 1600 A UND BIS 3000 V
DIN 43620-4:1981-09 LOW VOLTAGE HIGH-RUPTURING-CAPACITY FUSES WITH BLADE CONTACTS 500 AND 660 V A.C. AND 440 D.C. - REPLACEMENT HANDLE FOR THE SIZES 00 UP TO 3 - DIMENSIONS OF THE ENGAGING PART
DIN 42524:1987-05 TRANSFORMERS - NON-ENCAPSULATED-WINDING DRY-TYPE TRANSFORMERS - 50 HZ, 100 TO 1600 KVA
DIN 57636-41 : 1983 LOW-VOLTAGE FUSES - PART 41: D0-SYSTEM; PROTECTION OF CABLES AND CORDS UP TO 100 A AND 380 V A.C. 250 V D.C.
DIN 46206-2:1971-06 SUPPLY-TERMINALS FOR ELECTRICAL EQUIPMENT >= 40 A, CONNECTIONS WITH RECTANGULAR CROSS-SECTION, BASIC DIMENSIONS AND COORDINATION
DIN 43620-1:1984-05 LOW VOLTAGE HIGH RUPTURING CAPACITY FUSES WITH BLADE CONTACTS; LV HRC FUSE LINKS FOR 500 & 660 V A.C. & 440 V D.C.
DIN 43620-3:1984-05 LOW-VOLTAGE, HIGH-RUPTURING-CAPACITY FUSES WITH BLADE CONTACTS; LV HRC FUSE BASES FOR LV HRC FUSE LINKS FOR 500 AND 660 V A.C. AND 440 V D.C.
DIN 933:1987-09 M 1.6 TO M 52 HEXAGON HEAD SCREWS THREADED UP TO THE HEAD; PRODUCT GRADES A & B
DIN 50018:2013-05 Testing in a saturated atmosphere in the presence of sulfur dioxide
DIN 57471-2 : 1975 VDE SPECIFICATIONS FOR FIRE RISK TESTING OF ELECTROTECHNICAL PRODUCTS, THEIR SUBASSEMBLIES AND COMPONENTS - GLOW-WIRE TEST
DIN 57636-1 : 1983 LOW-VOLTAGES FUSES - PART 1: GENERAL REQUIREMENTS

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more