• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

01/208272 DC : DRAFT NOV 2001

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

EN 50CCC-1 - GENERIC STANDARD TO DEMONSTRATE THE COMPLIANCE OF ELECTRONIC AND ELECTRICAL APPARATUS WITH THE BASIC RESTRICTIONS RELATED TO HUMAN EXPOSURE TO ELECTROMAGNETIC FIELDS (0 HZ - 300 GHZ)
Superseded date

18-02-2004

Published date

23-11-2012

1 Scope
2 Normative references
3 Terms, definitions
   3.1 Terms and definitions
4 Compliance criteria
5 Assessment methods
6 Evaluation of compliance to limits
7 Applicability of compliance assessments methods
   7.1 Characteristics and parameters of apparatus
        to be considered
   7.2 List of possible assessment methods
   7.3 Decision tree (Assessment applicability table
        versus equipment characteristics)
8 Sources with multiple frequencies
   8.1 Harmonics, pulses and non-sinusoidal fields
9 Assessment report
   9.1 General
   9.2 Items to be recorded in the assessment report
10 Information to be supplied with the apparatus
Annex A Field calculation (informative)
      A.1 Purpose
      A.2 Far-field region
      A.3 Radiating near-field region
      A.4 Reactive near-field region
      A.5 Example of calculations within field regions at
          900 MHz
Annex B Simulation with/without phantom SAR measurement
(informative)
      B.1 Whole body SAR measurement
      B.2 Localised SAR measurement
Annex C Information for Numerical Modelling (informative)
      C.1 Introduction
      C.2 Anatomical Models
      C.3 Simpler, homogeneous body models
      C.4 Electrical properties of tissue
      C.5 Calculation of the induced electric current
          density
      C.6 Representation of measured magnetic field
          distributions by equivalent sources
      C.7 Induced current densities for different sizes
          of prolate spheroid
      C.8 Induced current densities for the human body
          and hand (informative)
      C.9 References
Annex D Measurements of physical properties and body
currents (informative)
      D.1 Measurement of body current
      D.2 Measurement of induced body currents
      D.3 Measurement of contact current
      D.4 Measurement of touch voltage
Annex E SAR (informative)
      E.1 Specific Absorption Rate (SAR) measurement
          procedures
Annex F Measurement of E and H field (informative)
      F.1 Measurement of external electromagnetic fields
Annex G Source modelling (informative)
      G.1 Numerical modelling
      G.2 Field strength calculations
      G.3 Specific absorption rate calculations

EN 50CCC-1

Committee
GEL/106
DocumentType
Draft
PublisherName
British Standards Institution
Status
Superseded
SupersededBy

ES 59005 : 98 CORR 98 CONSIDERATIONS FOR EVALUATION OF HUMAN EXPOSURE TO ELECTROMAGNETIC FIELDS (EMFS) FROM MOBILE TELECOMMUNICATION EQUIPMENT (MTE) IN THE FREQUENCY RANGE 30 MHZ - 6 GHZ
ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories
EN 50361:2001 Basic standard for the measurement of Specific Absorption Rate related to human exposure to electromagnetic fields from mobile phones (300 MHz - 3 GHz)
EN 50360:2017 Product standard to demonstrate the compliance of wireless communication devices, with the basic restrictions and exposure limit values related to human exposure to electromagnetic fields in the frequency range from 300 MHz to 6 GHz: devices used next to the ear
PREN 50366 : DRAFT 2000 MEASURING METHODS FOR DETERMINING THE MAGNETIC FLUX DENSITY IN THE SPACE AROUND HOUSEHOLD AND SIMILAR APPLIANCES WITH PARTICULAR REGARD TO HUMAN EXPOSURE
EN 50357:2001 Evaluation of human exposure to electromagnetic fields from devices used in Electronic Article Surveillance (EAS), Radio Frequency Identification (RFID) and similar applications
IEC 61786:1998 Measurement of low-frequency magnetic and electric fields with regard to exposure of human beings - Special requirements for instruments and guidance for measurements
EN 50371:2002 Generic standard to demonstrate the compliance of low power electronic and electrical apparatus with the basic restrictions related to human exposure to electromagnetic fields (10 MHz - 300 GHz) - General public

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.