• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

ANSI Z21.60-2017/CSA 2.26-2017

Current
Current

The latest, up-to-date edition.

Decorative gas appliances for installation in solid-fuel burning fireplaces
Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

01-01-2017

Preface
1 Scope
2 Reference publications
3 Definitions
4 Construction
5 Performance
6 Manufacturing and production tests
7 Items unique to the United States
8 Items unique to Canada
Annex A (normative) - Outline of lighting instructions for
        appliances equipped with continuous pilots
Annex B (normative) - Outline of operating instructions for
        appliances equipped with intermittent pilot or
        interrupted pilot systems
Annex C (normative) - Outline of operating instructions for
        appliances equipped with direct ignition systems
Annex D (normative) - Provisions for listed gas appliance
        conversion kits (optional)
Annex E (informative) - Pertinent references to ANSI Y14.15
Annex F (informative) - Wire color designations
Annex G (informative) - Recommended wire color usage
Annex H (informative) - Preferred graphic symbols of
        commonly used items, extracted from the
        Standard for Graphic Symbols for Electrical
        and Electronics Diagrams, ANSI/ IEEE 315,
        and abbreviations for these items
Annex I (informative) - Table of conversion factors

Pertains to decorative gas appliances for installation in solid-fuel burning fireplaces, hereinafter referred to as appliances, which are constructed entirely of new, unused parts and materials, and having input ratings up to and including 400,000 Btu/hr (117228 W).

Preface This is the fourth edition of ANSI Z21.60/CSA 2.26, Decorative gas appliances for installation in solid- fuel burning fireplaces. It supersedes the previous editions published in 2012, 2003, and 1996. Scope 1.1 This Standard applies to decorative gas appliances for installation in solid-fuel burning fireplaces, (see Clause 3, Definitions), hereinafter referred to as appliances, which are constructed entirely of new, unused parts and materials, and having input ratings up to and including 400,000 Btu/hr (117 228 W). These appliances are: a) for use with natural gas; b) for use with propane gas; c) for use with natural and convertible for use with propane gas (see Clause 3, Definitions); d) for manufactured home (U.S. only) or mobile home installation for use with natural and convertible for use with propane gas; and e) for manufactured home (U.S. only) or mobile home installation for use with propane gas only. The construction of decorative appliances for installation in solid-fuel burning fireplaces for use with the above-mentioned gases is covered under Clause 4. The performance of decorative appliances for installation in solid-fuel burning fireplaces for use with the above-mentioned gases is covered under Clause 5. 1.2 Decorative appliances for installation in solid-fuel burning fireplaces are not thermostatically controlled. 1.3 This Standard does not cover unvented room heaters. 1.4 The use of the term \"appliance\" henceforth in this Standard is in reference to a decorative gas appliance for installation in a solid-fuel burning fireplace. 1.5 If a value for measurement as given in this Standard is followed by an equivalent value in other units, the first stated value is to be regarded as the specification. (Also see Clause 8.3.) 1.6 All references to psi throughout this Standard are to be considered gage pressure unless otherwise specified. 1.7 Clause 7, Items unique to the United States, contains provisions that are unique to the United States. 1.8 Clause 8, Items unique to Canada, contains provisions that are unique to Canada. 1.9 Special construction provisions applicable to an appliance designed for use with an optional listed conversion kit are outlined under Annex D, Provisions for listed gas appliances conversion kits (optional). 1.10 Clause 2 contains a list of standards specifically referenced in this Standard and sources from which they may be obtained. Clause 2 includes both U.S. and Canadian reference standards where applicable. It is the responsibility of the user of this Standard to determine which referenced standard applies based on the requirements of the authority having jurisdiction at the location of the installation.

DevelopmentNote
Also numbered as CSA 2.26. (10/2001) Effective in Canada August 1, 2018. (02/2017)
DocumentType
Standard
ISBN
978-1-4883-0685-3
Pages
0
PublisherName
Canadian Standards Association
Status
Current
Supersedes

ANSI Z21.21 : 2015 AUTOMATIC VALVES FOR GAS APPLIANCES
C22.1-15 Canadian Electrical Code, Part I (23rd Edition), Safety Standard for Electrical Installations
CSA C22.2 No. 49 : 2014 FLEXIBLE CORDS AND CABLES
CSA Z234.1 : 0 METRIC PRACTICE GUIDE
CSA 6.5 : 2015 AUTOMATIC VALVES FOR GAS APPLIANCES
CSA B78.4 : 1979 ELECTRIC AND ELECTRONICS DIAGRAMS
NFPA 501A : 2017 FIRE SAFETY CRITERIA FOR MANUFACTURED HOME INSTALLATIONS, SITES, AND COMMUNITIES
IEEE/ASTM SI_10-2010 American National Standard for Metric Practice
IEEE 315 : 1975 GRAPHIC SYMBOLS FOR ELECTRICAL AND ELECTRONICS DIAGRAMS (INCLUDING REFERENCE DESIGNATION LETTERS)
CSA 6.10 : 2015 CONNECTORS FOR GAS APPLIANCES
NFPA 70 : 2017 NATIONAL ELECTRICAL CODE
UL 372:6ED 2007-07 Automatic Electrical Controls for Household and Similar Use - Part 2: Particular Requirements for Burner Ignition Systems and Components
CSA Z240 MH SERIES : 2016 MANUFACTURED HOMES
ANSI C101.1 : 1992 LEAKAGE CURRENT FOR APPLIANCES
NCSBCS A225.1 : 1994 MANUFACTURED HOME INSTALLATIONS
NFPA 54 : 2018 NATIONAL FUEL GAS CODE
ANSI Z223.1 : 2018 NATIONAL FUEL GAS CODE
ANSI Z21.24 : 2015 CONNECTORS FOR GAS APPLIANCES

View more information
£308.89
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.