AS 1316-1972

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Masonry cement (metric units)
Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

30-06-2017

Language(s)

English

Published date

01-01-1972

Preview

1 - AS 1316-1972 MASONRY CEMENT
4 - PREFACE
5 - CONTENTS
6 - FOREWORD
7 - PART I -SPECIFICATION
7 - 1 SCOPE.
7 - 2 DEFINITIONS.
7 - 2.1 Masonry Cement
7 - 2.2 Mortar
7 - 3 PHYSICAL REQUIREMENTS.
7 - 4 PACKING AND MARKING.
7 - 5 DELIVERY AND INSPECTION.
7 - 6 SAMPLING.
8 - 7 TESTING.
9 - PART II -METHODS OF TEST
9 - SECTION 1. GENERAL
9 - 1.1 TEST ROOM.
9 - 1.2 MOIST CUPBOARDS.
9 - 1.3 MATERIALS.
9 - 1.4 APPARATUS AND EQUIPMENT.
9 - 1.5 STANDARD SAND.
9 - 1.5.1 General.
9 - 1.5.2 Graded Sand.
10 - 1.5.3 600-850 um Sand
11 - SECTION 2. DETERMINATION OF SETTING TIME
11 - 2.1 APPARATUS.
11 - 2.2 PREPARATION OF PASTE.
11 - 2.3 TEST PROCEDURE.
11 - 2.3.1 Normal Consistency.
11 - 2.3.2 Setting Time.
13 - SECTION 3. DETERMINATION OF AUTOCLAVE EXPANSION
13 - 3.1 APPARATUS.
13 - 3.2 PREPARATION OF PASTE.
13 - 3.3 NUMBER OF TEST SPECIMENS.
13 - 3.4 PREPARATION OF TEST SPECIMENS.
13 - 3.4.1 Preparation of Moulds.
13 - 3.4.2 Moulding Specimens.
13 - 3.4.3 Storage of Test Specimens.
14 - 3.5 TEST PROCEDURE.
14 - 3.6 CALCULATION.
14 - 3.7 RETESTS.
15 - SECTION 4. DETERMINATION OF WATER RETENTIVITY VALUE
15 - 4.1 APPARATUS.
15 - 4.2 PREPARATION OF MORTAR.
16 - 4.3 DETERMINATION OF FLOW.
16 - 4.4 TEST PROCEDURE.
17 - 4.5 CALCULATION.
18 - SECTION 5. DETERMINATION OF AIR CONTENT
18 - 5.1 APPARATUS.
18 - 5.2 PREPARATION OF MORTAR.
18 - 5.3 TEST PROCEDURE.
19 - 5.4 CALCULATION.
20 - SECTION 6. DETERMINATION OF COMPRESSIVE STRENGTH
20 - 6.1 APPARATUS.
20 - 6.2 PREPARATION OF MORTAR.
20 - 6.3 NUMBER OF TEST SPECIMENS.
20 - 6.4 MOULDING TEST SPECIMENS.
21 - 6.5 STORAGE OF TEST SPECIMENS.
21 - 6.6 TEST PROCEDURE.
22 - 6.7 CALCULATION.
22 - 6.8 FAULTY SPECIMENS AND RETESTS.
23 - APPENDIX A - AUTOCLAVE
23 - A1 DESCRIPTION.
23 - A2 DESIGN.
23 - A3 SAFETY PRECAUTIONS.
23 - A3.1 Pressure Gauge.
23 - A3.2 Testing of Gauge.
24 - A3.3 Automatic Control.
24 - A3.4 Setting of Safety Valve.
24 - A3.5 Avoidance of Burning.
24 - A3.6 Continuing Pressure.
24 - A3.7 Maintenance of Vent Valve.
25 - APPENDIX B - BAR MOULDS
27 - APPENDIX C - CUBE MOULDS
28 - APPENDIX D - FLOW TABLE AND FLOW MOULD
28 - D1 FLOW TABLE AND FRAME.
29 - D2 FLOW TABLE MOUNTING.
29 - D3 FLOW TABLE LUBRICATION.
30 - D4 MOULD AND CALIPER
30 - APPENDIX E - GRADUATED GLASS CYLINDERS
30 - E1 CAPACITIES.
30 - E2 ORDER OF ACCURACY.
31 - APPENDIX F - LENGTH COMPARATOR
31 - F1 DESCRIPTION.
31 - F2 REFERENCE BAR.
31 - F3 CHECKS
33 - APPENDIX G - TAMPER
33 - APPENDIX H - WATER RETENTION APPARATUS
33 - APPENDIX J - MEASURE

Sets down the minimum requirements for masonry cement intended for use in mortars in masonry construction and in rendering and plastering masonry and other surfaces.

This specification sets down minimum requirements for a hydraulic cement (known as "masonry cement") intended for use in mortars in masonry construction and in rendering and plastering masonry and other surfaces. The specification does not purport to provide for all the requirements of a cement intended for use in special purpose mortars, eg. high strength mortars and grouts.

Committee
BD-010
DocumentType
Standard
ISBN
0 7262 4657 3
Pages
28
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes

Under Revision see DR 98633

AS 3700 SUPP 4-1992 Masonry in buildings (known as the SAA Masonry Code) - Extracts from AS 3700 - Masonry construction requirements (Supplement to AS 3700-1988)
AS 3700 SUPP 5-1992 Masonry in buildings (known as the SAA Masonry Code) - Extracts from AS 3700 - Masonry housing requirements (Supplement to AS 3700-1988)
AS 2050-1995 Installation of roof tiles
AS 3700 SUPP 3-1992 Masonry in buildings (known as the SAA Masonry Code) - Extracts from AS 3700 - Masonry materials requirements (Supplement to AS 3700-1988)
AS 3700-1998 Masonry structures
AS 3700-2001 Masonry structures
AS 4597-1999 Installation of roof slates and shingles (Non-interlocking type) (Reconfirmed 2015)
AS 2701-2001 Methods of sampling and testing mortar for masonry construction (Reconfirmed 2015)

View more information
£29.14
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.