We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
  • AS 1531-1991

    Current The latest, up-to-date edition.
    Add to Watchlist
    This Standard has been added successfully to your Watchlist.
    Please visit My Watchlist to see all standards that you are watching.
    Please log in or to add this standard to your Watchlist.
    We could not add this standard to your Watchlist.
    Please retry or contact support for assistance.
    You need to be logged in to add this standard to your Watchlist.
    Please log in now or create an account to add.
    You already added this Product in the Watchlist.

    Conductors - Bare overhead - Aluminium and aluminium alloy (Reconfirmed 2016)

    Available format(s):  Hardcopy, PDF 1 User, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Language(s):  English

    Published date:  10-06-1991

    Publisher:  Standards Australia

    Add to Watchlist

    Add To Cart

    Abstract - (Show below) - (Hide below)

    Sets out requirements and tests necessary for homogeneous bare electrical conductors for overhead power transmission and constructed of all aluminium and aluminium alloy wires. A range of wire sizes, 2.50mm to 4.75mm, and their properties are provided.

    Scope - (Show below) - (Hide below)

    This Standard specifies requirements and tests for homogeneous bare electrical conductors for overhead power transmission, and constructed of all aluminium or all aluminium alloy wires.NOTES:1 Appendix A gives methods to calculate conductor properties.2 Appendix B gives the coefficient of linear expansion and the theoretical basis for the calculation of modulus of elasticity.3 Appendix C lists code names which may be used to refer to specific type and construction of conductor.4 Appendix D lists information which should be supplied with enquiries and orders for conductors.

    General Product Information - (Show below) - (Hide below)

    Committee EL/10
    Document Type Standard
    Product Note Reconfirmed 27/05/2016.This standard has been reconfirmed in Australia in 2016 and remains current in New Zealand. Reconfirmation Notice 27/05/2016
    Publisher Standards Australia
    Status Current
    Supersedes

    History - (Show below) - (Hide below)

    First published as part of AS C75-1936 (endorsement of BS 215-1934 without amendment) AS C75-1936 revised and redesignated in part as AS C75.2-1965.Revised and redesignated AS 1531.1-1974.AS C75.3 first published 1965.Revised and redesignated AS 1531.2-1974.AS 1531.3 first published 1984.AS 1531.1-1974, AS 1531.2-1974 and AS 1531.3-1984 revised, amalgamated and redesignated AS 1531-1991.Reconfirmed 2016. AS 1531 first published as part of AS C75-1936 (endorsement of BS 215-1932 without amendment). AS C75-1936 revised and redesignated in part as AS C75.2-1965. Revised and redesignated AS 1531.1-1974. AS C75.3 first published 1965. Revised and redesignated AS 1531.2-1974. AS 1531.3 first published 1984. AS 1531.1-1974, AS 1531.2-1974 and AS 1531.3-1984 revised, amalgamated and redesignated AS 1531-1991.

    Standards Referenced By This Book - (Show below) - (Hide below)

    AS 2857-1986 Timber drums for insulated electric cables and bare conductors
    AS/NZS 2857:1996 Timber drums for insulated electric cables and bare conductors
    AS 2505.5-2002 Metallic materials Wire - Simple torsion test
    AS C365.2-1970 Drums for bare stranded conductors - Metal drums
    AS 2848.1-1998 Aluminium and aluminium alloys - Compositions and designations Wrought products (Reconfirmed 2018)
    AS 1391-1991 Methods for tensile testing of metals
    AS 1391-2007 Metallic materials - Tensile testing at ambient temperature
    AS 2505.5-1982 Methods for bend and related testing of metals - Torsion and wrapping tests on wire

    Standards Referencing This Book - (Show below) - (Hide below)

    AS/NZS 3599.2:1999 Electric cables - Aerial bundled - Polymeric insulated - Voltages 6.35/11(12) kV and 12.7/22(24) kV Non-metallic screened
    AS 3822(INT)-1998 Test methods for bare overhead conductors
    AS/NZS 1768:2007 Lightning protection
    AS/NZS 7000:2016 Overhead line design
    AS/NZS 3008.1.1:2017 Electrical installations - Selection of cables Cables for alternating voltages up to and including 0.6/1 kV - Typical Australian installation conditions
    AS 3822-2002 Test methods for bare overhead conductors
    HB 331-2012 Overhead line design
    AS/NZS 3008.1.2:2010 Electrical installations - Selection of cables
    DR 00391 Conductors - Covered overhead - For working voltages 6.35/11(12)kV up to and including 19/33(36)kV
    AS/NZS 3008.1.2:1998 Electrical installations - Selection of cables - Cables for alternating voltages up to and including 0.6/1 kV - Typical New Zealand installation conditions
    AS/NZS 7000:2010 Overhead line design - Detailed procedures
    AS/NZS 3008.1.1:2009 Electrical installations - Selection of cables
    AS/NZS 3675:2002 Conductors - Covered overhead - For working voltages 6.35/11 (12) kV up to and including 19/33 (36) kV (Reconfirmed 2017)
    AS/NZS 3008.1.1:1998 Electrical installations - Selection of cables - Cables for alternating voltages up to and including 0.6/1 kV - Typical Australian installation conditions
    AS/NZS 3008.1.2:2017 Electrical installations - Selection of cables Cables for alternating voltages up to and including 0.6/1 kV - Typical New Zealand conditions
    AS 3675-1993 Conductors - Covered overhead - For working voltages 6.35/11 kV up to and including 19/33 kV
    AS/NZS 1768(INT):2003 Lightning protection
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective