1 - AS 3205-1985 APPROVAL AND TEST SPECIFICATION-DENTAL AND MOBILE DIAGNOSTIC X-RAY EQUIPMENT
3 - PREFACE
4 - CONTENTS
5 - SECTION 1. SCOPE, APPLICATION AND REFERENCED DOCUMENTS
5 - 1.1 SCOPE.
5 - 1.2 APPLICATION.
5 - 1.2.1 Compliance with AS 3100, and AS 3200.
5 - 1.2.2 Special requirements.
5 - 1.3 REFERENCED DOCUMENTS.
5 - 1.3.1 Standards
5 - 1.3.2 Approval and Test Specifications:
6 - SECTION 2. DEFINITIONS
6 - 2.2 GENERAL DEFINITIONS.
6 - 2.2.100 Coefficient of variation (C)
6 - 2.2.101 Collimators.
6 - 2.2.102 Documents.
6 - 2.2.103 Exposure
6 - 2.2.104 Exposure factors.
6 - 2.2.105 Filtration.
6 - 2.2.106 Radi ation.
7 - 2.2.107 Shall and should
7 - 2.2.108 Shielding.
7 - 2.2.109 X-ray.
8 - SECTION 3. GENERAL REQUIREMENTS
8 - 3.1 DESIGN AND CONSTRUCTION.
8 - 3.1.1 General.
8 - 3.1.100 Mechanical requirements.
8 - 3.1.101 Hydraulic and pneumatic power.
8 - 3.1.102 Battery-powered mobile X-ray equipment.
8 - 3.1.103 Stops and brakes.
8 - 3.1.104 X-ray tube housing (See also Clause 8.1).
8 - 3.1.105 High voltage equipment.
9 - 3.1.106 Circuit protection.
9 - 3.3 MECHANICAL STABILITY (OTHER THAN FIXED EQUIPMENT).
9 - 3.3.1 General.
9 - 3.6 CONTROLS, INSTRUMENTS AND INDICATORS.
9 - 3.6.1 Arrangements.
9 - 3.6.5 Accuracy of output controls and instruments.
9 - 3.6.8 Limitation of movement.
9 - 3.6.100 Indication of exposure factors for radiography.
9 - 3.6.101 Tube current.
9 - 3.6.102 Quantity of electricity.
9 - 3.6.103 Supply indicator.
9 - 3.6.104 ‘Beam On’ indi cation.
10 - 3.6.105 Exposure switch.
10 - 3.6.106 Automatic exposure factors.
10 - 3.6.107 Timers.
10 - 3.6.108 Capacitor-discharge X-ray equipment.
10 - 3.6.109 Reliability of X-ray output performance.
11 - 3.7 ENCLOSURE AND LOCATION OF BATTERIES.
11 - 3.9 SUSPENDED MASSES.
11 - 3.9.1 General.
11 - 3.9.2 Inspection ports.
11 - 3.9.3 Locking devices.
12 - SECTION 4. PROTECTION AGAINST MECHANICAL AND ELECTRICAL FAILURE
13 - SECTION 5. PROTECTION AGAINST ELECTRIC SHOCK HAZARDS
14 - SECTION 6. PROTECTION AGAINST HEAT AND FIRE
15 - SECTION 7. EQUIPMENT MARKING AND ACCOMPANYING DOCUMENTS
15 - 7.1 MARKING ON EQUIPMENT.
15 - 7.1.1 General.
15 - 7.1.100 Protective devices.
15 - 7.1.101 X-ray tube assemblies.
15 - 7.1.102 Light beam collimator.
16 - SECTION 8. PROTECTION AGAINST RADIATION
16 - 8.1 X-RAY TUBE, X-RAY TUBE HOUSING, X-RAY TUBE ASSEMBLY AND COLLIMATOR DEVICES.
16 - 8.1.1 Primary limitation of the X-ray beam.
16 - 8.1.2 Radiation protection of X-ray tube assembly.
16 - 8.2 LEAKAGE RADIATION FROM CAPACITOR-DISCHARGE X-RAY EQUIPMENT.
16 - 8.3 BEAM QUALITY.
16 - 8.3.1 Dental X-ray equipment designed for use with intra-oral image receptors.
16 - 8.3.2 Filtration of all other X-ray equipment except equipment incorporating intra-oral X-ray sources used in conjunction...
16 - 8.3.3 Determination of beam quality.
16 - 8.3.4 Determination of beam quality for capacitor discharge X-ray equipment.
16 - 8.4 FIELD LIMITATIONS OF DENTAL X-RAY EQUIPMENT
17 - 8.4.1 Extra-oral sources with intra-oral image receptors.
17 - 8.4.2 Intra-oral X-ray sources used in conjunction with extra-oral image receptors
17 - 8.4.3 X-ray equipment used for dental panoramic tomography.
17 - 8.4.4 X-ray equipment for cephalometric radiography.
17 - 8.5 MOBILE OR PORTABLE DIAGNOSTIC X-RAY EQUIPMENT.
17 - 8.5.1 General.
17 - 8.5.2 Limitation of focus-skin distance.
18 - 8.5.3 Light beam collimator.
18 - 8.5.4 Interlocking of filters.
18 - 8.5.5 Mobile diagnostic X-ray equipment with image intensifiers.
19 - 8.5.6 Maximum kerma in air rate during fluoroscopy.
20 - APPENDIX A - TEST TO BE APPLIED FOR TYPE APPROVAL

Sets out safety requirements for dental and mobile diagnostic X-ray equipment supplementary to the general requirements for electromedical equipment given in AS 3200, and specifies the protective measures to be taken against the hazards of ionizing radiation. Provisions of the Standard apply to the construction, installation and safeguarding of all dental and mobile X-ray equipment used for diagnostic purposes.

Add the following:This specification sets out the particular safety requirements for dental and mobile diagnostic X-ray equipment as defined in Clause 2.2.The specification also applies to-(a) X-ray equipment for dental panoramic radiography with an intra-oral X-ray source;(b) X-ray equipment for dental panoramic tomography; and(c) cephalometric X-ray equipment.It also specifies the measures to be taken for the provision of protection additional to that incorporated in the X-ray equipment against the hazards of ionizing radiation.

Committee
HE-003
DocumentType
Standard
ISBN
0 7262 3783 3
Pages
16
PublisherName
Standards Australia
Status
Withdrawn
Supersedes

Obsolescent 1993

AS 3208-1988 Approval and test specification - Transformers in electromedical equipment
AS 1169-1982 Minimizing of combustion hazards arising from the medical use of flammable anaesthetic agents
AS 3193-1995 Approval and test specification - Transformer type battery chargers
AS 2398-1980 Fixed diagnostic X-ray equipment - Design, construction and installation - Safety requirements
AS 3200-1986 Approval and test specification - Electromedical equipment - General requirements
AS/NZS 3100:2002 Approval and test specification - General requirements for electrical equipment

AS 3200-1986 Approval and test specification - Electromedical equipment - General requirements
SAA HB37.2-1993 Handbook of Australian fire Standards Electrical equipment (Reconfirmed 2016)

View more information
£40.57
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.