Credit card payment only is accepted for this order because it contains a mix of both publications and training products.
Invalid username/password. Please try again.
Intruder alarm systems Alarm transmission systems (Reconfirmed 2020)
:
Available format(s): Hardcopy, PDF 1 User, PDF 3 Users, PDF 5 Users, PDF 9 Users
Language(s): English
Published date: 30-01-2008
Publisher: Standards Australia
1 - AS/NZS 2201.5:2008 INTRUDER ALARM SYSTEMS - ALARM TRANSMISSION SYSTEMS4 - PREFACE5 - CONTENTS6 - SECTION 1 SCOPE AND GENERAL6 - 1.1 SCOPE6 - 1.2 REFERENCED DOCUMENTS6 - 1.3 DEFINITIONS6 - 1.3.1 Aggregate path classification6 - 1.3.2 Alarm transmission equipment6 - 1.3.3 Alarm transmission system7 - 1.3.4 Alarm transmission system interface7 - 1.3.5 Availability7 - 1.3.6 Communications path7 - 1.3.7 Final alarm receiving interface7 - 1.3.8 Independent path7 - 1.3.9 Poll7 - 1.4 MARKING8 - SECTION 2 ALARM TRANSMISSION EQUIPMENT8 - 2.1 EQUIPMENT REQUIREMENTS8 - 2.1.1 Power supply8 - 2.1.2 Access8 - 2.2 INSTALLATION REQUIREMENTS8 - 2.2.1 Alarm transmission system interface (clients premises)8 - 2.2.2 Electrical supply8 - 2.2.3 Alarm transmission equipment8 - 2.2.4 Final alarm-receiving interface8 - 2.2.5 Installation8 - 2.3 DOCUMENTATION9 - 2.4 TEST REPORT10 - SECTION 3 ALARM TRANSMISSION SYSTEM REQUIREMENTS10 - 3.1 GENERAL11 - 3.2 ALARM TRANSMISSION SYSTEM MODE12 - 3.3 ALARM TRANSMISSION SYSTEM(S) SHARING INFRASTRUCTURE WITH OTHER SYSTEMS12 - 3.4 TRANSMISSION TIME13 - 3.5 ALARM SYSTEM INTERCONNECTION SUPERVISION13 - 3.5.1 Interconnection with the alarm system13 - 3.5.2 Alarm system Class C313 - 3.5.3 Alarm system Class C413 - 3.5.4 Alarm system Class C513 - 3.6 TRANSMISSION SYSTEM SUPERVISION13 - 3.7 TRANSMISSION SYSTEM AVAILABILITY13 - 3.7.1 General14 - 3.7.2 Alarm transmission system availability14 - 3.7.3 Minimum availability requirement14 - 3.7.4 Transmission system management15 - 3.7.5 Multiple independent paths15 - 3.8 SIGNALLING SECURITY15 - 3.8.1 General15 - 3.8.2 Classification16 - 3.9 FAULT AND MAINTENANCE LOG16 - 3.10 TESTING17 - SECTION 4 ALARM TRANSMISSION SYSTEM TESTS17 - 4.1 GENERAL17 - 4.2 SYSTEM CONFIGURATION17 - 4.3 TRANSMISSION TIME-NORMAL PERFORMANCE TEST17 - 4.3.1 Objective of test17 - 4.3.2 Test procedure17 - 4.3.3 Requirement17 - 4.4 TRANSMISSION TIME-RECOVERY FROM OVERLOAD TEST17 - 4.4.1 Objective of test18 - 4.4.2 Test procedure18 - 4.4.3 Requirement18 - 4.5 TRANSMISSION TIME-PEAK LOAD TEST18 - 4.5.1 Objective of test18 - 4.5.2 Test procedure18 - 4.5.3 Requirement18 - 4.6 ALARM SYSTEM INTERCONNECTION SUPERVISION TEST-CATEGORIES T1 AND T218 - 4.6.1 Objective of test19 - 4.6.2 Test procedure19 - 4.6.3 Requirements19 - 4.7 ALARM SYSTEM INTERCONNECTION SUPERVISION TEST-CATEGORY T319 - 4.7.1 Objective of test19 - 4.7.2 Test procedure20 - 4.7.3 Requirements20 - 4.8 ALARM SYSTEM INTERCONNECTION SUPERVISION TEST-CATEGORY T420 - 4.8.1 Objective of test20 - 4.8.2 Test procedure21 - 4.8.3 Requirement21 - 4.9 ALARM SYSTEM INTERCONNECTION SUPERVISION TEST-CATEGORY T521 - 4.9.1 Objective of test21 - 4.9.2 Test procedure21 - 4.9.3 Requirement21 - 4.10 ALARM TRANSMISSION SYSTEM SUPERVISION TEST-CATEGORY T121 - 4.10.1 Objective of test21 - 4.10.2 Test procedure22 - 4.10.3 Requirements22 - 4.11 ALARM TRANSMISSION SYSTEM SUPERVISION TEST-CATEGORY T222 - 4.11.1 Objective of test22 - 4.11.2 Test procedure22 - 4.11.3 Requirements23 - 4.12 ALARM TRANSMISSION SYSTEM SUPERVISION TEST-CATEGORIES T3, T4 AND T523 - 4.12.1 Objective of test23 - 4.12.2 Test procedure23 - 4.12.3 Requirement23 - 4.13 TRANSMISSION SYSTEM AVAILABILITY TEST23 - 4.13.1 Objective of test23 - 4.13.2 Test procedure23 - 4.13.3 Requirement23 - 4.14 SIGNAL SECURITY-CATEGORY S123 - 4.14.1 Objective of test24 - 4.14.2 Test procedure24 - 4.14.3 Requirement24 - 4.15 SIGNAL SECURITY-CATEGORY S224 - 4.15.1 Objective of test24 - 4.15.2 Test procedure24 - 4.15.3 Requirements24 - 4.16 SIGNAL SECURITY-CATEGORY S324 - 4.16.1 Objective of test24 - 4.16.2 Test procedure25 - 4.16.3 Requirements25 - 4.17 SIGNAL SECURITY-CATEGORY S425 - 4.17.1 Objective of test25 - 4.17.2 Test procedure25 - 4.17.3 Requirements26 - 4.18 SIGNAL SECURITY-CATEGORY S526 - 4.18.1 Objective of test26 - 4.18.2 Test procedure26 - 4.18.3 Requirement26 - 4.18.4 Manufacturers validation
Specifies the general requirements for alarm transmission systems, equipment and systems using dedicated paths, switched networks, digital networks and wire-free systems.
This Standard specifies the requirements for the performance, reliability and security characteristics for alarm transmission systems used as part of an intruder alarm system.It includes requirements for the transmission of signals between an intruder alarm system in a clients premises and a monitoring centre.
First published as part of AS 2201.2-1978.Second edition 1986.Revised and redesignated in part as AS 2201.5-1992.Jointly revised and redesignated AS/NZS 2201.5:2008.Reconfirmed 2020. First published as part of AS 2201.2-1978. Second edition 1986. Revised and redesignated in part as AS 2201.5-1992. Jointly revised and redesignated AS/NZS 2201.5:2008.
AUD CAD CHF CNY DKK EUR GBP HKD IDR INR JPY KRW MXN NOK NZD SEK SGD USD ZAR
Unfortunately, this product is not available for purchase in your region.
Features
Learn more on subscription solutions
Get in touch with us
Loading..
A free alerting service to track changes to standards.
Once you've completed your purchase you'll get a link to My Orders on: -the Confirmation page of check out -and by email You'll be able to access your Multi User Orders to add Users.
You have selected more than three (3) participants. Please contact our Customer Service team.
You have already added this product in the cart. If you would like to add additional copies of this product please adjust the quantity in the cart. For more than 20 copies, please contact our Customer Support team on +44 (0)203 327 3140.
You have already added this product in the cart. If you would like to add additional copies of this product please adjust the quantity in the cart.
For more than 20 copies, please contact our Customer Support team on +44 (0)203 327 3140.
You have selected more than three (3) trainings. Please contact our Customer Service team.Please contact our Customer Service team on Email: sales@saiglobal.com Phone: 131 242 (Within Australia)
You have already added a product with different Currency. Please change the currency.
This product cannot be added to your cart right now. Please contact our Customer Service team on Email: standards@saiglobal.comPhone: +44 0203 327 3140
You have already saved 6 Quotes. Please contact our Customer Service Team.