Electric cables - Aerial bundled - Polymeric insulated - Voltages 6.35/11 (12) kV and 12.7/22 (24) kV Metallic screened (Reconfirmed 2021)
Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

11-09-2003

Preview

Specifies the construction, dimensions, and test requirements for steel wire supported, three-core aerial bundled cable, having individually screened phase cables insulated with cross-linked polyethylene, sheathed with high density polyethylene.

Committee
EL-003
DocumentType
Standard
ISBN
0 7337 5487 2
Pages
19
ProductNote
Pending Revision indicates that as a result of the Aged Standards review process, the document needs updating. If no project proposal, meeting the quality criteria, is received within the 12 month timeframe, the document shall be withdrawn.
PublisherName
Standards Australia
Status
Current
Supersedes

First published as AS 3599.1-1988.Jointly revised and designated AS/NZS 3599.1:2003. Originated as AS 3599.1-1988. Jointly revised and designated AS/NZS 3599.1:2003.

AS/NZS 2857:1996 Timber drums for insulated electric cables and bare conductors
AS/NZS 1429.1:2006 Electric cables - Polymeric insulated For working voltages 1.9/3.3 (3.6) kV up to and including 19/33 (36) kV
AS/NZS 1660.3:1998 Test methods for electric cables, cords and conductors Electrical tests (Reconfirmed 2017)
AS/NZS 1429.1:2000 Electric cables - Polymeric insulated - For working voltages 1.9/3.3 (3.6) kV up to and including 19/33 (36) kV
AS/NZS 3008.1.2:1998 Electrical installations - Selection of cables - Cables for alternating voltages up to and including 0.6/1 kV - Typical New Zealand installation conditions
AS/NZS 3008.1.1:1998 Electrical installations - Selection of cables - Cables for alternating voltages up to and including 0.6/1 kV - Typical Australian installation conditions
AS/NZS 1125:2001 Conductors in insulated electric cables and flexible cords (Reconfirmed 2017)
AS/NZS 3808:2000 Insulating and sheathing materials for electric cables
AS/NZS 1660.2.2:1998 Test methods for electric cables, cords and conductors Insulation, extruded semi-conductive screens and non-metallic sheaths - Methods specific to elastomeric, XLPE and XLPVC materials (Reconfirmed 2017)
AS 3983-1991 Metal drums for insulated electric cables and bare conductors (Reconfirmed 2016)
AS 1222.1-1992 Steel conductors and stays - Bare overhead Galvanized (SC/GZ) (Reconfirmed 2016)
AS 1222.2-1992 Steel conductors and stays - Bare overhead Aluminium clad (SC/AC) (Reconfirmed 2016)
AS/NZS 1660.2.1:1998 Test methods for electric cables, cords and conductors Insulation, extruded semi-conductive screens and non-metallic sheaths - Methods for general application (Reconfirmed 2017)

AS/NZS 7000:2016 Overhead line design
HB 331-2012 Overhead line design
AS/NZS 7000:2010 Overhead line design - Detailed procedures

View more information
£50.86
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.