1 - AS/NZS 4213.1:1994 RADIOTHERAPY SIMULATORS - FUNCTIONAL PERFORMANCE CHARACTERISTICS
4 - PREFACE
5 - CONTENTS
6 - 1 Scope and object
6 - 1.1 Scope
7 - 1.2 Object
7 - 1.3 Environmental conditions
7 - 1.3.1 General
7 - 1.3.2 Transport and storage
7 - 2 Normative references
8 - 3 Terminology and definitions
8 - 3.1 Terminology
8 - 3.2 Definitions
8 - 4 Standardized test conditions
8 - 4.1 Angle and-linear settings
9 - 4.2 Positioning of the measuring plane and RADIATION DETECTORS
9 - 4.3 FOCAL SPOT and LOADING FACTORS
9 - 5 IndicatIon of DELINEATED RADIATION FI ELDS
9 - 5.1 Numerical field-indicator
9 - 5.1.1 Information to the USER
9 - 5.1.2 Test
10 - 5.2 LIGHT FIELD-INDICATOR
11 - 5.2.1 Information to the USER
11 - 5.2.2 Test
11 - 5.3 Reproducibility
11 - 5.3.1 Information to the USER
11 - 5.3.2 Test
12 - 5.4 Geometry of the DELINEATOR
12 - 5.4.1 Information to the USER
12 - 5.4.2 Test
13 - 5.5 Illuminance of the DELINEATED LIGHT FIELD
13 - 5.5.1 Information to the USER
13 - 5.5.2 Test
13 - 6 Indication of DELINEATED RADIATION BEAM AXIS
13 - 6.1 Indication of the DELINEATED RADIATION BEAM AXIS on ENTRANCE SURFACE
13 - 6.1.1 Information to the USER
14 - 6.1.2 Test
15 - 6.2 Indication of the DELINEATED RADIATION BEAM AXIS on exit surface
15 - 6.2.1 Information to the USER
15 - 6.2.2 Test
15 - 6.3 Variationof the DELINEATED RADIATION BEAM AXIS with source axis distances (SAD)
15 - 6.3.1 Information to the USER
16 - 6.3.2 Tests
16 - 7 ISOCENTRE
16 - 7.1 Displacement of the DELINEATED RADIATI ON BEAM AXIS from the ISOCENTRE
16 - 7.1.1 Information to the USER
16 - 7.1.2 Test
19 - 7.2 Indication of the ISOCENTRE
19 - 7.2.1 Information to the USER
19 - 7.2.2 Test
19 - 7.3 Displacement of the DELINEATED RADIATION BEAM AXIS with change in FOCAL SPOT
19 - 7.3.1 Information to the USER
19 - 7.3.2 Test
19 - 8 Indication of the distance along the DELINEATED RADIATION BEAM AXIS
19 - 8.1 Device for indicating distance from ISOCENTRE
19 - 8.1.1 Information to the USER
20 - 8.1.2 Test
20 - 8.2 Device for indicating distance from RADIATION SOURCE
20 - 8.2.1 Information to the USER
20 - 8.2.2 Test
20 - 8.3 Indication of IMAGE RECEPTOR PLANE to ISOCENTRE distance
20 - 8.3.1 Information to the USER
20 - 8.3.2 Test
21 - 8.4 Numerical indication of the RADIATI ON SOURCE to ISOCENTRE distance
21 - 8.4.1 Information to the USER
21 - 8.4.2 Test
21 - 9 Zero position of rotational scales
21 - 9.1 Information to the USER
21 - 9.2 Tests
21 - 9.2.1 GANTRY rotation, Axis (1)
22 - 9.2.2 Roll of the RADIATION HEAD, Axis (2)
22 - 9.2.3 Pitch of the RADIATION HEAD, Axis (3)
22 - 9.2.4 Rot ati on of the DELINEATOR, Axis (4)
22 - 9.2.5 Test for ISOCENTRIC rotation of the PATIENT SUPPORT, Axis (5), and rotation of the table top, Axis (6)
23 - 9.2.6 Test for pitch and roll of the table top, Axes (7) and (8)
23 - 10 Congruence of opposed DELINEATED RADIATION FIELDS
23 - 10.1 Information to the USER
23 - 10.2 Test
23 - 11 Movements of the PATIENT SUPPORT
23 - 11.1 Vertical movement of the table top
23 - 11.1.1 Information to the USER
24 - 11.1.2 Test
24 - 11.2 ISOCENTRIC rotation of the PATIENT SUPPORT
24 - 11.2.1 Information to the USER
25 - 11.2.2 Test
25 - 11.3 Parallelism of PATIENT SUPPORT rotational axes
25 - 11.3.1 Information to the USER
25 - 11.3.2 Test
26 - 11.4 Rigidity of the PATIENT SUPPORT
26 - 11.4.1 Longitudinal rigidity of the PATIENT SUPPORT
27 - 11.4.2 Lateral rigidity of the PATIENT SUPPORT
29 - Annex A - Format for presentation of functional performance values