• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

AS/NZS 4284:2008

Current
Current

The latest, up-to-date edition.

Testing of building facades
Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

28-04-2008

Preview

1 - AS/NZS 4284:2008 TESTING OF BUILDING FACADES
4 - PREFACE
6 - CONTENTS
7 - 1 SCOPE
7 - 2 REFERENCED DOCUMENTS
7 - 3 DEFINITIONS
7 - 3.1 BMU
7 - 3.2 Framing members
7 - 3.3 Specifier
7 - 3.4 Test facility
8 - 3.5 Uncontrolled water
8 - 4 NOTATION
8 - 5 PRINCIPLE
8 - 6 APPARATUS
9 - 7 SAMPLE PREPARATION
9 - 7.1 Test sample
9 - 7.2 Drawings
10 - 8 PROCEDURE
10 - 8.1 Test sequence
10 - 8.1.1 General
10 - 8.1.2 Variation of test sequence or retesting
10 - 8.2 Preliminary tests
10 - 8.2.1 General
10 - 8.2.2 Static pressure
10 - 8.2.3 Water
10 - 8.3 Structural test at serviceability limit state
10 - 8.3.1 Structural-test pressures
11 - 8.3.2 Location of the displacement transducers
11 - 8.3.3 Pressure loading sequence
12 - 8.3.4 Displacement measurement of spandrel panels
13 - 8.3.5 Calculation of deflection/span ratio
13 - 8.3.6 Calculation of successive member displacement
13 - 8.3.7 Calculation of maximum displacement
13 - 8.4 Air infiltration test
13 - 8.4.1 Test pressure
14 - 8.4.2 Procedure
14 - 8.5 Water penetration test by static pressure
14 - 8.5.1 Test pressure
14 - 8.5.2 Procedure
14 - 8.6 Water penetration test by cyclic pressure
14 - 8.6.1 Test pressure
15 - 8.6.2 Procedure
15 - 8.7 BMU restraint test
15 - 8.7.1 Test load
15 - 8.7.2 Procedure
15 - 8.8 Structural test at ultimate limit state
15 - 8.8.1 Test pressures
16 - 8.8.2 Procedure
16 - 8.8.3 Spandrel panel
16 - 8.9 Seismic test
16 - 8.9.1 Test displacement
16 - 8.9.2 Procedure
16 - 8.10 Seal degradation test
17 - 9 PERFORMANCE REQUIREMENTS
17 - 9.1 General
17 - 9.2 Structural test at serviceability limit state
17 - 9.2.1 Deflection/span ratios
17 - 9.2.2 Successive member displacement
17 - 9.2.3 Maximum displacement
17 - 9.3 Air infiltration test
17 - 9.4 Water penetration test
17 - 9.5 Seismic test at serviceability limit state displacement
17 - 9.6 BMU restraint test
18 - 9.7 Structural test at ultimate limit state
18 - 9.8 Seismic test at ultimate limit state displacement
18 - 9.9 Seal degradation test
18 - 10 TEST REPORT
18 - 10.1 Preliminary test report
18 - 10.2 Official test report
20 - APPENDIX A - INFORMATION TO BE SUPPLIED BY SPECIFIER
23 - APPENDIX B - SAMPLE PREPARATION
23 - B1 INTRODUCTION
23 - B2 TEST SAMPLE
25 - B3 REQUIREMENTS
26 - B4 INCLINED GLAZING
27 - APPENDIX C - STRENGTH TEST AT ULTIMATE LIMIT STATE LOADING
32 - APPENDIX D - AIR INFILTRATION TESTING
34 - APPENDIX E - WATER PENETRATION TESTING
36 - APPENDIX F - SEISMIC TESTING

Sets out methods of testing building facades for environmental loading including water penetration and air infiltration as well as structural tests. Optional tests include seismic testing, seal degradation and building maintenance unit (BMU) restraint.

This Standard sets out a method for determining the performance of a representative building facade under simulated conditions of loading. This Standard may be applied to all types of facades including low- and high-rise, commercial, industrial and residential buildings. Tests include displacement of the facade or prototype, water penetration and structural integrity at ultimate limit state as well as optional tests, including BMU restraint, seismic loading and seal degradation. This test method is applicable to prototype testing in a test facility and on-site testing.

Committee
BD-080
DocumentType
Standard
ISBN
0 7337 8619 7
Pages
31
PublisherName
Standards Australia
Status
Current
Supersedes

First published as Joint Standard AS/NZS 4284:1995.Second edition 2008. First published as AS/NZS4284:1995. Second edition 2008.

AS 1170.4-2007 Structural design actions Earthquake actions in Australia (Reconfirmed 2018)
AS/NZS 1170.1:2002 Structural design actions Permanent, imposed and other actions
AS/NZS 1170.0:2002 Structural design actions General principles
AS 4211.3-1996 Gas recovery or combined recovery and recycling equipment Fluorocarbon refrigerants from commercial/domestic refrigeration and airconditioning systems
AS 1170.4 SUPP 1-1993 Minimum design loads on structures (known as the SAA Loading Code) Earthquake loads - Commentary (Supplement to AS 1170.4-1993)
AS/NZS 1170.2:2002 Structural design actions Wind actions
AS 4211.1-1996 Gas recovery or combined recovery and recycling equipment Fluorocarbon refrigerants from automotive airconditioning systems

AS 2047-2014 Windows and external glazed doors in buildings

View more information
£68.93
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.