• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

AS/NZS 4783.2:2002

Current
Current

The latest, up-to-date edition.

Performance of electrical lighting equipment - Ballasts for fluorescent lamps Energy labelling and minimum energy performance standards requirements (Reconfirmed 2013)
Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

23-12-2002

Preview

1 - AS/NZS 4783.2:2002 PERFORMANCE OF ELECTRICAL LIGHTING EQUIPMENT- BALLASTS FOR FLUORESCENT LAMPS - ENERGY LABELLING AND...
4 - PREFACE
5 - CONTENTS
6 - FOREWORD
7 - 1 SCOPE
7 - 2 APPLICATION
7 - 3 REFERENCED DOCUMENTS
8 - 4 DEFINITIONS
8 - 4.1 Energy efficiency index (EEI) classification
8 - 4.2 Minimum energy performance standards (MEPS)
8 - 4.3 Supplier
8 - 4.4 Total input power
8 - 4.5 Corrected total input power
8 - 5 ENERGY EFFICIENCY INDEX (EEI) CLASSIFICATION AND LABELLING
8 - 5.1 Determination of corrected total input power (Ptot.cor.)
8 - 5.1.1 Number of samples
9 - 5.1.2 Determination of ballast efficiency
10 - 5.2 Determination of average corrected total input power
10 - 5.3 Determination of EEI classification
10 - 5.3.1 Classification tables
10 - 5.3.2 Additional requirements for A1 classification
10 - 5.4 Labelling of EEI
10 - 5.4.1 Australia
10 - 5.4.2 New Zealand
10 - 6 PERFORMANCE REQUIREMENTS
10 - 6.1 General
11 - 6.2 Performance prerequisites
11 - 6.3 BLF declaration
11 - 6.4 Minimum energy performance standards (MEPS)
11 - 6.4.1 Australia
11 - 6.4.2 New Zealand
11 - 7 APPLICATION AND TEST RESULT FORMATS
11 - 7.1 Application for registration for MEPS in Australia
11 - 7.1.1 Registration
12 - 7.1.2 Report format
12 - 7.2 Holding of records in Australia
12 - 7.2.1 General
12 - 7.2.2 Test report
12 - 7.2.3 Availability
12 - 7.3 Holding of records in New Zealand
12 - 7.3.1 General
12 - 7.3.2 Test report
12 - 7.3.3 Availability
15 - APPENDIX A - NOTIFICATION OF ENERGY PERFORMANCE CHARACTERISTICS

Specifies classification, labelling and minimum energy performance requirements for ballasts for linear fluorescent lamps for use on 230V to 250 volt a.c. at 50Hz supply. This Standard is to be read in conjunction with AS/NZS4783.1.

This Standard specifies requirements for the classification of ballasts for a range of fluorescent lamp types (refer to Tables 1 to 3) according to their Energy Efficiency Index (EEI) and the form of labelling of the EEI, which is generally shown on the ballast rating plate. This Standard also specifies the minimum energy performance standards (MEPS) requirements for certain fluorescent lamp ballasts. The ballasts covered by this Standard are the ferromagnetic or electronic type, that are used with fluorescent lamps with a rated lamp power from 10 W to 70 W, for use on 50 Hz supplies of 230/240/250 V or a range which includes one or more of these voltages. This Standard covers ballasts that are supplied as separate components or as part of a luminaire. This Standard does not cover the following ballast-lamp combinations: (a) Primarily for use on d.c. supply or batteries. (b) Primarily for the production of light outside the visible spectrum, ie. 400 nm to 800 nm. (c) For exit signs within the scope of AS/NZS 2293. (d) Hazardous area lighting equipment, within the scope of AS/NZS 2380, AS/NZS 60079 and AS/NZS 61241 Series of Standards.

Committee
EL-041
DocumentType
Standard
ISBN
0 7337 4960 7
Pages
13
ProductNote
PublisherName
Standards Australia
Status
Current
Supersedes

First published as AS/NZS 4783.2:2002.Reconfirmed 2013. First published as AS/NZS 4783.2:2002.

AS 2380.1-1989 Electrical equipment for explosive atmospheres - Explosion-protection techniques General requirements (Reconfirmed 2013)
AS/NZS 60079.2:2002 Electrical apparatus for explosive gas atmospheres Pressurized enclosures 'p'
AS 2380.4-1994 Electrical equipment for explosive atmospheres - Explosion-protection techniques Pressurized rooms or pressurized enclosures (Reconfirmed 2013)
AS/NZS 60079.1:2002 Electrical apparatus for explosive gas atmospheres Flameproof enclosures 'd'
AS/NZS 4783.1:2001 Performance of electrical lighting equipment - Ballasts for fluorescent lamps Method of measurement to determine energy consumption and performance of ballast-lamp circuits (Reconfirmed 2013)
AS 2380.6-1988 Electrical equipment for explosive atmospheres - Explosion-protection techniques Increased safety
AS/NZS 61241.1.1:1999 Electrical apparatus for use in the presence of combustible dust Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus
AS/NZS 60079.12:2000 Electrical apparatus for explosive gas atmospheres Classification of mixtures of gases or vapours with air according to their maximum experimental safe gaps and minimum igniting currents
AS/NZS 60079.11:2000 Electrical apparatus for explosive gas atmospheres Intrinsic safety 'i'
AS 2380.9-1991 Electrical equipment for explosive atmospheres - Explosion-protection techniques Type of protection n - Non-sparking
AS/NZS 61241.3:1999 Electrical apparatus for use in the presence of combustible dust Classification of areas where combustible dusts are or may be present
AS/NZS 60079.1.1:2002 Electrical apparatus for explosive gas atmospheres Flameproof enclosures 'd' - Method of test for ascertainment of maximum experimental safe gap
AS/NZS 61241.2.3:2000 Electrical apparatus for use in the presence of combustible dust Test methods - Method for determining the minimum ignition energy of dust/air mixtures
AS/NZS 60079.6:2000 Electrical apparatus for explosive gas atmospheres Oil-immersion 'o'
AS/NZS 61241.4:2002 Electrical apparatus for use in the presence of combustible dust Type of protection 'pD'
AS/NZS 60079.20:2000 Electrical apparatus for explosive gas atmospheres Data for flammable gases and vapours, relating to the use of electrical apparatus
AS/NZS 61241.1.2:2000 Electrical apparatus for use in the presence of combustible dust Electrical apparatus protected by enclosures and surface temperature limitation - Selection, installation and maintenance
AS/NZS 2293.1:1998 Emergency evacuation lighting for buildings System design, installation and operation
AS/NZS 60079.5:2000 Electrical apparatus for explosive gas atmospheres Powder filling 'q'
AS/NZS 60921:2002 Ballasts for tubular fluorescent lamps - Performance requirements (Reconfirmed 2019)
AS/NZS 2293.2:1995 Emergency escape lighting and exit signs for buildings Inspection and maintenance
AS/NZS 2293.3:1995 Emergency evacuation lighting for buildings Emergency luminaires and exit signs
AS/NZS 60079.7:2002 Electrical apparatus for explosive gas atmospheres Increased safety 'e'
AS/NZS 60929:2000 Auxiliaries for lamps - A.C. supplied electronic ballasts for tubular fluorescent lamps - Performance requirements
AS/NZS 60079.4:2000 Electrical apparatus for explosive gas atmospheres Method of test for ignition temperature
AS/NZS 61231:2001 International lamp coding system (ILCOS) (Reconfirmed 2013)
AS 2380.2-1991 Electrical equipment for explosive atmospheres - Explosion-protection techniques Flameproof enclosure d
AS 2380.7-1987 Electrical equipment for explosive atmospheres - Explosion-protection techniques - Intrinsic safety i
AS/NZS 61241.2.1:2000 Electrical apparatus for use in the presence of combustible dust Test methods - Methods for determining the minimum ignition temperature of dust
AS/NZS 60079.0:2000 Electrical apparatus for explosive gas atmospheres General requirements
AS/NZS 61241.2.2:2000 Electrical apparatus for use in the presence of combustible dust Test methods - Method for determining the electrical resistivity of dust in layers

AS/NZS 1158.6:2010 Lighting for roads and public spaces Luminaires

View more information
£50.86
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.