    Electric cables - Polymeric insulated For working voltages up to and including 0.6/1 kV

    Available format(s):  Hardcopy, PDF 1 User, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Superseded date:  30-06-2017

    Language(s): 

    Published date:  05-12-1999

    Publisher:  Standards Australia

    Add to Watchlist

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 - AS/NZS 5000.1:1999 ELECTRIC CABLES-POLYMERIC INSULATED - FOR WORKING VOLTAGES UP TO AND INCLUDING 0.6/1 kV
    4 - PREFACE
    5 - CONTENTS
    6 - 1 SCOPE
    6 - 2 REFERENCED DOCUMENTS
    6 - 3 DEFINITIONS
    6 - 3.1 Aerial cables
    6 - 3.2 Core (of a cable)
    7 - 3.3 Direction of lay
    7 - 3.4 Fictitious values
    7 - 3.5 Fixed cable
    7 - 3.6 Flexible cable
    7 - 3.7 Multi-core cable
    7 - 3.8 Pitch circle diameter
    7 - 3.9 Routine tests
    7 - 3.10 Sample tests
    7 - 3.11 Shall
    7 - 3.12 Should
    7 - 3.13 Type tests
    8 - 3.14 Voltage designation
    8 - 3.15 Wavelength or length of lay
    8 - 4 VOLTAGE DESIGNATION
    8 - 5 CONDUCTORS
    8 - 6 INSULATION
    8 - 6.1 Materials
    8 - 6.1.1 General
    9 - 6.1.2 Aerial cables or fixed cables used in aerial applications
    9 - 6.2 Application
    9 - 6.3 Thickness
    10 - 6.4 Core identification
    10 - 6.4.1 Restricted colours
    10 - 6.4.2 Method
    11 - 6.4.3 Colours
    11 - 6.4.4 Figures and words
    11 - 7 CONSTRUCTION OF CABLES
    11 - 7.1 Flat cables
    11 - 7.2 Circular cables
    11 - 7.2.1 Lay-up of cores
    11 - 7.2.2 Fillers, barrier tapes and binders
    12 - 8 BEDDING
    12 - 8.1 General
    12 - 8.2 Bedding under a metallic layer other than armour
    12 - 8.3 Material
    12 - 8.4 Application
    12 - 8.4.1 Taped bedding
    12 - 8.4.2 Extruded bedding
    12 - 8.4.3 Thickness
    13 - 8.5 Bedding under armour
    13 - 8.5.1 Material
    13 - 8.5.2 Application
    13 - 8.5.3 Thickness
    13 - 9 METALLIC LAYERS
    13 - 10 SEPARATION LAYER
    13 - 10.1 General
    13 - 10.2 Material and application
    13 - 10.3 Thickness
    14 - 10.4 Tests
    14 - 11 ARMOUR
    14 - 11.1 Material
    14 - 11.2 Dimensions of wire and tape
    14 - 11.3 Application
    14 - 11.3.1 General
    14 - 11.3.2 Wire armour
    15 - 11.3.3 Tape armour
    15 - 11.4 Further protection
    15 - 12 METALLIC SHEATH
    15 - 12.1 Material
    15 - 12.2 Application
    15 - 12.3 Thickness
    15 - 12.4 Further protection
    16 - 13 NON-METALLIC SHEATH
    16 - 13.1 Material
    16 - 13.1.1 General
    16 - 13.1.2 Not applicable
    16 - 13.2 Application
    16 - 13.3 Thickness
    16 - 13.3.1 Average thickness
    17 - 13.3.2 Minimum thickness
    17 - 14 FURTHER PROTECTION
    17 - 14.1 Polyamide jacket
    18 - 14.2 Other optional protection
    18 - 15 UNPROTECTED MULTI-CORE CABLES
    18 - 15.1 Unprotected multi-core flat cables
    18 - 15.2 Unprotected multi-core laid-up cores
    18 - 16 MARKING
    18 - 16.1 Information to be marked
    18 - 16.2 Means of marking
    19 - 16.3 Marking of packaging
    19 - 17 TESTS
    23 - APPENDIX A - PURCHASING GUIDELINES
    23 - A1 GENERAL
    23 - A2 INFORMATION TO BE SUPPLIED BY THE PURCHASER
    24 - APPENDIX B - THE FICTITIOUS CALCULATION METHOD FOR THE DETERMINATION OF THE DIMENSIONS OF PROTECTIVE COVERINGS
    24 - B1 INTRODUCTION
    24 - B2 GENERAL
    24 - B3 METHOD
    24 - B3.1 Conductors
    25 - B3.2 Cores
    25 - B3.3 Diameter over laid-up cores
    26 - B3.4 Bedding
    27 - B3.5 Metallic screen or concentric conductor
    28 - B3.6 Metallic sheath
    28 - B3.7 Separation layer
    28 - B3.8 Armour
    29 - B3.9 Non-metallic sheath

    Abstract - (Show below) - (Hide below)

    Specifies the construction, dimension and test requirements for cables insulated with polymeric materials intended for use in electrical installations at working voltages up to and including 0.6/1 kV. It does not apply to specialized polymeric insulated cables for which there are separate Australian/New Zealand Standards, e.g. flexible lift control cables, neutral screened cables, welding cables, ships cables, flexible cords, single and flat multi-core non-metallic sheathed building cables and aerial bundled cables.

    General Product Information - (Show below) - (Hide below)

    Committee EL-003
    Document Type Standard
    Publisher Standards Australia
    Status Superseded
    Superseded By
    Supersedes
    Under Revision

    History - (Show below) - (Hide below)

    Amendment 1 See DR 00138 CP. Under Revision see DR 02437 First published in Australia in part as part of AS C50-1928.Second edition 1939 (being endorsement of BS 7-1939 with amendments).AS C116 first published 1941.AS C130 first published 1941.AS (E)C502 first published 1943.AS C50-1939, AS C116-1941, AS C130-1941 and AS (E)C502-1943 revised, amalgamated and designated AS C116-1950.AS C147 first published 1950.Third edition AS C116-1955.Second edition AS C147-1955.Fourth edition AS C116-1967.Third edition AS C147-1967.Fourth edition 1969.Fourth edition AS C116-1970.AS C189 first published 1971.Fifth edition AS C147-1972.Sixth edition AS C116-1972.Revised and redesignated in part as AS 3116-1974.AS C189-1971 and part of AS C147-1972 revised, amalgamated and redesignated AS 3147-1974.AS C189-1971 withdrawn 1976.AS C147-1972 withdrawn 1976.Second edition AS 3147-1976.Second edition AS 3116-1976.AS 3198 first published 1977.Third edition AS 3116-1981.Third edition AS 3147-1981.Fourth edition 1988.Fourth edition AS 3116-1990.Second edition AS 3198-1990.Fifth edition AS 3147-1992.First published in New Zealand as NZS/AS 3198-1990.NZS/AS 3116 first published 1990.NZS/AS 3198-1990 jointly revised and designated as AS/NZS 3198:1996.NZS/AS 3116-1990 jointly revised and designated as AS/NZS 3116:1996.AS 3147-1992, AS/NZS 3116:1996 and AS/NZS 3198:1996 jointly revised, amalgamated and redesignated AS/NZS 5000.1:1999. First published in Australia in part as part of AS C50-1928. Second edition 1939 (being endorsement of BS 7-1939 with amendments). AS C116 first published 1941. AS C130 first published 1941. AS (E)C502 first published 1943. AS C50-1939, AS C116-1941, AS C130-1941 and AS (E)C502-1943 revised, amalgamated and designated AS C116-1950. AS C147 first published 1950. Third edition AS C116-1955. Second edition AS C147-1955. Fourth edition AS C116-1967. Third edition AS C147-1967. Fourth edition 1969. Fourth edition AS C116-1970. AS C189 first published 1971. Fifth edition AS C147-1972. Sixth edition AS C116-1972. Revised and redesignated in part as AS 3116-1974. AS C189-1971 and part of AS C147-1972 revised, amalgamated and redesignated AS 3147-1974. AS C189-1971 withdrawn 1976. AS C147-1972 withdrawn 1976. Second edition AS 3147-1976. Second edition AS 3116-1976. AS 3198 first published 1977. Third edition AS 3116-1981. Third edition AS 3147-1981. Fourth edition 1988. Fourth edition AS 3116-1990. Second edition AS 3198-1990. Fifth edition AS 3147-1992. First published in New Zealand as NZS/AS 3198-1990. NZS/AS 3116 first published 1990. NZS/AS 3198-1990 jointly revised and designated as AS/NZS 3198:1996. NZS/AS 3116-1990 jointly revised and designated as AS/NZS 3116:1996. AS 3147-1992, AS/NZS 3116:1996 and AS/NZS 3198:1996 jointly revised, amalgamated and redesignated AS/NZS 5000.1:1999.

    Standards Referencing This Book - (Show below) - (Hide below)

    AS/NZS 3001:2001 Electrical installations - Relocatable premises (including caravans and tents) and their site installations
    AS/NZS 3018:2001 Electrical installations - Domestic installations
    AS/NZS 5000.3:2003 Electric cables - Polymeric insulated Multicore control cables (Reconfirmed 2017)
    AS/NZS 2373:2003 Electric cables - Twisted pair for control and protection circuits (Reconfirmed 2017)
    AS/NZS 4026:2001 Electric cables - For underground residential distribution systems
    AS/NZS 2802:2000 Electric cables - Reeling and trailing - For mining and general use (other than underground coal mining) (Reconfirmed 2020)
    AS/NZS 3003:2003 Electrical installations - Patient treatment areas of hospitals and medical, dental practices and dialyzing locations
    AS/NZS 1802:2003 Electric cables - Reeling and trailing - For underground coal mining purposes
    AS/NZS 4961:2003 Electric cables - Polymeric insulated - For distribution and service applications (Reconfirmed 2017)
    AS/NZS 1972:2002 Electric cables - Underground coal mines - Other than reeling and trailing
    AS 2832.2-2003 Cathodic protection of metals Compact buried structures
    AS/NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies Type-tested and partially type tested assemblies (IEC 60439-1:1999 MOD)
    AS/NZS 3808:2000 Insulating and sheathing materials for electric cables
    AS/NZS 2144:2002 Traffic signal lanterns
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective