• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

AS/NZS 61048:2002

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Auxiliaries for lamps - Capacitors for use in tubular fluorescent and other discharge lamp circuits - General and safety requirements (IEC 61048:1991, MOD)
Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

20-01-2020

Language(s)

English

Published date

27-08-2002

Preview

1 - AS/NZS 61048:2002 AUXILIARIES FOR LAMPS-CAPACITORS FOR USE IN TUBULAR FLUORESCENT AND OTHER DISCHARGE LAMP CIRCUITS-GENERAL A
4 - PREFACE
5 - CONTENTS
7 - SECTION 1 - GENERAL
7 - 1 Scope
8 - 2 Normative references
8 - 3 Definitions
8 - 3.1 Rated voltage
9 - 3.2 Rated maximum temperature
9 - 3.3 Rated minimum temperature
9 - 3.4 Discharge resistor
9 - 3.5 Tangent of loss angle
9 - 3.6 Self-healing
9 - 3.7 Type test
9 - 3.8 Type test sample
9 - 3.9 Capacitor of type A
9 - 3.10 Capacitor of type B
9 - 4 General requirements
11 - 5 General notes on tests
11 - 6 Marking
13 - SECTION 2 – SAFETY
13 - 7 Terminations
13 - 8 Creepage distances and clearances
14 - 9 Voltage rating
14 - 10 Fuses
15 - 11 Discharge resistors
16 - SECTION 3 – TESTS
16 - 12 Testing sequence
16 - 13 Sealing and heating test
16 - 13.1 Sealing and heating test for type A capacitors
16 - 13.2 Sealing and heating test for type B capacitors
17 - 14 High-voltage test
17 - 14.1 High-voltage test between terminals
17 - 14.2 High-voltage test between terminals and container
17 - 15 Resistance to adverse operating conditions
18 - 15.1 Humidity test with voltage applied
18 - 15.2 Current (discharge) test
19 - 16 Resistance to heat, fire and tracking
21 - 17 Self-healing test
21 - 18 Destruction test
21 - 18.1 Test A
24 - 18.2 Test B
26 - 18.3 Non-self-healing capacitors
28 - Annex A - Test voltage
29 - Annex B - Temperature adjustment of test enclosure
30 - Annex C - Test for conformity of manufacturer
30 - C.1 Sample testing
30 - C.2 Recommendations for 100% conformity of production testing
31 - Annex D - Guide to calculating equipment settings for tests in Clause 15.2 and 18.1.3
31 - D.1 Test according to Clause 15.2 Current Discharge Test Input Data
31 - D.2 Calculation for a given capacitance value (C)
32 - D.3 Test according to Clause 18.1.3 High r.m.s. current test input data
32 - D.4 Calculation

Specifies the general and safety requirement for capacitors up to 2.5 kVAR having a rated voltage up to 1000 volt intended for discharge lamp circuits operating at 50/60 Hz. This Standard is reproduced from IEC 61048 and varied for Australian/New Zealand conditions.

This International Standard states the requirements for both self-healing and non-self-healing continuously rated a.c. capacitors of up to and including 2,5 kvar, and not less than 0,1 F, having a rated voltage not exceeding 1 000 V, which are intended for use in discharge lamp circuits* operating at 50 Hz or 60 Hz and at altitudes up to 3 000 m.It covers capacitors intended for connection in shunt or in series with the lamp circuit or an effective combination of these.It covers only impregnated or unimpregnated capacitors, having a dielectric of paper, plastic film or a combination of both, either metallized or with metal foil electrodes.This standard does not cover radio-interference suppressor capacitors the requirements for which are found in IEC 60384-14.Tests given in this standard are type tests. Requirements for testing individual capacitors during production are not included.

Committee
EL-041
DocumentType
Standard
ISBN
0 7337 4772 8
Pages
30
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

First published as AS 2644-1983.Second edition 1990.Jointly revised and redesignated in part as AS/NZS 61048:2002. First published as AS 2644-1983. Second edition 1990. Jointly revised and redesignated in part as AS/NZS 61048:2002.

AS/NZS 60598.1:2001 Luminaires General requirements and tests (IEC 60598.1:1996, MOD)
AS/NZS 61049:2002 Auxiliaries for lamps - Capacitors for use in tubular fluorescent and other discharge lamp circuits - Performance requirements (Reconfirmed 2016)
AS/NZS 60695.2.10:2001 Glowing/hot wire based test methods Glow-wire apparatus and common test procedure
AS/NZS 4695.2.2:1996 Fire hazard testing of electrotechnical products Test methods - Needle-flame test

AS/NZS 1158.6:2010 Lighting for roads and public spaces Luminaires
AS/NZS 1680.1:2006 Interior and workplace lighting General principles and recommendations
AS/NZS 61347.2.8:2003 Lamp controlgear Particular requirements for ballasts for fluorescent lamps (IEC 61347-2-8:2000, MOD) (Reconfirmed 2019)
AS/NZS 61049:2002 Auxiliaries for lamps - Capacitors for use in tubular fluorescent and other discharge lamp circuits - Performance requirements (Reconfirmed 2016)
AS/NZS 60079.15:2011 Explosive atmospheres Equipment protection by type of protection 'n'
AS/NZS 1158.6:2004 Lighting for roads and public spaces Luminaires

View more information
£82.16
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.