• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

ASTM C 1018 : 1997

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Standard Test Method for Flexural Toughness and First-Crack Strength of Fiber-Reinforced Concrete (Using Beam With Third-Point Loading) (Withdrawn 2006)

Available format(s)

Hardcopy , PDF

Withdrawn date

15-05-2006

Language(s)

English

Published date

10-12-1997

CONTAINED IN VOL 04.02, 2005 Describes the flexural toughness of fiber-reinforced concrete in areas under the load-deflection curve achieved by testing a simply supported beam under third-point loading.

1.1 This test method evaluates the flexural performance of toughness parameters derived from fiber-reinforced concrete in terms of areas under the load-deflection curve obtained by testing a simply supported beam under third-point loading.

Note 1-Toughness determined in terms of areas under the load-deflection curve is an indication of the energy absorption capability of the particular test specimen, and, consequently, its magnitude depends directly on the geometrical characteristics of the test specimen and the loading system.

1.2 This test method provides for the determination of a number of ratios called toughness indices that identify the pattern of material behavior up to the selected deflection criteria. These indices are determined by dividing the area under the load-deflection curve up to a specified deflection criterion, by the area up to the deflection at which first crack is deemed to have occurred. Residual strength factors that represent the average post-crack load retained over a specific deflection interval as a percentage of the load at first crack are derived from these indices.

Note 2-Index values may be increased by preferential alignment of fibers parallel to the longitudinal axis of the beam caused by fiber contact with the mold surfaces or by external vibration. However, index values appear to be independent of geometrical specimen and testing variables, such as span length, which do not directly affect fiber alignment.

1.3 This test method provides for the determination of the first-crack flexural strength using the load corresponding to the point on the load-deflection curve defined in 3.1.1 as first crack, and the formula for modulus of rupture given in Test Method C78.

1.4 Values of flexural toughness and first-crack flexural strength stated in inch-pound units are to be regarded as the standard. Values of toughness indices and residual strength factors are independent of the system of units used to measure load and deflection.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Committee
C 09
DocumentType
Test Method
Pages
8
PublisherName
American Society for Testing and Materials
Status
Withdrawn

ACI 544.4R : 1988 DESIGN CONSIDERATIONS FOR STEEL FIBER REINFORCED CONCRETE
ASTM C 1140 : 2003 Standard Practice for Preparing and Testing Specimens from Shotcrete Test Panels
ASTM C 1140/C1140M : 2011 : REDLINE Standard Practice for Preparing and Testing Specimens from Shotcrete Test Panels
ACI 309R : 2005 GUIDE FOR CONSOLIDATION OF CONCRETE
ASTM C 1140 : 2003 : REV A Standard Practice for Preparing and Testing Specimens from Shotcrete Test Panels
ASTM F 1007 : 1986 : R2002 Standard Specification for Pipeline Expansion Joints of the Packed Slip Type for Marine Application
ACI 311.4R : 2005 GUIDE FOR CONCRETE INSPECTION
ASTM F 1007 : 1986 : R2014 Standard Specification for Pipeline Expansion Joints of the Packed Slip Type for Marine Application
ACI 544.1R : 1996 REPORT ON FIBER REINFORCED CONCRETE
ASTM F 1007 : 1986 : R1996 : EDT 1 Standard Specification for Pipe-Line Expansion Joints of the Packed Slip Type for Marine Application
ASTM F 1007 : 1986 : R2007 Standard Specification for Pipeline Expansion Joints of the Packed Slip Type for Marine Application

ASTM C 823 : 2000 Standard Practice for Examination and Sampling of Hardened Concrete in Constructions
ASTM C 670 : 2015 : REDLINE Standard Practice for Preparing Precision and Bias Statements for Test Methods for Construction Materials

View more information
£62.61
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.