• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

ASTM C 1175 : 1999 : REV A

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Standard Guide to Test Methods and Standards for Nondestructive Testing of Advanced Ceramics
Available format(s)

Hardcopy , PDF

Superseded date

11-11-2014

Language(s)

English

Published date

10-05-1999

CONTAINED IN VOL. 15.01, 2017 Specifies standard procedures and methods for nondestructive testing of advanced ceramics using radiology, ultrasonics, liquid penetrants, and acoustic emission.

1.1 This guide identifies and describes standard procedures and methods for nondestructive testing of advanced ceramics using radiology, ultrasonics, and liquid penetrants.

1.2 This guide is to identify existing standards for nondestructive testing that have been determined to be (or have been modified to be) applicable to the examination of advanced ceramics. These standards have been generated by, and are under the jurisdiction of, ASTM Committee E-7 on Nondestructive Testing. Selection and application of these standards to be followed must be governed by experience and the specific requirements in each individual case, together with agreement between producer and user.

1.3 The values stated in SI units are to be regarded as the standard. The inch-pound units given in parentheses are for information only.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Committee
C 28
DocumentType
Guide
Pages
14
ProductNote
Reconfirmed EV A
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy

ASTM E 1254 : 2013 Standard Guide for Storage of Radiographs and Unexposed Industrial Radiographic Films
ASTM E 1411 : 2016 : REDLINE Standard Practice for Qualification of Radioscopic Systems
ASTM E 1000 : 2016 : REDLINE Standard Guide for Radioscopy
ASTM E 1219 : 2016 : REDLINE Standard Practice for Fluorescent Liquid Penetrant Testing Using the Solvent-Removable Process
ASTM E 1647 : 2016 : REDLINE Standard Practice for Determining Contrast Sensitivity in Radiology
ASTM E 114 : 2015 : REDLINE Standard Practice for Ultrasonic Pulse-Echo Straight-Beam Contact Testing
ASTM E 750 : 2015 : REDLINE Standard Practice for Characterizing Acoustic Emission Instrumentation
ASTM E 494 : 2015 : REDLINE Standard Practice for Measuring Ultrasonic Velocity in Materials
ASTM E 797 : 2005 Standard Practice for Measuring Thickness by Manual Ultrasonic Pulse-Echo Contact Method
ASTM E 1210 : 2016 : REDLINE Standard Practice for Fluorescent Liquid Penetrant Testing Using the Hydrophilic Post-Emulsification Process
ASTM E 587 : 2015 : REDLINE Standard Practice for Ultrasonic Angle-Beam Contact Testing
ASTM E 1441 : 2011 : REDLINE Standard Guide for Computed Tomography (CT) Imaging
ASTM E 1324 : 2016 : REDLINE Standard Guide for Measuring Some Electronic Characteristics of Ultrasonic Testing Instruments
ASTM E 1255 : 2016 : REDLINE Standard Practice for Radioscopy
ASTM E 1695 : 1995 Standard Test Method for Measurement of Computed Tomography (CT) System Performance
ASTM E 999 : 2015 : REDLINE Standard Guide for Controlling the Quality of Industrial Radiographic Film Processing
ASTM E 1570 : 2011 : REDLINE PRACTICE FOR COMPUTED TOMOGRAPHIC (CT) EXAMINATION
ASTM E 650 : 1997 Standard Guide for Mounting Piezoelectric Acoustic Emission Sensors
ASTM E 1209 : 2010 Standard Practice for Fluorescent Liquid Penetrant Testing Using the Water-Washable Process
ASTM E 1208 : 2016 : REDLINE Standard Practice for Fluorescent Liquid Penetrant Testing Using the Lipophilic Post-Emulsification Process
ASTM E 976 : 2015 : REDLINE Standard Guide for Determining the Reproducibility of Acoustic Emission Sensor Response
ASTM E 1453 : 2014 : REDLINE Standard Guide for Storage of Magnetic Tape Media that Contains Analog or Digital Radioscopic Data
ASTM E 1079 : 2016 : REDLINE Standard Practice for Calibration of Transmission Densitometers
ASTM E 317 : 2016 : REDLINE Standard Practice for Evaluating Performance Characteristics of Ultrasonic Pulse-Echo Testing Instruments and Systems without the Use of Electronic Measurement Instruments
ASTM E 1220 : 2016 : REDLINE Standard Practice for Visible Penetrant Testing Using Solvent-Removable Process

View more information
£69.29
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.