• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

ASTM C 1289 : 2020

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board
Available format(s)

Hardcopy , PDF

Superseded date

01-07-2021

Language(s)

English

Published date

13-10-2020

1.1This specification covers the general requirements for faced thermal insulation boards composed of rigid cellular polyisocyanurate surfaced with other materials. The insulation boards are intended for use at temperatures between −40 and 200°F (−40 and 93°C). This specification does not cover cryogenic applications. Consult the manufacturer for specific recommendations and properties in cryogenic conditions. For specific applications, the actual temperature limits shall be agreed upon by the manufacturer and the purchaser.

1.2This standard is intended to apply to rigid cellular polyurethane-modified polyisocyanurate thermal insulation board products that are commercially acceptable as non-structural panels useful in building construction. The term polyisocyanurate encompasses the term polyurethane. For engineering and design purposes, users should follow specific product information provided by board manufacturers regarding physical properties, system design considerations and installation recommendations.

Note 1:See Appendix X1 for guidance on determining wind pressure resistance of panels when required for wall sheathing applications.

1.3The use of thermal insulation materials covered by this specification is typically regulated by building codes, or other agencies that address fire performance. Where required, the fire performance of the material shall be addressed through standard fire test methods established by the appropriate governing documents.

1.4The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

Note 2:For conversion to metric units other than those contained in this standard, refer to IEEE/ASTM SI 10.

1.5This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.6This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Committee
C 16
DocumentType
Standard
Pages
8
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

ASTM D 1079 : 2020 Standard Terminology Relating to Roofing and Waterproofing
ASTM C 728 : 2017 : REV A Standard Specification for Perlite Thermal Insulation Board
ASTM D 7793 : 2020 Standard Specification for Insulated Vinyl Siding
ASTM C 1696 : 2020 Standard Guide for Industrial Thermal Insulation Systems
ASTM C 1558 : 2019 Standard Guide for Development of Standard Data Records for Computerization of Thermal Transmission Test Data for Thermal Insulation
ASTM E 2568 : 2017 : REV A Standard Specification for PB Exterior Insulation and Finish Systems
ASTM C 1535 : 2005 : R2017 Standard Practice for Application of Exterior Insulation and Finish Systems Class PI
ASTM C 1303/C1303M : 2019 Standard Test Method for Predicting Long-Term Thermal Resistance of Closed-Cell Foam Insulation

ASTM C 303 : 2021 Standard Test Method for Dimensions and Density of Preformed Block and Board–Type Thermal Insulation
ASTM C 303 : 2010 : R2016 : EDT 1 Standard Test Method for Dimensions and Density of Preformed Block and Board–Type Thermal Insulation
ASTM E 84 : 2021 Standard Test Method for Surface Burning Characteristics of Building Materials
ASTM C 518 : 2002 Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus
ASTM E 84 : 2020 Standard Test Method for Surface Burning Characteristics of Building Materials
ASTM E 84 : 2021 : REV A Standard Test Method for Surface Burning Characteristics of Building Materials
ASTM C 303 : 1998 Standard Test Method for Dimensions and Density of Preformed Block and Broad-Type Thermal Insulation
ASTM C 518 : 1998 Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus

View more information
£62.61
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.