• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

ASTM C 1478M : 2008

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Standard Specification for Storm Drain Resilient Connectors Between Reinforced Concrete Storm Sewer Structures, Pipes, and Laterals (Metric)
Available format(s)

Hardcopy , PDF

Superseded date

11-11-2014

Language(s)

English

Published date

01-03-2008

CONTAINED IN VOL. 04.05, 2015 Defines the minimum performance and material requirements for resilient connectors used for connections between precast reinforced concrete storm sewer structures conforming to Specification C 478 and pipes, and between precast reinforced concrete pipe and laterals for storm drainage systems.

1.1 This specification covers the minimum performance and material requirements for resilient connectors used for connections between precast reinforced concrete storm sewer structures conforming to Specification C 478 and pipes, and between precast reinforced concrete pipe and laterals for storm drainage systems.

1.1.1 These connectors are designed to prevent soil migration between the pipe and storm sewer structure, and between the pipe and lateral.

1.2 The values stated in SI units are to be regarded as standard. The values given in parentheses are for information only. This specification is the Metric counterpart of Specification C 1478.

Note 1—This specification covers the design, material, and performance of the resilient connection only. Connections covered by this specification are adequate for hydrostatic pressures up to 41 kPa (4.3 m) without leakage when tested in accordance with Section 7. Infiltration quantities for an installed system are dependent upon many factors other than the connections between storm sewer structures and pipe, and allowable quantities must be covered by other specifications and suitable testing of the installed pipeline and system.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use. For a specific warning statement, see 7.2.4.

Committee
C 13
DocumentType
Standard
Pages
3
ProductNote
Reconfirmed 2008
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

ASTM C 1821/C1821M : 2016 Standard Practice for Installation of Underground Circular Precast Concrete Manhole Structures

ASTM D 1149 : 2016-02 TEST METHODS FOR RUBBER DETERIORATION - CRACKING IN AN OZONE CONTROLLED ENVIRONMENT
ASTM A 666 : 2015 : REDLINE Standard Specification for Annealed or Cold-Worked Austenitic Stainless Steel Sheet, Strip, Plate, and Flat Bar
ASTM D 543 : 2014 : REDLINE Standard Practices for Evaluating the Resistance of Plastics to Chemical Reagents
ASTM C 913 : 2016-07 SPECIFICATION FOR PRECAST CONCRETE WATER AND WASTEWATER STRUCTURES
ASTM A 493 : 2016 : REDLINE Standard Specification for Stainless Steel Wire and Wire Rods for Cold Heading and Cold Forging
ASTM D 1566 : 2015 : REDLINE TERMINOLOGY RELATING TO RUBBER
ASTM D 471 : 2016-02 TEST METHOD FOR RUBBER PROPERTY - EFFECT OF LIQUIDS

View more information
£55.10
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.