ASTM D 5464 : 1993 : R2001

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Standard Test Methods for pH Measurement of Water of Low Conductivity
Available format(s)

Hardcopy , PDF

Superseded date

11-11-2014

Language(s)

English

Published date

01-01-2001

1.1 These test methods are applicable to determine the pH of water samples with a conductivity lower than 100 µ S/cm (see Annex A1 and Table A1.1 and Table A1.2 ) over the pH range of 3 to 11 (see Fig. 1). pH measurements of water of low conductivity are problematical (see Annex A2). Specifically, these test methods avoid contamination of the sample with atmospheric gases (see Section 7) and prevent volatile components of the sample from escaping. These test methods provide for pH electrodes and apparatus that address the considerations discussed in Annex A2. These test methods also minimize problems associated with the sample's pH temperature coefficient when the operator uses these test methods to calibrate an on-line pH monitor or controller (see Appendix X1). Two test methods are given as follows:

Test MethodSections
Test Method A-Precise pH Measurement of LowConductivity Water Utilizing the Real-TimeFlowing Sample Procedure5 to 12
Test Method B-pH Measurement of Low Conductivity Water Utilizing the Static Grab SampleProcedure13 to 20

1.2 Test Method A covers the precise measurement of pH in water of low conductivity utilizing a real-time, short duration, flowing sample procedure.

1.3 Test Method B covers the measurement of pH in water of low conductivity with a lower limit of 2.0 S/cm, utilizing a static grab-sample procedure where it is not practicable to take a real-time flowing sample.

Note 1--Test Method A is preferred over Test Method B whenever possible. Test Method A is not subject to the limited conductivity range, temperature interferences, potential KCl contamination, and time limitations found with Test Method B.

1.4 The values stated in SI units are to be regarded as standard.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Committee
D 19
DocumentType
Test Method
Pages
14
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy

ASTM D 1293 : 2018 Standard Test Methods for pH of Water
ASTM D 5128 : 2014 Standard Test Method for On-Line pH Measurement of Water of Low Conductivity
ASTM E 2635 : 2014 Standard Practice for Water Conservation in Buildings Through In-Situ Water Reclamation
ASTM D 6764 : 2002 : R2013 Standard Guide for Collection of Water Temperature, Dissolved-Oxygen Concentrations, Specific Electrical Conductance, and pH Data from Open Channels

View more information
£69.29
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.