• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

ASTM D 5819 : 2005 : R2012

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Standard Guide for Selecting Test Methods for Experimental Evaluation of Geosynthetic Durability

Available format(s)

Hardcopy , PDF

Superseded date

11-11-2014

Language(s)

English

Published date

01-07-2012

1.1This guide covers a designer/specifier through a systematic determination of those factors of the appropriate application environment that may affect the post-construction service life of a geosynthetic. Subsequently, test methods are recommended to facilitate an experimental evaluation of the durability of geosynthetics in a specified environment so that the durability can be considered in the design process.

TABLE 1 FunctionsA and Other Performance CharacteristicsB

ContainmentB (C)—A geosynthetic provides containment when it encapsulates or surrounds materials such as sand, rocks, and fresh concrete.C

FiltrationA (F)—A geosynthetic performs the filtration function when the equilibrium geotextile-to-soil system allows for adequate liquid flow with limited soil loss across the plane of the geotextile over a service lifetime compatible with the application under consideration.

Fluid BarrierA (FB)—A geosynthetic performs the fluid barrier function when it essentially eliminates the migration of fluids through it.

Fluid TransmissionA (a.k.a. drainage)—A geosynthetic performs the fluid transmission function when the equilibrium geotextile-to-soil system allows for adequate flow with limited soil loss within the plane of the geotextile over a service lifetime compatible with the application under consideration.

InsulationB (I)—A geosynthetic provides insulation when it reduces the passage of heat, electricity, or sound.

ProtectionA (P)—A geosynthetic, placed between two materials, performs the protection function when it alleviates or distributes stresses and strains transmitted to the material to be protected.

ReinforcementA (R)—A geosynthetic performs the reinforcement function when it provides often synergistic improvement of a total system's strength created by the introduction of a tensile force into a soil (good in compression but poor in tension) or other disjointed and separated material.

ScreeningB (Scr)—A geosynthetic, placed across the path of a flowing fluid (ground water, surface water, wind) carrying particles in suspension, provides screening when it retains some or all soil fine particles while allowing the fluid to pass through. After some period of time, particles accumulate against the screen which requires that the screen be able to withstand pressures generated by the accumulated particles and the increasing fluid pressure.

SeparationA (S)—A geosynthetic placed between dissimilar materials so that the integrity and functioning of both materials can remain intact or be improved performs the separation function.

Surface StabilizationB (SS)—A geosynthetic, placed on a soil surface, provides surface stabilization when it restricts movement and prevents dispersion of surface soil particles subjected to erosion actions (rain, wind), often while allowing or promoting vegetative growth.

Vegetative ReinforcementB (VR)—A geosynthetic provides vegetative reinforcement when it extends the erosion control limits and performance of vegetation.

AFunctions are used in the context of this guide as terms that can be quantitatively described by standard tests or design techniques, or both.
BOther performance characteristics are qualitative descriptions that are not yet supported by standard tests or generally accepted design techniques.

Note—during the placement of fresh concrete in a geotextile flexible form, the geosynthetic functions temporarily as a filter to allow excess water to escape.

1.2This guide is not intended to address durability issues associated with the manufacturing, handling, transportation, or installation environments.

Committee
D 35
DocumentType
Guide
Pages
11
ProductNote
Reconfirmed 2012
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

ASTM D 6917 : 2016 Standard Guide for Selection of Test Methods for Prefabricated Vertical Drains (PVD)
ASTM D 8203 : 2018 Standard Test Method for Determination of the Horizontal Water Flow Rate of a Geosynthetic Screening Material, Product, or Device

View more information
£69.29
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.