ASTM D 7032 : 2015

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Standard Specification for Establishing Performance Ratings for Wood-Plastic Composite and Plastic Lumber Deck Boards, Stair Treads, Guards, and Handrails
Available format(s)

Hardcopy , PDF

Superseded date

18-02-2016

Language(s)

English

Published date

01-12-2015

1.1This specification covers the procedures to establish a performance rating for wood-plastic composite (WPC) deck boards. This specification also defines the procedures to establish a performance rating for WPC guards and handrails. The purpose of this specification is to establish the basis for code recognition of these products or systems in exterior applications where combustible construction is allowed (see X1.1).

Note 1:While WPCs may contain wood fiber, the presence of wood fiber in the composite is not required by this standard. Other lignocellulosic materials may be used. For WPC deck boards and guardrail systems evaluated according to this standard, the structural, physical, and fire attributes may or may not exhibit similarity to those of wood due to the presence, type, and quantity of plastic(s) in the composite. WPCs should not be assumed to behave similarly to wood. For example, to address the influence of plastic in the composite, special considerations in the standard address sensitivity to temperature, ultraviolet (UV) exposure, and freeze-thaw resistance.

1.1.1The plastic component of wood-plastic composites and plastic lumber covered by this specification shall consist primarily of thermoplastics.

1.2Deck boards, stair treads, guards, and handrails covered by this specification are permitted to be of any code compliant shape and thickness (solid or non-solid).

1.3A deck board, and a deck board used as a stair tread, are assigned a span rating indicating its ability to comply with model code specified functions identified for its specific end use. A guard or handrail is recognized for its ability to meet minimum code requirements specified in the appropriate model building code.

1.4Wood-plastic composites and plastic lumber are produced in a broad range of fiber and/or resin formulations. It is recognized that the performance requirements in this specification are valid for any material or combination of materials used as deck boards, stair treads, guards, or handrails.

1.5Details of manufacturing processes are beyond the scope of this specification.

1.6The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.7This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use.

1.8Table of Contents:

Section

Scope

1

Referenced Documents

2

Terminology

3

General Requirements

4

 Sampling

4.1

 Sample Size

4.2

 Conditioning

4.3

 Flexural Tests

4.4

 Temperature and Moisture Effects

4.5

 Ultraviolet (UV) Resistance Test

4.6

 Freeze-Thaw Resistance Test

4.7

 Biodeterioration Tests

4.8

 Fire Performance Tests

4.9

Deck Board Performance Requirements

5

 General

5.1

 Flexural Performance Tests

5.2

 Determination of the Unadjusted Allowable Load

5.3

 Creep-Recovery Test

5.4

 Mechanical Fastener Holding Tests

5.5

 Slip Resistance Test

5.6

Guard and Handrail Performance Requirements

6

 General

6.1

 Guardrail System Test Requirements

6.2

  One- and Two-Family Dwelling Requirements

6.2.1.1

 Handrail Test Requirements (Concentrated Load)

6.3

Report

7

Independent Inspection

8

Manufacturing Standard

9

Precision and Bias

10

Keywords

11

Two-Span Test Method

Annex A1

Commentary

Appendix X1

Committee
D 07
DocumentType
Standard
Pages
10
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

ASTM E 2957 : 2017 Standard Test Method for Resistance to Wildfire Penetration of Eaves, Soffits and Other Projections
ASTM E 2726/E2726M : 2012 : REV A : R2017 Standard Test Method for Evaluating the Fire-Test-Response of Deck Structures to Burning Brands
ASTM E 2707 : 2015 Standard Test Method for Determining Fire Penetration of Exterior Wall Assemblies Using a Direct Flame Impingement Exposure
ASTM D 7568 : 2017 Standard Specification for Polyethylene-Based Structural-Grade Plastic Lumber for Outdoor Applications

View more information
£62.61
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.