ASTM E 1334 : 1995 : R1999

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Standard Practice for Rating the Serviceability of a Building or Building-Related Facility
Available format(s)

Hardcopy , PDF

Superseded date

11-11-2014

Language(s)

English

Published date

10-10-1999

CONTAINED IN VOL. 04.11, 2014 Specifies a definitive procedure for rating the serviceability of a building or building-related facility, that is, for ascertaining its capability to perform the functions for which it is designed, used, or required to be used.

1.1 This practice is a definitive procedure for rating the serviceability of a building or building-related facility, that is, for ascertaining its capability to perform the functions for which it is designed, used, or required to be used. A separate scale is used for each topic of serviceability. For each topic, a serviceability level is ascertained. Overall serviceability is expressed as a profile of levels (that is, not as a single number), and may be presented as a bar chart.

1.2 This practice is not intended to be used for regulatory purposes.

1.3 This practice can be used to rate the serviceability of a building or building-related facility that has been planned but not yet built, or which is about to be remodelled or rehabilitated, for example, for which single-line drawings and outline specifications have been prepared.

1.4 This practice specifies how to ascertain serviceability levels for a specific building, but not what would cause a building to be rated at a given level. That information is found in standard classifications for specific topics of serviceability that contain a set of requirement and rating scales. This practice and one or more such standard classifications are mutually dependent. Each requires the other. The format of such standard classifications, and of related information, is described in Appendix X1. An example of the scales written for such classifications is given in Appendix X3.

1.5 This practice does not cover building evaluation, building condition reports, nor diagnosis of performance; nor does it cover instruments, tools or quality of measurements for evaluation, condition reports, or diagnosis of performance.

1.6 This practice applies only to facilities that are building constructions, parts thereof, or building-related. While this practice may be useful in rating the serviceability of facilities that are not building constructions, such facilities are outside the scope of this practice.

1.7 The process for creating or adapting a set of classifications for a specific facility type or category is outside the scope of this practice.

1.8 This practice contains the following information:

Section Introduction Scope 1 Referenced Documents 2 Terminology 3 Summary of Practice 4 Significance and Use 5 Procedure 6 Keywords 7 Flow Chart for Rating Serviceability of a Building or Building- Fig. 1 Related Facility for a Specific Purpose Format of a Classification for the Serviceability of a Facility X1 Type or Category Example: Checklist for Tour of a Building X2 Example: Part of a Pair of Serviceability Scales for One Topic X3 Example: Part of a Pair of Matching Serviceability Profiles Pres- X4 ented as Barcharts Example: Titles of Aspects, Topics, and Features X5 Example: List of Common Generic Types of Facility X6

Committee
E 06
DocumentType
Standard Practice
Pages
12
ProductNote
Reconfirmed 1999
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy

ASTM E 1668 : 1995 : REV A : R2018 Standard Classification for Serviceability of an Office Facility for Amenities to Attract and Retain Staff
ASTM E 1667 : 1995 : REV A : R2018 Standard Classification for Serviceability of an Office Facility for Image to the Public and Occupants
ASTM E 1666 : 1995 : REV A : R2018 Standard Classification for Serviceability of an Office Facility for Work Outside Normal Hours or Conditions
ASTM E 1480 : 1992 : R2013 Standard Terminology of Facility Management (Building-Related)
ASTM E 1662 : 1995 : REV A : R2018 Standard Classification for Serviceability of an Office Facility for Sound and Visual Environment
ASTM E 1692 : 1995 : REV A : R2018 Standard Classification for Serviceability of an Office Facility for Change and Churn by Occupants
ASTM E 2320 : 2004 : R2018 Standard Classification for Serviceability of an Office Facility for Thermal Environment and Indoor Air Conditions
ASTM E 631 : 2015 Standard Terminology of Building Constructions
ASTM E 1665 : 1995 : REV A : R2018 Standard Classification for Serviceability of an Office Facility for Facility Protection
ASTM E 1671 : 1995 : REV A : R2018 Standard Classification for Serviceability of an Office Facility for Cleanliness
ASTM E 2166 : 2016 Standard Practice for Organizing and Managing Building Data
ASTM E 1679 : 2013 Standard Practice for Setting the Requirements for the Serviceability of a Building or Building-Related Facility, and for Determining What Serviceability is Provided or Proposed
ASTM E 3035 : 2015 Standard Classification for Facility Asset Component Tracking System (FACTS)
ASTM E 1670 : 1995 : REV A : R2018 Standard Classification for Serviceability of an Office Facility for Management of Operations and Maintenance
ASTM E 1693 : 1995 : R2018 Standard Classification for Serviceability of an Office Facility for Protection of Occupant Assets<rangeref></rangeref >
ASTM E 1661 : 1995 : REV A : R2018 Standard Classification for Serviceability of an Office Facility for Meetings and Group Effectiveness
ASTM E 1660 : 1995 : REV A : R2018 Standard Classification for Serviceability of an Office Facility for Support for Office Work
ASTM E 1701 : 1995 : R2018 Standard Classification for Serviceability of an Office Facility for Manageability
ASTM E 1694 : 1995 : REV A : R2018 Standard Classification for Serviceability of an Office Facility for Special Facilities and Technologies
ASTM E 1663 : 2003 : R2019 Standard Classification for Serviceability of an Office Facility for Typical Office Information Technology

ASTM E 631 : 2015 : REDLINE Standard Terminology of Building Constructions
ISO 6240:1980 Performance standards in building Contents and presentation

View more information
£69.29
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.