1.1This guide describes procedures for obtaining laboratory data concerning the adverse effects of a text material added to growth medium on a certain species of duckweed (Lemna gibba G3) during a 7-day exposure using the static technique. These procedures will probably be useful for conducting toxicity tests with other species of duckweed and other floating vascular plants, although modifications might be necessary.

1.2Special needs or circumstances might also justify modification of this standard. Although using appropriate procedures is more important than following prescribed procedures, results of tests conducted using unusual procedures are not likely to be comparable to results of many other tests. Comparison of results obtained using modified and unmodified versions of these procedures might provide useful information concerning new concepts and procedures for conducting tests with duckweed.

1.3The procedures in this guide are applicable to most chemicals, either individually or in formulations, commercial products, or known mixtures. With appropriate modifications these procedures can be used to conduct tests on temperature and pH and on such other materials as aqueous effluents (see also Guide E1192), leachates, oils, particulate matter, sediments and surface waters. These procedures do not specifically address effluents because to date there is little experience using duckweeds in effluent testing and such tests may pose problems with acclimation of the test organisms to the receiving water. Static tests might not be applicable to materials that have a high oxygen demand, are highly volatile, are rapidly biologically or chemically transformed in aqueous solution, or are removed from test solutions in substantial quantities by the test chambers or organisms during the test.

1.4Results of toxicity tests performed using the procedures in this guide should usually be reported in terms of the 7-day IC50 based on inhibition of growth. In some situations it might only be necessary to determine whether a specific concentration unacceptably affects the growth of the test species or whether the IC50 is above or below a specific concentration. Another end point that may be calculated is the no observed effect concentration (NOEC).

1.5The sections of this guide appear as follows:

  Title

Section

Referenced Documents

2

Terminology

3

Summary of Guide

4

Significance and Use

5

Hazards

6

Apparatus

7

 Facilities

7.1

 Test Chambers

7.2

 Cleaning

7.3

 Acceptability

7.4

Growth Medium

8

 Test Material

9

 General

9.1

 Stock Solution

9.2

 Test Concentration(s)

9.3

Test Organisms

10

 Species

10.1

 Source

10.2

 Stock Culture

10.3

Procedure

11

 Experimental Design

11.1

 Temperature

11.2

 Illumination

11.3

 Beginning the Test

11.4

 Duration of Test

11.5

 Biological Data

11.6

 Other Measurements

11.7

Analytical Methodology

12

Acceptability of Test

13

Calculation of Results

14

Report

15

1.6This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in Section 6.

1.7This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Committee
E 50
DocumentType
Guide
Pages
11
PublisherName
American Society for Testing and Materials
Status
Current
Supersedes

ASTM E 1733 : 2022 Standard Guide for Use of Lighting in Laboratory Testing
ASTM E 2552 : 2016 Standard Guide for Assessing the Environmental and Human Health Impacts of New Compounds for Military Use
ASTM E 1850 : 2004 : R2019 Standard Guide for Selection of Resident Species as Test Organisms for Aquatic and Sediment Toxicity Tests

ASTM E 729 : 1996 : R2014 Standard Guide for Conducting Acute Toxicity Tests on Test Materials with Fishes, Macroinvertebrates, and Amphibians
ASTM E 1023 : 1984 : R2014 Standard Guide for Assessing the Hazard of a Material to Aquatic Organisms and Their Uses
ASTM E 1192 : 2023 Standard Guide for Conducting Acute Toxicity Tests on Aqueous Ambient Samples and Effluents with Fishes, Macroinvertebrates, and Amphibians
ASTM E 943 : 2023 Standard Terminology Relating to Biological Effects and Environmental Fate
ASTM E 943 : 2008 : R2014 Standard Terminology Relating to Biological Effects and Environmental Fate (Withdrawn 2023)
ASTM E 729 : 2023 Standard Guide for Conducting Acute Toxicity Tests on Test Materials with Fishes, Macroinvertebrates, and Amphibians
ASTM E 1023 : 2023 Standard Guide for Assessing the Hazard of a Material to Aquatic Organisms and Their Uses
ASTM E 1192 : 1997 : R2014 Standard Guide for Conducting Acute Toxicity Tests on Aqueous Ambient Samples and Effluents with Fishes, Macroinvertebrates, and Amphibians
ASTM E 729 : 2023 : EDT 1 Standard Guide for Conducting Acute Toxicity Tests on Test Materials with Fishes, Macroinvertebrates, and Amphibians

View more information
£57.60
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.