• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

ASTM E 1623 : 2016 : REDLINE

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Standard Test Method for Determination of Fire and Thermal Parameters of Materials, Products, and Systems Using an Intermediate Scale Calorimeter (ICAL)
Available format(s)

PDF

Superseded date

17-06-2022

Language(s)

English

Published date

08-02-2016

CONTAINED IN VOL. 04.07, 2016 Evaluates the response of materials, products, and assemblies to controlled levels of radiant heat exposure with or without an external ignitor.

1.1This fire-test-response standard assesses the response of materials, products, and assemblies to controlled levels of radiant heat exposure with or without an external ignitor.

1.2The fire-test-response characteristics determined by this test method include the ignitability, heat release rates, mass loss rates, visible smoke development, and gas release of materials, products, and assemblies under well ventilated conditions.

1.3This test method is also suitable for determining many of the parameters or values needed as input for computer fire models. Examples of these values include effective heat of combustion, surface temperature, ignition temperature, and emissivity.

1.4This test method is also intended to provide information about other fire parameters such as thermal conductivity, specific heat, radiative and convective heat transfer coefficients, flame radiation factor, air entrainment rates, flame temperatures, minimum surface temperatures for upward and downward flame spread, heat of gasification, nondimensional heat of gasification (1)2 and the Φ flame spread parameter (see Test Method E1321). While some studies have indicated that this test method is suitable for determining these fire parameters, insufficient testing and research have been done to justify inclusion of the corresponding testing and calculating procedures.

1.5The heat release rate is determined by the principle of oxygen consumption calorimetry, via measurement of the oxygen consumption as determined by the oxygen concentration and flow rate in the exhaust product stream (exhaust duct). The procedure is specified in 11.1. Smoke development is quantified by measuring the obscuration of light by the combustion product stream (exhaust duct).

1.6Specimens are exposed to a constant heat flux in the range of 0 to 50 kW/m2 in a vertical orientation. Hot wires are used to ignite the combustible vapors from the specimen during the ignition and heat release tests. The assessment of the parameters associated with flame spread requires the use of line burners instead of hot wire ignitors.

1.6.1Heat release measurements at low heat flux levels (< 10 kW/m2) require special considerations as described in Section A1.1.6.

1.7This test method has been developed for evaluations, design, or research and development of materials, products, or assemblies, for mathematical fire modeling, or for research and development. The specimen shall be tested in thicknesses and configurations representative of actual end product or system uses.

1.8Limitations of the test method are listed in Section 5.5.

1.9The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.10This standard is used to measure and describe the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials, products, or assemblies under actual fire conditions.

1.11Fire testing is inherently hazardous. Adequate safeguards for personnel and property shall be employed in conducting these tests. Specific information about hazards is given in Section 7.

1.12This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Committee
E 05
DocumentType
Redline
Pages
24
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy

ASTM E 2058 : 2019 Standard Test Methods for Measurement of Material Flammability Using a Fire Propagation Apparatus (FPA)
NFPA 914 : 2015 FIRE PROTECTION OF HISTORIC STRUCTURES
NFPA 556 : 2016 GUIDE ON METHODS FOR EVALUATING FIRE HAZARD TO OCCUPANTS OF PASSENGER ROAD VEHICLES
NFPA 555 : 2017 METHODS FOR EVALUATING POTENTIAL FOR ROOM FLASHOVER
NFPA 18A : 2017 WATER ADDITIVES FOR FIRE CONTROL AND VAPOR MITIGATION
NFPA 556 : 2020 GUIDE ON METHODS FOR EVALUATING FIRE HAZARD TO OCCUPANTS OF PASSENGER ROAD VEHICLES
BS ISO TR 11925-1:1999 Reaction to fire tests. Ignitability of building products subjected to direct impingement of flame Guidance on ignitability
ASTM E 2102 : 2017 : REDLINE Standard Test Method for Measurement of Mass Loss and Ignitability for Screening Purposes Using a Conical Radiant Heater
ASTM E 2067 : 2015 : REDLINE Standard Practice for Full-Scale Oxygen Consumption Calorimetry Fire Tests
ASTM E 1591 : 2013 Standard Guide for Obtaining Data for Fire Growth Models
ISO 14696:2009 Reaction-to-fire tests Determination of fire and thermal parameters of materials, products and assemblies using an intermediate-scale calorimeter (ICAL)

ASTM E 603 : 2017 : REDLINE Standard Guide for Room Fire Experiments
ASTM E 800 : 2014 : REDLINE Standard Guide for Measurement of Gases Present or Generated During Fires
ISO 5660-1:2015 Reaction-to-fire tests Heat release, smoke production and mass loss rate Part 1: Heat release rate (cone calorimeter method) and smoke production rate (dynamic measurement)
ISO 9705:1993 Fire tests Full-scale room test for surface products
ISO 5657:1997 Reaction to fire tests Ignitability of building products using a radiant heat source
ASTM E 906 : 2009 Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using a Thermopile Method
ASTM D 5865 : 2013 : REDLINE TEST METHOD FOR GROSS CALORIFIC VALUE OF COAL AND COKE
ASTM E 662 : 2017-02 TEST METHOD FOR SPECIFIC OPTICAL DENSITY OF SMOKE GENERATED BY SOLID MATERIALS
ISO 5725:1986 Precision of test methods Determination of repeatability and reproducibility for a standard test method by inter-laboratory tests
ASTM E 1354 : 2017 : REDLINE Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen Consumption Calorimeter

View more information
£90.16
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.