We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
  • ASTM E 1944 : 1998 : R2013

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
    Add to Watchlist
    This Standard has been added successfully to your Watchlist.
    Please visit My Watchlist to see all standards that you are watching.
    Please log in or to add this standard to your Watchlist.
    We could not add this standard to your Watchlist.
    Please retry or contact support for assistance.
    You need to be logged in to add this standard to your Watchlist.
    Please log in now or create an account to add.
    You already added this Product in the Watchlist.

    Standard Practice for Describing and Measuring Performance of Laboratory Fourier Transform Near-Infrared (FT-NIR) Spectrometers: Level Zero and Level One Tests

    Available format(s):  Hardcopy, PDF

    Superseded date:  27-04-2021

    Language(s):  English

    Published date:  30-01-2013

    Publisher:  American Society for Testing and Materials

    Add to Watchlist

    Add To Cart

    Abstract - (Show below) - (Hide below)

    CONTAINED IN VOL. 03.06, 2014 Defines two levels of tests to measure the performance of laboratory Fourier transform near infrared (FT-NIR) spectrometers.

    Scope - (Show below) - (Hide below)

    1.1 This practice covers two levels of tests to measure the performance of laboratory Fourier transform near infrared (FT-NIR) spectrometers. This practice applies to the short-wave near infrared region, approximately 800 nm (12 500 cm -1) to 1100 nm (9090.91 cm -1); and the long-wavelength near infrared region, approximately 1100 nm (9090.91 cm -1) to 2500 nm (4000 cm -1). This practice is intended mainly for transmittance measurements of gases and liquids, although it is broadly applicable for reflectance measurements.

    1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

    1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

    General Product Information - (Show below) - (Hide below)

    Committee E 13
    Document Type Standard Practice
    Product Note Reconfirmed 2013
    Publisher American Society for Testing and Materials
    Status Superseded
    Superseded By
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    ASTM D 6122 : 2020 : REV A Standard Practice for Validation of the Performance of Multivariate Online, At-Line, Field and Laboratory Infrared Spectrophotometer, and Raman Spectrometer Based Analyzer Systems
    ASTM E 1655 : 2017 Standard Practices for Infrared Multivariate Quantitative Analysis
    ASTM E 2056 : 2004 : R2016 Standard Practice for Qualifying Spectrometers and Spectrophotometers for Use in Multivariate Analyses, Calibrated Using Surrogate Mixtures
    ASTM E 1421 : 1999 : R2015 : EDT 1 Standard Practice for Describing and Measuring Performance of Fourier Transform Mid-Infrared (FT-MIR) Spectrometers: Level Zero and Level One Tests

    Standards Referencing This Book - (Show below) - (Hide below)

    ASTM E 1421 : 1999 : R2004 Standard Practice for Describing and Measuring Performance of Fourier Transform Mid-Infrared (FT-MIR) Spectrometers: Level Zero and Level One Tests
    ASTM E 1252 : 1998 : R2007 Standard Practice for General Techniques for Obtaining Infrared Spectra for Qualitative Analysis
    ASTM E 1252 : 1998 Standard Practice for General Techniques for Obtaining Infrared Spectra for Qualitative Analysis
    ASTM E 932 : 1989 : R2013 Standard Practice for Describing and Measuring Performance of Dispersive Infrared Spectrometers
    ASTM E 1421 : 1999 : R2009 Standard Practice for Describing and Measuring Performance of Fourier Transform Mid-Infrared (FT-MIR) Spectrometers: Level Zero and Level One Tests
    ASTM E 1421 : 1999 : R2015 : EDT 1 Standard Practice for Describing and Measuring Performance of Fourier Transform Mid-Infrared (FT-MIR) Spectrometers: Level Zero and Level One Tests
    ASTM E 932 : 1989 : R2021 Standard Practice for Describing and Measuring Performance of Dispersive Infrared Spectrometers
    ASTM E 1252 : 1998 : R2021 Standard Practice for General Techniques for Obtaining Infrared Spectra for Qualitative Analysis
    ASTM E 1421 : 1999 Standard Practice for Describing and Measuring Performance of Fourier Transform Mid-Infrared (FT-MIR) Spectrometers Level Zero and Level One Tests
    ASTM E 1252 : 1998 : R2013 : EDT 1 Standard Practice for General Techniques for Obtaining Infrared Spectra for Qualitative Analysis
    ASTM E 1252 : 1998 : R2002 Standard Practice for General Techniques for Obtaining Infrared Spectra for Qualitative Analysis
    ASTM E 168 : 2016 Standard Practices for General Techniques of Infrared Quantitative Analysis
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective