ASTM E 222 : 2017

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Standard Test Methods for Hydroxyl Groups Using Acetic Anhydride Acetylation
Available format(s)

Hardcopy , PDF

Superseded date

13-06-2023

Language(s)

English

Published date

22-02-2019

These test methods cover the determination of hydroxyl groups attached to primary and secondary carbon atoms in aliphatic and alicyclic compounds and phenols.

1.1These test methods cover the determination of hydroxyl groups attached to primary and secondary carbon atoms in aliphatic and alicyclic compounds and phenols.

1.2Three test methods are given as follows:

Sections

Test Method A (Pressure Bottle Method)

8 – 14

Test Method B (Reflux Method)

16 – 22

Test Method C (Perchloric Acid Catalyzed Method)

24 – 30

1.2.1Test Method A is recommended for general use. Test Method B is included to give a standard procedure for the method that has been used widely. Test Method C is recommended when the results are required in a minimum period of time or where ambient temperature for the reaction is desired.

1.2.2The results obtained using Test Methods A and B will be essentially the same, but the results obtained using Test Method C will be higher (up to approximately 4 % relative) than those obtained using the other two methods.

1.2.3Statements on precision are included with each test method. The precision of Test Methods A and C is consistent over a wide range of hydroxyl content (tested over hydroxyl number range of 250 to 1600), whereas Test Method B is less precise at the higher hydroxyl content level than it is at the lower hydroxyl content level. In general, Test Method A is approximately two-fold as precise as Test Method C. Test Method B has approximately the same precision as Test Method C at the lower hydroxyl content level but poorer precision at the higher hydroxyl content level.

1.2.4The interferences are essentially the same for the three methods. Some compounds can be analyzed using Test Methods A or B but not using Test Method C because of interfering reactions of the strong acid catalyst with the compound being analyzed or the acetate product formed in the determination. However, because of its increased reactivity, Test Method C is applicable for determination of some compounds, particularly sterically hindered secondary alcohols, which react too slowly or not at all in Test Methods A and B.

Note 1:Other methods for determination of hydroxyl groups are given in Test Methods D1957, D2195, E326, E335, and E567.

1.3The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.4Review the current appropriate Safety Data Sheets (SDS) for detailed information concerning toxicity, first aid procedures, and safety precautions.

1.5This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazards statements are given in Section 7.

1.6This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Committee
D 16
DocumentType
Test Method
Pages
8
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

ASTM D 6342 : 2022 Standard Practice for Polyurethane Raw Materials: Determining Hydroxyl Number of Polyols by Near Infrared (NIR) Spectroscopy
ASTM E 1899 : 2016 Standard Test Method for Hydroxyl Groups Using Reaction with <emph type="ital">p</emph >-Toluenesulfonyl Isocyanate (TSI) and Potentiometric Titration with Tetrabutylammonium Hydroxide
ASTM E 1547 : 2009 : R2023 Standard Terminology Relating to Industrial and Specialty Chemicals
ASTM D 4274 : 2023 Standard Test Methods for Testing Polyurethane Raw Materials: Determination of Hydroxyl Numbers of Polyols

ASTM D 2195 : 2000 Standard Test Methods for Pentaerythritol
ASTM D 6809 : 2002 : R2016 Standard Guide for Quality Control and Quality Assurance Procedures for Aromatic Hydrocarbons and Related Materials
ASTM D 6809 : 2020 Standard Guide for Quality Control and Quality Assurance Procedures for Aromatic Hydrocarbons and Related Materials
ASTM E 567 : 1991 Test Method for Tertiary Hydroxyl Groups with Hydrogen Bromide (Withdrawn 1996)
ASTM D 2195 : 2005 Standard Test Methods for Pentaerythritol (Withdrawn 2011)
ASTM D 1957 : 1986 : R1995 : EDT 1 Standard Test Method for Hydroxyl Value of Fatty Oils and Acids
ASTM D 1193 : 1977 : R1983 : EDT 1 Standard Specification for Reagent Water
ASTM D 1193 : 2006 : R2011 Standard Specification for Reagent Water
ASTM D 6809 : 2002 : R2012 Standard Guide for Quality Control and Quality Assurance Procedures for Aromatic Hydrocarbons and Related Materials
ASTM D 1193 : 1991 Standard Specification for Reagent Water
ASTM D 1957 : 1986 : R2001 Standard Test Method for Hydroxyl Value of Fatty Oils and Acids (Withdrawn 2007)
ASTM E 326 : 1996 Test Method for Hydroxyl Groups by Phthalic Anhydride Esterification (Withdrawn 2001)
ASTM D 6809 : 2002 Standard Guide for Quality Control and Quality Assurance Procedures for Aromatic Hydrocarbons and Related Materials
ASTM D 1193 : 1970 Standard Specification For Reagent Water
ASTM D 1193 : 2006 Standard Specification for Reagent Water
ASTM D 1193 : 1999 Standard Specification for Reagent Water
ASTM D 6809 : 2002 : R2007 Standard Guide for Quality Control and Quality Assurance Procedures for Aromatic Hydrocarbons and Related Materials
ASTM D 1193 : 2006 : R2018 Standard Specification for Reagent Water
ASTM E 335 : 1996 Standard Test Method for Hydroxyl Groups by Pyromellitic Dianhydride Esterification (Withdrawn 2003)

View more information
£62.61
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.