• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

ASTM F 1394 : 1992 : R2012

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Standard Test Method for Determination of Particle Contribution from Gas Distribution System Valves
Available format(s)

Hardcopy , PDF

Superseded date

03-12-2023

Language(s)

English

Published date

01-07-2012

CONTAINED IN VOL. 10.04, 2015 Defines gas distribution system components meant for installation into a high-purity gas distribution system.

1.1This test method covers gas distribution system components intended for installation into a high-purity gas distribution system.

1.1.1This test method describes a procedure designed to draw statistically significant comparisons of particulate generation performance of valves tested under aggressive conditions.

1.1.2This test method is not intended as a methodology for monitoring on-going particle performance once a particular valve has been tested.

1.2This test method utilizes a condensation nucleus counter (CNC) applied to in-line gas valves typically used in semiconductor applications. It applies to automatic and manual valves of various types (such as diaphragms or bellows), 6.3 through 12.7-mm (1/4through 1/2-in.) size. For applications of this test method to larger valves, see the table in the appendix.

1.2.1Valves larger than 12.7 mm (1/2in.) can be tested by this methodology. The test stand must be sized accordingly. Components larger than 12.7 mm (1/2in.) should be tested while maintaining a Reynolds number of 20 000 to 21 000. This is the Reynolds number for 12.7-mm (1/2-in.) components tested at a velocity of 30.5 m/s (100 ft/s).

1.3Limitations:

1.3.1This test method is applicable to total particle count greater than the minimum detection limit (MDL) of the condensation nucleus particle counter and does not consider classifying data into various size ranges.

1.3.1.1It is questionable whether significant data can be generated from nondynamic components (such as fittings and short lengths of tubing) to compare, with statistical significance, to the data generated from the spool piece. For this reason, this test method cannot reliably support comparisons between these types of components.

1.3.1.2If detection or classification of particles, or both, in the size range of laser particle counter (LPC) technology is of interest, an LPC can be utilized for testing components. Flow rates, test times, sampling apparatus, and data analysis outlined in this test method do not apply for use with an LPC. Because of these variations, data from CNCs are not comparable to data from LPCs.

1.3.2This test method specifies flow and mechanical stress conditions in excess of those considered typical. These conditions should not exceed those recommended by the manufacturer. Actual performance under normal operating conditions may vary.

1.3.3The test method is limited to nitrogen or clean dry air. Performance with other gases may vary.

1.3.4This test method is intended for use by operators who understand the use of the apparatus at a level equivalent to six months of experience.

1.3.5The appropriate particle counter manufacturer's operating and maintenance manuals should be consulted when using this test method.

1.4The values stated in SI units are to be regarded as the standard. The inch-pound units given in parentheses are for information only.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in Section 6, Hazards.

Committee
F 01
DocumentType
Test Method
Pages
27
ProductNote
Reconfirmed 2012
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

FED-STD-209 Revision E:1992 AIRBORNE PARTICULATE CLEANLINESS CLASSES IN CLEANROOMS AND CLEAN ZONES

View more information
£90.16
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.