• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

ASTM G 72/G72M : 2015

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Standard Test Method for Autogenous Ignition Temperature of Liquids and Solids in a High-Pressure Oxygen-Enriched Environment
Available format(s)

Hardcopy , PDF

Superseded date

15-02-2024

Language(s)

English

Published date

08-12-2015

1.1This test method covers the determination of the temperature at which liquids and solids will spontaneously ignite. These materials must ignite without application of spark or flame in a high-pressure oxygen-enriched environment.

1.2This test method is intended for use at pressures of 2.1 to 20.7 MPa [300 to 3000 psi]. The pressure used in the description of the method is 10.3 MPa [1500 psi], and is intended for applicability to high pressure conditions. The test method, as described, is for liquids or solids with ignition temperature in the range from 60 to 500 °C [140 to 932 °F].

Note 1:Test Method G72/G72M normally utilizes samples of approximately 0.20 +/- 0.03-g mass, a starting pressure of 10.3 MPa [1500 psi] and a temperature ramp rate of 5 °C/min. However, Autogenous Ignition Temperatures (AIT) can also be obtained under other test conditions. Testing experience has shown that AIT testing of volatile liquids can be influenced by the sample pre-conditioning and the sample mass. This will be addressed in the standard as Special Case 1 in subsection 8.2.2. Testing experience has also shown that AIT testing of solid or non-volatile liquid materials at low pressures (i.e., < 2.1 MPa) can be significantly influenced by the sample mass and the temperature ramp rate. This will be addressed in the standard as Special Case 2, in subsection 8.2.3. Since the AIT of a material is dependent on the sample mass/configuration and test conditions, any departure from the standard conditions normally used for Test Method G72/G72M testing should be clearly indicated in the test report.

1.3This test method is for high-pressure pure oxygen. The test method may be used in atmospheres from 0.5 % to 100 % oxygen.

1.4An apparatus suitable for these requirements is described. This test method could be applied to higher pressures and materials of higher ignition temperature. If more severe requirements or other oxidizers than those described are desired, care must be taken in selecting an alternative safe apparatus capable of withstanding the conditions.

1.5The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.

1.6This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Committee
G 04
DocumentType
Test Method
Pages
7
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

ASTM E 177 : 1990 : REV A : R1996 Standard Practice for Use of the Terms Precision and Bias in ASTM Test Methods
ASTM D 1193 : 1977 : R1983 : EDT 1 Standard Specification for Reagent Water
ASTM E 691 : 2020 Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method
ASTM E 691 : 2019 : EDT 1 Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method
ASTM E 691 : 2023 Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method
ASTM D 1193 : 2006 : R2011 Standard Specification for Reagent Water
ASTM E 691 : 2022 Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method
ASTM E 691 : 2009 Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method
ASTM D 1193 : 1991 Standard Specification for Reagent Water
ASTM E 691 : 2021 Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method
ASTM D 1193 : 1970 Standard Specification For Reagent Water
ASTM D 1193 : 2006 Standard Specification for Reagent Water
ASTM D 1193 : 1999 Standard Specification for Reagent Water
ASTM D 1193 : 2006 : R2018 Standard Specification for Reagent Water

View more information
£62.61
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.