    Fire tests on building materials and structures Methods for determination of the contribution of components to the fire resistance of a structure

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  29-05-1987

    Publisher:  British Standards Institution

    Add to Watchlist

    Add To Cart

    Abstract - (Show below) - (Hide below)

    Detailed test requirements for the contribution made by suspended ceilings to beams and by intumescent seals to doorsets and shutter assemblies.

    Scope - (Show below) - (Hide below)

    This Part of BS 476 describes procedures for determining the contribution made by components to the total fire resistance of a structure or other elements used in conjunction with them when subjected to the relevant heating and pressure conditions specified in BS 476-20. This Part provides the requirements for specimen selection and/or its design and construction, the edge conditions, the equipment including any special apparatus or instrumentation, and the procedures and criteria as they apply to components which make a contribution to the fire resistance of a complete assembly. The methods are applicable to suspended ceilings protecting steel beams and intumescent seals for use in conjunction with single-acting, latched timber fire resisting door assemblies.

    NOTE The titles of the publications referred to in this standard are listed on the inside back cover.

    General Product Information - (Show below) - (Hide below)

    Committee FSH/22
    Development Note Together with BS 476-20(1987), BS 476-21(1987), BS 476-22(1987) and BS 476-24(1987), it supersedes BS 476-8(1972). Supersedes 85/41321 DC and 96/540442 DC. (06/2004) Reviewed and confirmed by BSI, December 2011. (11/2011)
    Document Type Standard
    Publisher British Standards Institution
    Status Current
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    PD 6512-3:1987 Use of elements of structural fire protection with particular reference to the recommendations given in BS 5588 \'Fire precautions in the design and construction of buildings\' Guide to the fire performance of glass
    BS 5268-4.2(1990) : 1990 STRUCTURAL USE OF TIMBER - FIRE RESISTANCE OF TIMBER STRUCTURES - RECOMMENDATION FOR CALCULATING FIRE RESISTANCE OF TIMBER STUD WALLS AND JOISTED FLOOR CONSTRUCTIONS
    07/30147204 DC : 0 BS 476-10 - FIRE TESTS ON BUILDING MATERIALS AND STRUCTURES - PART 10: GUIDE TO THE PRINCIPLES, SELECTION, ROLE AND APPLICATION OF FIRE TESTING AND THEIR OUTPUTS
    BS 5588-1:1990 FIRE PRECAUTIONS IN THE DESIGN, CONSTRUCTION AND USE OF BUILDINGS - PART 1: CODE OF PRACTICE FOR RESIDENTIAL BUILDINGS
    BS 5588-10:1991 FIRE PRECAUTIONS IN THE DESIGN, CONSTRUCTION AND USE OF BUILDINGS - PART 10: CODE OF PRACTICE FOR SHOPPING COMPLEXES
    02/714116 DC : DRAFT DEC 2002 BS 6230:1991 - INSTALLATION OF GAS-FIRED FORCED CONVECTION AIR CONVECTION AIR HEATERS FOR COMMERCIAL AND INDUSTRIAL SPACE HEATING (2ND AND 3RD FAMILY GASES)
    I.S. 813:2014+A1:2017 DOMESTIC GAS INSTALLATIONS (EDITION 3) AND AMENDMENT 1:2017
    BS 6203:2003 Guide to fire characteristics and fire performance of expanded polystyrene materials (EPS and XPS) used in building applications
    BS 6203:1991 GUIDE TO FIRE CHARACTERISTICS AND FIRE PERFORMANCE OF EXPANDED POLYSTYRENE MATERIALS USED IN BUILDING APPLICATIONS
    BS 5588-6:1991 FIRE PRECAUTIONS IN THE DESIGN, CONSTRUCTION AND USE OF BUILDINGS - PART 6: CODE OF PRACTICE FOR PLACES OF ASSEMBLY
    BS 8290-1:1991 SUSPENDED CEILINGS - CODE OF PRACTICE FOR DESIGN
    BS 5588-8:1988 FIRE PRECAUTIONS IN THE DESIGN AND CONSTRUCTION OF BUILDINGS - CODE OF PRACTICE FOR MEANS OF ESCAPE FOR DISABLED PEOPLE
    11/30244843 DC : 0 BS 5306-4:2001+A1 - FIRE EXTINGUISHING INSTALLATIONS AND EQUIPMENT ON PREMISES - PART 4: SPECIFICATION FOR CARBON DIOXIDE SYSTEMS
    BS 5588-2(1985) : 1985 FIRE PRECAUTIONS IN THE DESIGN AND CONSTRUCTION OF BUILDINGS - CODE OF PRACTICE FOR SHOPS
    BS 5306-4(2001) : 2001 FIRE EXTINGUISHING INSTALLATIONS AND EQUIPMENT ON PREMISES - PART 4: SPECIFICATION FOR CARBON DIOXIDE SYSTEMS
    BS 5628-3:2001 CODE OF PRACTICE FOR USE OF MASONRY - PART 3: MATERIALS AND COMPONENTS, DESIGN AND WORKMANSHIP
    BS 5502-23:2004 Buildings and structures for agriculture Fire precautions. Code of practice
    BS 6230:2005 SPECIFICATION FOR INSTALLATION OF GAS-FIRED FORCED CONVECTION AIR HEATERS FOR COMMERCIAL AND INDUSTRIAL SPACE HEATING (2ND AND 3RD FAMILY GASES)
    BS 5588-8:1999 FIRE PRECAUTIONS IN THE DESIGN, CONSTRUCTION AND USE OF BUILDINGS - PART 8: CODE OF PRACTICE FOR MEANS OF ESCAPE FOR DISABLED PEOPLE
    PD 7974-3:2011 Application of fire safety engineering principles to the design of buildings Structural response and fire spread beyond the enclosure of origin
    BS 5588-5:1991 FIRE PRECAUTIONS IN THE DESIGN, CONSTRUCTION AND USE OF BUILDINGS - CODE OF PRACTICE FOR FIREFIGHTING STAIRS AND LIFTS
    BS 5306-5.1:1992 Code of practice for fire extinguishing installations and equipment on premises. Halon systems Specification for halon 1301 total flooding systems
    BS 5588-9:1999 FIRE PRECAUTIONS IN THE DESIGN, CONSTRUCTION AND USE OF BUILDINGS - PART 9: CODE OF PRACTICE FOR VENTILATION AND AIR CONDITIONING DUCTWORK
    BS 476-10:2009 Fire tests on building materials and structures Guide to the principles, selection, role and application of fire testing and their outputs
    BS 5427(2016) : 2016 CODE OF PRACTICE FOR THE USE OF PROFILED SHEET FOR ROOF AND WALL CLADDING ON BUILDINGS
    BS 5908:1990 CODE OF PRACTICE FOR FIRE PRECAUTIONS IN THE CHEMICAL AND ALLIED INDUSTRIES
    BS 6230:1991 SPECIFICATION FOR INSTALLATION OF GAS-FIRED FORCED CONVECTION AIR HEATERS FOR COMMERCIAL AND INDUSTRIAL SPACE HEATING (2ND FAMILY GASES)
    BS 6230:2011 SPECIFICATION FOR INSTALLATION AND MAINTENANCE OF GAS FIRED FORCED CONVECTION AIR HEATERS FOR COMMERCIAL AND INDUSTRIAL SPACE HEATING (2ND AND 3RD FAMILY GASES)
    BS 5306-4:2001+A1:2012 Fire extinguishing installations and equipment on premises Specification for carbon dioxide systems
    11/30229803 DC : 0 BS 6230 - SPECIFICATION FOR INSTALLATION OF GAS-FIRED FORCED CONVECTION AIR HEATERS FOR COMMERCIAL AND INDUSTRIAL SPACE HEATING (2ND AND 3RD FAMILY GASES)
    15/30095322 DC : 0 BS 5427 - CODE OF PRACTICE FOR THE USE OF PROFILED SHEET FOR ROOF AND WALL CLADDING ON BUILDINGS
    BS 476-10:1983 FIRE TESTS ON BUILDING MATERIALS AND STRUCTURES - GUIDE TO THE PRINCIPLES AND APPLICATION OF FIRE TESTING
    BS 476-21:1987 Fire tests on building materials and structures Methods for determination of the fire resistance of loadbearing elements of construction
    BS 476-20:1987 FIRE TESTS ON BUILDING MATERIALS AND STRUCTURES - PART 20: METHOD FOR DETERMINATION OF THE FIRE RESISTANCE OF ELEMENTS OF CONSTRUCTION (GENERAL PRINCIPLES)
    BS 1892-2.10:1990 GYMNASIUM EQUIPMENT - PARTICULAR REQUIREMENTS - SPECIFICATION FOR SAFETY REQUIREMENTS FOR MATS, MATTRESSES AND LANDING AREAS
    I.S. 813:2014 DOMESTIC GAS INSTALLATIONS (EDITION 3) AND AMENDMENT 1:2017
    PD 7974-3:2003 APPLICATION OF FIRE SAFETY ENGINEERING PRINCIPLES TO THE DESIGN OF BUILDINGS - PART 3: STRUCTURAL RESPONSE AND FIRE SPREAD BEYOND THE ENCLOSURE OF ORIGIN (SUB-SYSTEM 3)
    BS 5588-11:1997 Fire precautions in the design, construction and use of buildings Code of practice for shops, offices, industrial, storage and other similar buildings
    BS 1892-4:2003 SPORTS MATS - PART 4: SPECIFICATION FOR COMBAT MATS
    BS 5427-1:1996 CODE OF PRACTICE FOR THE USE OF PROFILED SHEET FOR ROOF AND WALL CLADDING ON BUILDINGS - DESIGN
    BS 8214:1990 CODE OF PRACTICE FOR FIRE DOOR ASSEMBLIES WITH NON-METALLIC LEAVES
    PD 6520:1988 Guide to fire test methods for building materials and elements of construction
    BS 5588-9:1989 FIRE PRECAUTIONS IN THE DESIGN AND CONSTRUCTION OF BUILDINGS - CODE OF PRACTICE FOR VENTILATION AND AIR CONDITIONING DUCTWORK
    I.S. 325-2:1995 CODE OF PRACTICE FOR USE OF MASONRY - PART 2: MASONRY CONSTRUCTION
    PD 6686:2006 GUIDANCE ON DIRECTIVES, REGULATIONS AND STANDARDS RELATED TO PREVENTION OF FIRE AND EXPLOSION IN THE PROCESS INDUSTRIES
    05/30131954 DC : DRAFT APR 2005 BS 5628-3 - CODE OF PRACTICE FOR THE USE OF MASONRY - PART 3: MATERIALS AND COMPONENTS, DESIGN AND WORKMANSHIP
    BS 5588-3(1983) : 1983 FIRE PRECAUTIONS IN THE DESIGN AND CONSTRUCTION OF BUILDINGS - CODE OF PRACTICE FOR OFFICE BUILDINGS
    BS 1892-3:2003 Gymnasium equipment Sports mats. Specification for fire safety requirements for mats, mattresses and landing areas
    BS 476-22:1987 Fire tests on building materials and structures Method for determination of the fire resistance of non-loadbearing elements of construction

    Standards Referencing This Book - (Show below) - (Hide below)

    BS 476-20:1987 FIRE TESTS ON BUILDING MATERIALS AND STRUCTURES - PART 20: METHOD FOR DETERMINATION OF THE FIRE RESISTANCE OF ELEMENTS OF CONSTRUCTION (GENERAL PRINCIPLES)
    BS 476-21:1987 Fire tests on building materials and structures Methods for determination of the fire resistance of loadbearing elements of construction
    BS 476-24:1987 Fire tests on building materials and structures Method for determination of the fire resistance of ventilation ducts
    BS 476-22:1987 Fire tests on building materials and structures Method for determination of the fire resistance of non-loadbearing elements of construction
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective