BS 5306-5.2:1984
|
Code of practice for fire extinguishing installations and equipment on premises. Halon systems Halon 1211 total flooding systems |
BS 1566-1:1984
|
COPPER INDIRECT CYLINDERS FOR DOMESTIC PURPOSES - SPECIFICATION FOR DOUBLE FEED INDIRECT CYLINDERS |
BS 5516-2:2004
|
PATENT GLAZING AND SLOPING GLAZING FOR BUILDINGS - PART 2: CODE OF PRACTICE FOR SLOPING GLAZING |
BS 5258-2:1975
|
SAFETY OF DOMESTIC GAS APPLIANCES - COOKING APPLIANCES |
BS 5588-11:1997
|
Fire precautions in the design, construction and use of buildings Code of practice for shops, offices, industrial, storage and other similar buildings |
BS 8303-1:1994
|
INSTALLATION OF DOMESTIC HEATING AND COOKING APPLIANCES BURNING SOLID MINERAL FUELS - INSTALLATION OF DOMESTIC HEATING AND COOKING APPLIANCES BURNING SOLID MINERAL FUELS - SPECIFICATION FOR THE DESIGN OF INSTALLATIONS |
PD 6512-3:1987
|
USE OF ELEMENTS OF STRUCTURAL FIRE PROTECTION WITH PARTICULAR REFERENCE TO THE RECOMMENDATIONS GIVEN IN BS 5588 'FIRE PRECAUTIONS IN THE DESIGN AND CONSTRUCTION OF BUILDINGS' - GUIDE TO THE FIRE PERFORMANCE OF GLASS |
BS 6229:1982
|
CODE OF PRACTICE FOR FLAT ROOFS WITH CONTINUOUSLY SUPPORTED COVERINGS |
BS 7258-1:1990
|
LABORATORY FUME CUPBOARDS - SPECIFICATION FOR SAFETY AND PERFORMANCE |
BS 5258-10:1980
|
SAFETY OF DOMESTIC GAS APPLIANCES - FLUELESS SPACE HEATERS (EXCLUDING CATALYTIC COMBUSTION HEATERS) (3RD FAMILY GASES) |
BS 3958-3:1985
|
Thermal insulating materials Metal mesh faced man-made mineral fibre mattresses |
DEFSTAN 02-802(PT7)/1(2000) : 2000
|
REQUIREMENTS FOR ACOUSTIC AND THERMAL INSULATION MATERIAL - PART 7: MINERAL WOOL PRODUCTS LOOSE ROCK WOOL |
BS 5306-5.1(1982) : 1982
|
FIRE EXTINGUISHING INSTALLATIONS AND EQUIPMENT ON PREMISES - HALON SYSTEMS - HALON 1301 TOTAL FLOODING SYSTEMS |
BS 3143-1:1985
|
ROAD DANGER LAMPS - SPECIFICATION FOR KEROSINE BURNING LAMPS |
BS 5258-11:1980
|
SAFETY OF DOMESTIC GAS APPLIANCES - FLUELESS CATALYTIC COMBUSTION HEATERS (3RD FAMILY GASES) |
BS 5234(1975) : 1975
|
CODE OF PRACTICE INTERNAL NON LOADBEARING PARTITIONING |
BS 6351-2:1983
|
ELECTRIC SURFACE HEATING - GUIDE TO THE DESIGN OF ELECTRIC SURFACE HEATING SYSTEMS |
BS 5871(1980) : 1980
|
CODE OF PRACTICE FOR THE INSTALLATION OF GAS FIRES CONVECTORS AND FIRE BACK BOILERS (2ND FAMILY GASES) |
BS MA 94:1981
|
SPECIFICATION FOR THERMAL INSULATION FOR MARINE PIPING SYSTEMS |
EEMUA 147 : 2016
|
RECOMMENDATIONS FOR REFRIGERATED LIQUEFIED GAS STORAGE TANKS |
BS 6266:1982
|
CODE OF PRACTICE FOR FIRE PROTECTION FOR ELECTRONIC DATA PROCESSING INSTALLATIONS |
BS 6351-3:1983
|
ELECTRIC SURFACE HEATING - CODE OF PRACTICE FOR THE INSTALLATION, TESTING AND MAINTENANCE OF ELECTRIC SURFACE HEATING SYSTEMS |
BS 7186:1989
|
SPECIFICATION FOR NON-DOMESTIC GAS-FIRED OVERHEAD RADIANT TUBE HEATERS |
BS 5588-10:1991
|
FIRE PRECAUTIONS IN THE DESIGN, CONSTRUCTION AND USE OF BUILDINGS - PART 10: CODE OF PRACTICE FOR SHOPPING COMPLEXES |
BS 699:1984
|
SPECIFICATION FOR COPPER DIRECT CYLINDERS FOR DOMESTIC PURPOSES |
DEFSTAN 02-802(PT6)/1(2000) : 2000
|
REQUIREMENTS FOR ACOUSTIC AND THERMAL INSULATION MATERIAL - PART 6: MINERAL WOOL PRODUCTS ROCK WOOL MATTRESSES FOR GAS TURBINE UPTAKES |
BS 5258-7:1977
|
SAFETY OF DOMESTIC GAS APPLIANCES - STORAGE WATER HEATERS |
NFPA 502 : 2017
|
ROAD TUNNELS, BRIDGES, AND OTHER LIMITED ACCESS HIGHWAYS |
BS 5410-1:2014
|
CODE OF PRACTICE FOR OIL FIRING - PART 1: INSTALLATIONS UP TO 45 KW OUTPUT CAPACITY FOR SPACE HEATING AND HOT WATER SUPPLY PURPOSES |
BS 7671(2008) : 2018
|
REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
BS 6164:2011
|
CODE OF PRACTICE FOR HEALTH AND SAFETY IN TUNNELING IN THE CONSTRUCTION INDUSTRY |
BS 5422:2001
|
Method for specifying thermal insulating materials for pipes, tanks, vessels, ductwork and equipment operating within the temperature range -40°C to +700°C |
BS 6203:2003
|
GUIDE TO FIRE CHARACTERISTICS AND FIRE PERFORMANCE OF EXPANDED POLYSTYRENE MATERIALS (EPS AND XPS) USED IN BUILDING APPLICATIONS |
BS 6203:1991
|
GUIDE TO FIRE CHARACTERISTICS AND FIRE PERFORMANCE OF EXPANDED POLYSTYRENE MATERIALS USED IN BUILDING APPLICATIONS |
BS 8202-1:1995
|
COATINGS FOR FIRE PROTECTION OF BUILDING ELEMENTS - PART 1: CODE OF PRACTICE FOR THE SELECTION AND INSTALLATION OF SPRAYED MINERAL COATINGS |
PD 6686:2006
|
GUIDANCE ON DIRECTIVES, REGULATIONS AND STANDARDS RELATED TO PREVENTION OF FIRE AND EXPLOSION IN THE PROCESS INDUSTRIES |
BS 5258-12:1980
|
SAFETY OF DOMESTIC GAS APPLIANCES - DECORATIVE GAS LOG AND OTHER FUEL EFFECT APPLIANCES (2ND AND 3RD FAMILY GASES) |
BS 6262:1982
|
CODE OF PRACTICE FOR GLAZING FOR BUILDINGS |
BS 5588-6:1991
|
FIRE PRECAUTIONS IN THE DESIGN, CONSTRUCTION AND USE OF BUILDINGS - PART 6: CODE OF PRACTICE FOR PLACES OF ASSEMBLY |
BS 5546:2010
|
SPECIFICATION FOR INSTALLATION AND MAINTENANCE OF GAS-FIRED WATER-HEATING APPLIANCES OF RATED INPUT NOT EXCEEDING 70 KW NET |
BS 5306-6.1:1988
|
FIRE EXTINGUISHING INSTALLATIONS AND EQUIPMENT ON PREMISES - PART 6: FOAM SYSTEMS - SECTION 6.1: SPECIFICATION FOR LOW EXPANSION FOAM SYSTEMS |
07/30147204 DC : 0
|
BS 476-10 - FIRE TESTS ON BUILDING MATERIALS AND STRUCTURES - PART 10: GUIDE TO THE PRINCIPLES, SELECTION, ROLE AND APPLICATION OF FIRE TESTING AND THEIR OUTPUTS |
BS 8290-1:1991
|
SUSPENDED CEILINGS - CODE OF PRACTICE FOR DESIGN |
BS 6262-3:2005
|
GLAZING FOR BUILDINGS - PART 3: CODE OF PRACTICE FOR FIRE, SECURITY AND WIND LOADING |
BS 6350:1983
|
SPECIFICATION FOR GAS HEATED FISH AND CHIP FRYING RANGES |
BS 5588-8:1988
|
FIRE PRECAUTIONS IN THE DESIGN AND CONSTRUCTION OF BUILDINGS - CODE OF PRACTICE FOR MEANS OF ESCAPE FOR DISABLED PEOPLE |
BS 4422-2:1971
|
GLOSSARY OF TERMS ASSOCIATED WITH FIRE - BUILDING MATERIALS AND STRUCTURES |
11/30244843 DC : 0
|
BS 5306-4:2001+A1 - FIRE EXTINGUISHING INSTALLATIONS AND EQUIPMENT ON PREMISES - PART 4: SPECIFICATION FOR CARBON DIOXIDE SYSTEMS |
BS 5588-2(1985) : 1985
|
FIRE PRECAUTIONS IN THE DESIGN AND CONSTRUCTION OF BUILDINGS - CODE OF PRACTICE FOR SHOPS |
BS 5427:1976
|
CODE OF PRACTICE FOR PERFORMANCE AND LOADING CRITERIA FOR PROFILED SHEETING IN BUILDING |
04/30085945 DC : DRAFT NOV 2004
|
BS 1703 - REFUSE CHUTES AND HOPPERS - SPECIFICATION |
BS 5970:1981
|
Code of practice for thermal insulation of pipework and equipment (in the temperature range -100°C to +870°C) |
16/30347136 DC : 0
|
BS 8303 - INSTALLATION OF DOMESTIC HEATING AND COOKING APPLIANCES BURNING WOOD, WOODY BIOMASS AND SOLID MINERAL FUELS - SPECIFICATION |
BS 5306-4:1986
|
FIRE EXTINGUISHING INSTALLATIONS AND EQUIPMENT ON PREMISES - SPECIFICATION FOR CARBON DIOXIDE SYSTEMS |
BS 5516:1991
|
CODE OF PRACTICE FOR DESIGN AND INSTALLATION OF SLOPING AND VERTICAL PATENT GLAZING |
BS 5871-2:2005
|
SPECIFICATION FOR THE INSTALLATION AND MAINTENANCE OF GAS FIRES, CONVECTOR HEATERS, FIRE/BACK BOILERS AND DECORATIVE FUEL EFFECT GAS APPLIANCES - PART 2: INSET LIVE FUEL EFFECT GAS FIRES OF HEAT INPUT NOT EXCEEDING 15 KW, AND FIRE/BACK BOILERS (2ND AND 3RD FAMILY GASES) |
BS 5306-4(2001) : 2001
|
FIRE EXTINGUISHING INSTALLATIONS AND EQUIPMENT ON PREMISES - PART 4: SPECIFICATION FOR CARBON DIOXIDE SYSTEMS |
BS 5991:2006
|
SPECIFICATION FOR INDIRECT GAS FIRED FORCED CONVECTION AIR HEATERS WITH RATED HEAT INPUTS GREATER THAN 330 KW BUT NOT EXCEEDING 2 MW FOR INDUSTRIAL AND COMMERCIAL SPACE HEATING - SAFETY AND PERFORMANCE REQUIREMENTS (EXCLUDING ELECTRICAL REQUIREMENTS) (2ND FAMILY GASES) |
BS 5991:1989
|
SPECIFICATION FOR INDIRECT GAS FIRED FORCED CONVECTION AIR HEATERS WITH RATED HEAT INPUTS UP TO 2 MW FOR INDUSTRIAL AND COMMERCIAL SPACE HEATING: SAFETY AND PERFORMANCE REQUIREMENTS (EXCLUDING ELECTRICAL REQUIREMENTS) (2ND FAMILY GASES) |
BS 5588-8:1999
|
FIRE PRECAUTIONS IN THE DESIGN, CONSTRUCTION AND USE OF BUILDINGS - PART 8: CODE OF PRACTICE FOR MEANS OF ESCAPE FOR DISABLED PEOPLE |
BS 5345-1:1989
|
CODE OF PRACTICE FOR SELECTION, INSTALLATION & MAINTENANCE OF ELECTRICAL APPARATUS FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES |
BS 5546:2000
|
SPECIFICATION FOR INSTALLATION OF HOT WATER SUPPLIES FOR DOMESTIC PURPOSES, USING GAS-FIRED APPLIANCES OF RATED INPUT NOT EXCEEDING 70 KW |
BS 5990:1990
|
SPECIFICATION FOR DIRECT GAS-FIRED FORCED CONVECTION AIR HEATERS WITH RATED HEAT INPUTS UP TO 2 MW FOR INDUSTRIAL AND COMMERCIAL SPACE HEATING: SA FETY AND PERFORMANCE REQUIREMENTS (EXCLUDING ELECTRICAL REQUIREMENT) (2ND FAMILY GASES) |
PD 7974-3:2011
|
APPLICATION OF FIRE SAFETY ENGINEERING PRINCIPLES TO THE DESIGN OF BUILDINGS - PART 3: STRUCTURAL RESPONSE AND FIRE SPREAD BEYOND THE ENCLOSURE OF ORIGIN |
BS 5588-5:1991
|
FIRE PRECAUTIONS IN THE DESIGN, CONSTRUCTION AND USE OF BUILDINGS - CODE OF PRACTICE FOR FIREFIGHTING STAIRS AND LIFTS |
BS 5978-1:1989
|
SAFETY AND PERFORMANCE OF GAS-FIRED HOT WATER BOILERS (60 KW TO 2 MW INPUT) - SPECIFICATION FOR GENERAL REQUIREMENTS |
BS 6266:2002
|
CODE OF PRACTICE FOR FIRE PROTECTION FOR ELECTRONIC EQUIPMENT INSTALLATIONS |
BS 5588-9:1999
|
FIRE PRECAUTIONS IN THE DESIGN, CONSTRUCTION AND USE OF BUILDINGS - PART 9: CODE OF PRACTICE FOR VENTILATION AND AIR CONDITIONING DUCTWORK |
BS 476-10:2009
|
FIRE TESTS ON BUILDING MATERIALS AND STRUCTURES - PART 10: GUIDE TO THE PRINCIPLES, SELECTION, ROLE AND APPLICATION OF FIRE TESTING AND THEIR OUTPUTS |
BS 5615:1985
|
SPECIFICATION FOR INSULATING JACKETS FOR DOMESTIC HOT WATER STORAGE CYLINDERS |
BS 5262:1991
|
CODE OF PRACTICE FOR EXTERNAL RENDERINGS |
BS 5871-3:2005
|
SPECIFICATION FOR THE INSTALLATION AND MAINTENANCE OF GAS FIRES, CONVECTOR HEATERS, FIRE/BACK BOILERS AND DECORATIVE FUEL EFFECT GAS APPLIANCES - PART 3: DECORATIVE FUEL EFFECT GAS APPLIANCES OF HEAT INPUT NOT EXCEEDING 20 KW (2ND AND 3RD FAMILY GASES) |
BS 5258-1:1986
|
SAFETY OF DOMESTIC GAS APPLIANCES - SPECIFICATION FOR CENTRAL HEATING BOILERS AND CIRCULATORS |
BS 5258-5:1989
|
SAFETY OF DOMESTIC GAS APPLIANCES - SPECIFICATION FOR GAS FIRES |
BS 5871-1:2005
|
SPECIFICATION FOR THE INSTALLATION AND MAINTENANCE OF GAS FIRES, CONVECTOR HEATERS, FIRE/BACK BOILERS AND DECORATIVE FUEL EFFECT GAS APPLIANCES - PART 1: GAS FIRES, CONVECTOR HEATERS, FIRE/BACK BOILERS AND HEATING STOVES (2ND AND 3RD FAMILY GASES) |
BS 7258-1:1994
|
LABORATORY FUME CUPBOARDS - SPECIFICATION FOR SAFETY AND PERFORMANCE |
BS 4508-1:1986
|
Thermally insulated underground pipelines Specification for steel cased systems with air gap |
BS 6266:1992
|
CODE OF PRACTICE FOR FIRE PROTECTION FOR ELECTRONIC DATA PROCESSING INSTALLATIONS |
BS 5990:2006
|
SPECIFICATION FOR DIRECT GAS-FIRED FORCED CONVECTION AIR HEATERS WITH RATED HEAT INPUTS GREATER THAN 330 KW BUT NOT EXCEEDING 2 MW FOR INDUSTRIAL AND COMMERCIAL SPACE HEATING - SAFETY AND PERFORMANCE REQUIREMENTS (EXCLUDING ELECTRICAL REQUIREMENTS) (2ND FAMILY GASES) |
BS 5258-4:1987
|
SAFETY OF DOMESTIC GAS APPLIANCES - SPECIFICATION FOR FANNED CIRCULATION DUCTED AIR HEATERS |
BS 5990:1981
|
SPECIFICATION FOR DIRECT GAS FIRED FORCED CONVECTION AIR HEATERS FOR SPACE HEATING (60 KW UP TO 2 MW INPUT) SAFETY AND PERFORMANCE REQUIREMENTS (EXCLUDING ELECTRICAL REQUIREMENTS) (2ND FAMILY GASES) |
BS 5258-12:1990
|
SAFETY OF DOMESTIC GAS APPLIANCES - SPECIFICATION FOR DECORATIVE FUEL EFFECT GAS APPLIANCES (2ND AND 3RD FAMILY GASES) |
BS 5492:1990
|
CODE OF PRACTICE FOR INTERNAL PLASTERING |
BS 6853:1999
|
CODE OF PRACTICE FOR FIRE PRECAUTIONS IN THE DESIGN AND CONSTRUCTION OF PASSENGER CARRYING TRAINS |
BS 5306-4:2001+A1:2012
|
Fire extinguishing installations and equipment on premises Specification for carbon dioxide systems |
BS 8313:1997
|
Code of practice for accommodation of building services in ducts |
BS 5803-1:1985
|
THERMAL INSULATION FOR USE IN PITCHED ROOF SPACES IN DWELLINGS - SPECIFICATION FOR MAN MADE MINERAL FIBRE THERMAL INSULATION MATS |
BS 8202-2:1992
|
COATINGS FOR FIRE PROTECTION OF BUILDING ELEMENTS - CODE OF PRACTICE FOR THE USE OF INTUMESCENT COATING SYSTEMS TO METALLIC SUBSTRATES FOR PROVIDING FIRE RESISTANCE |
BS 7435-1:1991
|
FIBRE CEMENT FLUE PIPES, FITTINGS AND TERMINALS - SPECIFICATION FOR LIGHT QUALITY FIBRE CEMENT FLUE PIPES, FITTINGS AND TERMINALS |
BS 7346-1:1990
|
COMPONENTS FOR SMOKE AND HEAT CONTROL SYSTEMS - SPECIFICATION FOR NATURAL SMOKE AND HEAT EXHAUST VENTILATORS |
BS 5258-16:1991
|
SAFETY OF DOMESTIC GAS APPLIANCES - SPECIFICATION FOR INSET LIVE FUEL EFFECT GAS FIRES (2ND AND 3RD FAMILY GASES) |
BS 5258-13:1986
|
SAFETY OF DOMESTIC GAS APPLIANCES - SPECIFICATION FOR CONVECTOR HEATERS |
BS 7435-2:1991
|
FIBRE CEMENT FLUE PIPES, FITTINGS AND TERMINALS - SPECIFICATION FOR HEAVY QUALITY FIBRE CEMENT FLUE PIPES, FITTINGS AND TERMINALS |
11/30218915 DC : DRAFT JAN 2011
|
BS 6164 - CODE OF PRACTICE FOR HEALTH AND SAFETY IN TUNNELING IN THE CONSTRUCTION INDUSTRY |
BS 5492:1977
|
CODE OF PRACTICE FOR INTERNAL PLASTERING |
DD ENV 1995-1.2 : DRAFT JAN 2000
|
EUROCODE 5: DESIGN OF TIMBER STRUCTURES - PART 1-2 - GENERAL RULES - STRUCTURAL FIRE DESIGN |
BS 5871-4:2007
|
SPECIFICATION FOR THE INSTALLATION AND MAINTENANCE OF GAS FIRES, CONVECTOR HEATERS, FIRE/BACK BOILERS AND DECORATIVE FUEL EFFECT APPLIANCES - PART 4: INDEPENDENT GAS-FIRED FLUELESS FIRES, CONVECTOR HEATERS AND HEATING STOVES OF NOMINAL HEAT INPUT NOT EXCEEDING 6 KW (2ND AND 3RD FAMILY GASES) |
BS 5978-1:1983
|
SAFETY AND PERFORMANCE OF GAS FIRED HOT WATER BOILERS (60 KW TO 2 MW INPUT) - SPECIFICATION FOR GENERAL REQUIREMENTS |
BS CP334-3(1971) : 1971
|
SELECTION AND INSTALLATION OF TOWN GAS COOKING AND REFRIGERATING APPLIANCES - REFRIGERATORS |
BS 3198:1981
|
Specification for copper hot water storage combination units for domestic purposes |
BS CP335-1(1973) : 1973
|
CODE OF PRACTICE FOR SELECTION AND INSTALLATION OF MISCELLANEOUS TOWN GAS APPLIANCES - DOMESTIC LAUNDERING AND MISCELLANEOUS APPLIANCES |
BS 5258-17:1992
|
SAFETY OF DOMESTIC GAS APPLIANCES - SPECIFICATION FOR DIRECT GAS-FIRED TUMBLE DRYERS (2ND AND 3RD FAMILY GASES) |
ACI 544.1R : 1996
|
REPORT ON FIBER REINFORCED CONCRETE |
PD 7974-3:2003
|
APPLICATION OF FIRE SAFETY ENGINEERING PRINCIPLES TO THE DESIGN OF BUILDINGS - PART 3: STRUCTURAL RESPONSE AND FIRE SPREAD BEYOND THE ENCLOSURE OF ORIGIN (SUB-SYSTEM 3) |
I.S. 260:1984
|
MINERAL FIBRE MATS FOR THERMAL INSULATION OF BUILDINGS |
BS 1703:2005
|
REFUSE CHUTES AND HOPPERS - SPECIFICATION |
BS 8202-1:1987
|
COATINGS FOR FIRE PROTECTION OF BUILDING ELEMENTS - CODE OF PRACTICE FOR THE SELECTION AND INSTALLATION OF SPRAYED MINERAL COATINGS |
BS 6203:1982
|
GUIDE TO FIRE CHARACTERISTICS AND FIRE PERFORMANCE OF EXPANDED POLYSTYRENE (EPS) USED IN BUILDING APPLICATIONS |
BS 6762-2:1991
|
SERVICES FOR LEISURE ACCOMMODATION VEHICLES AND TRANSPORTABLE ACCOMMODATION UNITS - CODE OF PRACTICE FOR THE INSTALLATION OF SOLID FUEL FIRED HEATING IN PARK HOMES AND TRANSPORTABLE ACCOMMODATION UNITS |
BS 6676-1:1986
|
THERMAL INSULATION OF CAVITY WALLS USING MAN-MADE MINERAL FIBRE BATTS (SLABS) |
BS 5258-8:1980
|
SAFETY OF DOMESTIC GAS APPLIANCES - COMBINED APPLIANCES GAS FIRE BACK BOILER |
DEFSTAN 02-802/1(2008) : 2008
|
REQUIREMENTS FOR MINERAL WOOL PRODUCTS FOR ACOUSTIC AND THERMAL INSULATION |
BS 5258-3(1975) : LATEST
|
DRYING CABINETS |
BS 5908:1980
|
CODE OF PRACTICE FOR FIRE PRECAUTIONS IN CHEMICAL PLANT |
BS 5991:1983
|
SPECIFICATION FOR INDIRECT GAS FIRED FORCED CONVECTION AIR HEATERS FOR SPACE HEATING (60 KW UP TO 2 MW INPUT) SAFETY & PERFORMANCE REQUIREMENTS (EXCLUDING ELECTRICAL REQUIREMENTS) 2ND FAMILY GASES |
BS 1566-2:1984
|
Copper indirect cylinders for domestic purposes Specification for single feed indirect cylinders |
BS 5427-1:1996
|
CODE OF PRACTICE FOR THE USE OF PROFILED SHEET FOR ROOF AND WALL CLADDING ON BUILDINGS - DESIGN |
14/30285453 DC : 0
|
BS 5410-1 - CODE OF PRACTICE FOR OIL FIRING - PART 1: INSTALLATIONS UP TO 45 KW OUTPUT CAPACITY FOR SPACE HEATING AND HOT WATER SUPPLY PURPOSES |
BS 5588-5:1986
|
FIRE PRECAUTIONS IN THE DESIGN AND CONSTRUCTION OF BUILDINGS - CODE OF PRACTICE FOR FIREFIGHTING STAIRWAYS AND LIFTS |
PD 6520:1988
|
Guide to fire test methods for building materials and elements of construction |
BS 5306-7:1988
|
FIRE EXTINGUISHING INSTALLATIONS AND EQUIPMENT ON PREMISES - SPECIFICATION FOR POWDER SYSTEMS |
BS 5588-9:1989
|
FIRE PRECAUTIONS IN THE DESIGN AND CONSTRUCTION OF BUILDINGS - CODE OF PRACTICE FOR VENTILATION AND AIR CONDITIONING DUCTWORK |
BS 5258-9:1989
|
Safety of domestic gas appliances Specification for combined appliances: fanned-circulation ducted-air heaters/circulators |
08/30147222 DC : DRAFT JUNE 2008
|
BS 5422 - METHOD FOR SPECIFYING THERMAL INSULATING MATERIALS FOR PIPES, TANKS, VESSELS, DUCTWORK AND EQUIPMENT OPERATING WITHIN THE TEMPERATURE RANGE -40 DEGREE C TO +700 DEGREE C |
BS 5258-15:1990
|
SAFETY OF DOMESTIC GAS APPLIANCES - SPECIFICATION FOR COMBINATION BOILERS |
04/30107486 DC : DRAFT FEB 2004
|
BS 8414-2 - FIRE PERFORMANCE OF EXTERNAL CLADDING SYSTEMS - PART 2: TEST METHOD FOR NON-LOADBEARING CLADDING SYSTEMS FIXED TO AND SUPPORTED BY A STRUCTURAL STEEL FRAME |
BS 5803-2:1985
|
THERMAL INSULATION FOR USE IN PITCHED ROOF SPACES IN DWELLINGS - SPECIFICATION FOR MAN MADE MINERAL FIBRE THERMAL INSULATION IN PELLETED OR GRANULAR FORM FOR APPLICATION BY BLOWING |
09/30166542 DC : 0
|
BS 5546 - SPECIFICATION FOR INSTALLATION AND MAINTENANCE OF GAS-FIRED WATER-HEATING APPLIANCES OF RATED INPUT NOT EXCEEDING 70 KW NET |
BS 4422-9:1990
|
GLOSSARY OF TERMS ASSOCIATED WITH FIRE - MARINE TERMS |
I.S. 140-1:1987
|
SCHOOL FURNITURE - PART 1: TABLES AND CHAIRS FOR SCHOOLS |
BS 6232-1:1982
|
THERMAL INSULATION OF CAVITY WALLS BY FILLING WITH BLOWN MAN MADE MINERAL FIBRE - SPECIFICATION FOR THE PERFORMANCE OF INSTALLATION SYSTEMS |
BS 5588-1:1990
|
FIRE PRECAUTIONS IN THE DESIGN, CONSTRUCTION AND USE OF BUILDINGS - PART 1: CODE OF PRACTICE FOR RESIDENTIAL BUILDINGS |
BS 8313:1989
|
CODE OF PRACTICE FOR ACCOMMODATION OF BUILDING SERVICES IN DUCTS |
BS 5422:1977
|
SPECIFICATION FOR THE USE OF THERMAL INSULATING MATERIALS |
DEFSTAN 07-247(PT1)/3(2009) : 2009
|
THE SELECTION OF MATERIALS ON THE BASIS OF THEIR FIRE CHARACTERISTICS - PART 1: SELECTION OF MATERIALS ON THE BASIS OF THEIR FIRE CHARACTERISTICS |
BS 7261:1990
|
SPECIFICATION FOR SAFETY OF SMALL NON-DOMESTIC FLUELESS SPACE HEATERS BURNING 3RD FAMILY GASES |
BS 5588-3(1983) : 1983
|
FIRE PRECAUTIONS IN THE DESIGN AND CONSTRUCTION OF BUILDINGS - CODE OF PRACTICE FOR OFFICE BUILDINGS |
DEFSTAN 07-247(PT1)/2(2006) : 2006
|
THE SELECTION OF MATERIALS ON THE BASIS OF THEIR FIRE CHARACTERISTICS - PART 1: SELECTION OF MATERIALS ON THE BASIS OF THEIR FIRE CHARACTERISTICS |
BS 5502-23:1990
|
BUILDINGS AND STRUCTURES FOR AGRICULTURE - CODE OF PRACTICE FOR FIRE PRECAUTIONS |
BS 5258-14:1984
|
SAFETY OF DOMESTIC GAS APPLIANCES - SPECIFICATION FOR BARBECUES (3RD FAMILY GAS) |
BS 5234-1:1992
|
PARTITIONS (INCLUDING MATCHING LININGS) - CODE OF PRACTICE FOR DESIGN AND INSTALLATION |
DEFSTAN 02-802/2(2015) : 2015
|
REQUIREMENTS FOR MINERAL WOOL PRODUCTS FOR ACOUSTIC AND THERMAL INSULATION |
BS 7671(2001) : 2001 AMD 14905
|
REQUIREMENTS FOR ELECTRICAL INSTALLATIONS |
BS 476-22:1987
|
Fire tests on building materials and structures Method for determination of the fire resistance of non-loadbearing elements of construction |
BS 5306-6.2:1989
|
FIRE EXTINGUISHING INSTALLATIONS AND EQUIPMENT ON PREMISES - FOAM SYSTEMS - SPECIFICATION FOR MEDIUM AND HIGH EXPANSION FOAM SYSTEMS |
BS 5422:2009
|
Method for specifying thermal insulating materials for pipes, tanks, vessels, ductwork and equipment operating within the temperature range -40°C to +700°C |
BS 5422:1990
|
Method for specifying thermal insulating materials on pipes, ductwork and equipment (in the temperature range -40°C to +700°C) |
BS 5410-1:1997
|
CODE OF PRACTICE FOR OIL FIRING - PART 1: INSTALLATIONS UP TO 45 KW OUTPUT CAPACITY FOR SPACE HEATING AND HOT WATER SUPPLY PURPOSES |
BS 7671(2008) : 2008
|
REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
BS 6164:2001
|
CODE OF PRACTICE FOR SAFETY IN TUNNELLING IN THE CONSTRUCTION INDUSTRY |