We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
  • BS 5482-1(2005) : 2005

    Current The latest, up-to-date edition.
    Add to Watchlist
    This Standard has been added successfully to your Watchlist.
    Please visit My Watchlist to see all standards that you are watching.
    Please log in or to add this standard to your Watchlist.
    We could not add this standard to your Watchlist.
    Please retry or contact support for assistance.
    You need to be logged in to add this standard to your Watchlist.
    Please log in now or create an account to add.
    You already added this Product in the Watchlist.

    CODE OF PRACTICE FOR DOMESTIC BUTANE- AND PROPANE-GAS-BURNING INSTALLATIONS - PART 1: INSTALLATIONS AT PERMANENT DWELLINGS, RESIDENTIAL PARK HOMES AND COMMERCIAL PREMISES, WITH INSTALLATION PIPEWORK SIZES NOT EXCEEDING DN 25 FOR STEEL AND DN 28 FOR CORRUGATED STAINLESS STEEL OR COPPER

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  01-01-2005

    Publisher:  British Standards Institution

    Add to Watchlist

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Committees responsible
    Foreword
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Exchange of information and installation planning
    5 Materials
    6 Valves
    7 Regulators
    8 Joints
    9 Corrosion
    10 Selection of appliances
    11 LPG supply arrangements
    12 Installation
    13 Inspection, testing and user instructions
    Annex A (normative) Gas soundness testing of LPG service pipework,
                          installation pipework, and appliances
    Annex B (informative) Guide for sizing gas supply pipes
    Annex C (informative) Model emergency action notice or leaflet for
                          users of LPG
    Bibliography

    Abstract - (Show below) - (Hide below)

    Provides guidance and recommendations for the installation of liquefied petroleum gas (LPG) supply systems at permanent dwellings, including residential park homes, and small commercial premises, with installation pipework sizes not exceeding DN 25 for steel and DN 28 for corrugated stainless steel or copper.

    General Product Information - (Show below) - (Hide below)

    Committee GSE/31
    Development Note Supersedes BS 5482-1(1994) and 00/716887 DC. Partially supersedes BS 5482-2(1977). (01/2005) Reviewed and confirmed by BSI, September 2010. (08/2010)
    Document Type Standard
    Publisher British Standards Institution
    Status Current
    Superseded By
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    10/30213917 DC : 0 BS 8660-1 - GAS-FIRED MICRO-COGENERATION APPLIANCES OF RATED THERMAL INPUT NOT EXCEEDING 70 KW NET - PART 1: SPECIFICATION FOR SELECTION, INSTALLATION, INSPECTION, COMMISSIONING, SERVICING AND MAINTENANCE OF STIRLING ENGINE MICRO-COGENERATION APPLIANCES
    BS 8499(2017) : 2017 SPECIFICATION FOR DOMESTIC GAS METER BOXES AND METER BRACKET
    BS 6173(2009) : 2009 SPECIFICATION FOR INSTALLATION AND MAINTENANCE OF GAS-FIRED CATERING APPLIANCES FOR USE IN ALL TYPES OF CATERING ESTABLISHMENTS (2ND AND 3RD FAMILY GASES)
    09/30166542 DC : 0 BS 5546 - SPECIFICATION FOR INSTALLATION AND MAINTENANCE OF GAS-FIRED WATER-HEATING APPLIANCES OF RATED INPUT NOT EXCEEDING 70 KW NET
    BS 5546(2010) : 2010 SPECIFICATION FOR INSTALLATION AND MAINTENANCE OF GAS-FIRED WATER-HEATING APPLIANCES OF RATED INPUT NOT EXCEEDING 70 KW NET
    BS 8660-1(2011) : 2011 GAS-FIRED MICRO-COGENERATION APPLIANCES OF RATED THERMAL INPUT NOT EXCEEDING 70 KW NET - PART 1: SPECIFICATION FOR SELECTION, INSTALLATION, INSPECTION, COMMISSIONING, SERVICING AND MAINTENANCE OF STIRLING ENGINE MICRO-COGENERATION APPLIANCES
    14/30258585 DC : 0 BS 7967 - GUIDE FOR THE USE OF ELECTRONIC PORTABLE COMBUSTION GAS ANALYSERS FOR THE MEASUREMENT OF CARBON MONOXIDE IN DWELLINGS AND THE COMBUSTION PERFORMANCE OF DOMESTIC GAS FIRED APPLIANCES
    BS 5871-2(2005) : 2005 SPECIFICATION FOR THE INSTALLATION AND MAINTENANCE OF GAS FIRES, CONVECTOR HEATERS, FIRE/BACK BOILERS AND DECORATIVE FUEL EFFECT GAS APPLIANCES - PART 2: INSET LIVE FUEL EFFECT GAS FIRES OF HEAT INPUT NOT EXCEEDING 15 KW, AND FIRE/BACK BOILERS (2ND AND 3RD FAMILY GASES)
    13/30261683 DC : 0 BS 6798 - SPECIFICATION FOR SELECTION, INSTALLATION, INSPECTION, COMMISSIONING, SERVICING AND MAINTENANCE OF GAS-FIRED BOILERS OF RATED INPUT NOT EXCEEDING 70 KW NET
    10/30204527 DC : 0 BS 6172 - SPECIFICATION FOR INSTALLATION AND MAINTENANCE OF DOMESTIC GAS COOKING APPLIANCES (2ND AND 3RD FAMILY GASES)
    BS 7967-1(2005) : 2005 CARBON MONOXIDE IN DWELLINGS AND THE COMBUSTION PERFORMANCE OF GAS-FIRED APPLIANCES - PART 1: GUIDE FOR IDENTIFYING AND MANAGING SOURCES OF FUMES, SMELLS, SPILLAGE/LEAKAGE OF COMBUSTION PRODUCTS AND CARBON MONOXIDE DETECTOR ACTIVATION
    BS 8499:2009 SPECIFICATION FOR DOMESTIC GAS METER BOXES AND METER BRACKET
    06/30096954 DC : DRAFT APR 2006 BS 5871-4 - SPECIFICATION FOR THE INSTALLATION AND MAINTENANCE OF GAS FIRES, CONVECTOR HEATERS, FIRE/BACK BOILERS AND DECORATIVE FUEL EFFECT GAS APPLIANCES - PART 4: INDEPENDENT GAS-FIRED FLUELESS FIRES, CONVECTOR HEATERS AND HEATING STOVES OF NOMINAL HEAT INPUT NOT EXCEEDING 6 KW (2ND AND 3RD FAMILY GASES)
    BS 6172(2010) : 2010 SPECIFICATION FOR INSTALLATION, SERVICING AND MAINTENANCE OF DOMESTIC GAS COOKING APPLIANCES (2ND AND 3RD FAMILY GASES)
    S.R. 54:2014 CODE OF PRACTICE FOR THE ENERGY EFFICIENT RETROFIT OF DWELLINGS
    BS 5546(2000) : 2000 SPECIFICATION FOR INSTALLATION OF HOT WATER SUPPLIES FOR DOMESTIC PURPOSES, USING GAS-FIRED APPLIANCES OF RATED INPUT NOT EXCEEDING 70 KW
    08/30166539 DC : DRAFT JULY 2008 BS 6798 - SPECIFICATION FOR INSTALLATION AND MAINTENANCE OF GAS-FIRED BOILERS OF RATED INPUT NOT EXCEEDING 70 KW NET
    BS 5871-4(2007) : 2007 SPECIFICATION FOR THE INSTALLATION AND MAINTENANCE OF GAS FIRES, CONVECTOR HEATERS, FIRE/BACK BOILERS AND DECORATIVE FUEL EFFECT APPLIANCES - PART 4: INDEPENDENT GAS-FIRED FLUELESS FIRES, CONVECTOR HEATERS AND HEATING STOVES OF NOMINAL HEAT INPUT NOT EXCEEDING 6 KW (2ND AND 3RD FAMILY GASES)
    14/30270861 DC : 0 BS 4163 - HEALTH AND SAFETY FOR DESIGN AND TECHNOLOGY IN EDUCATIONAL AND SIMILAR ESTABLISHMENTS - CODE OF PRACTICE
    BS 7967-3(2005) : 2005 CARBON MONOXIDE IN DWELLINGS AND THE COMBUSTION PERFORMANCE OF GAS-FIRED APPLIANCES - PART 3: GUIDE FOR RESPONDING TO MEASUREMENTS OBTAINED FROM ELECTRONIC PORTABLE COMBUSTION GAS ANALYSERS
    BS 6798(2014) : 2014 SPECIFICATION FOR SELECTION, INSTALLATION, INSPECTION, COMMISSIONING, SERVICING AND MAINTENANCE OF GAS-FIRED BOILERS OF RATED INPUT NOT EXCEEDING 70 KW NET
    BS 5871-3(2005) : 2005 SPECIFICATION FOR THE INSTALLATION AND MAINTENANCE OF GAS FIRES, CONVECTOR HEATERS, FIRE/BACK BOILERS AND DECORATIVE FUEL EFFECT GAS APPLIANCES - PART 3: DECORATIVE FUEL EFFECT GAS APPLIANCES OF HEAT INPUT NOT EXCEEDING 20 KW (2ND AND 3RD FAMILY GASES)
    BS 7967-2(2005) : 2005 CARBON MONOXIDE IN DWELLINGS AND THE COMBUSTION PERFORMANCE OF GAS-FIRED APPLIANCES - PART 2: GUIDE FOR USING ELECTRONIC PORTABLE COMBUSTION GAS ANALYSERS IN THE MEASUREMENT OF CARBON MONOXIDE AND THE DETERMINATION OF COMBUSTION PERFORMANCE
    BS PAS 2030(2012) : 2012 IMPROVING THE ENERGY EFFICIENCY OF EXISTING BUILDINGS - SPECIFICATION FOR INSTALLATION PROCESS, PROCESS MANAGEMENT AND SERVICE PROVISION
    13/30199128 DC : 0 BS 6891 - SPECIFICATION FOR THE INSTALLATION AND MAINTENANCE OF LOW PRESSURE GAS INSTALLATION PIPEWORK OF UP TO 35 MM (R1[1/4]) IN PREMISES
    09/30205734 DC : 0 BS 5864 - INSTALLATION AND MAINTENANCE OF GAS-FIRED DUCTED AIR HEATERS OF RATED HEAT INPUT NOT EXCEEDING 70 KW NET (2ND AND 3RD FAMILY GASES) - SPECIFICATION
    BS PAS 2030(2017) : 2017 SPECIFICATION FOR THE INSTALLATION OF ENERGY EFFICIENCY MEASURES (EEM) IN EXISTING BUILDINGS
    BS 5871-1(2005) : 2005 SPECIFICATION FOR THE INSTALLATION AND MAINTENANCE OF GAS FIRES, CONVECTOR HEATERS, FIRE/BACK BOILERS AND DECORATIVE FUEL EFFECT GAS APPLIANCES - PART 1: GAS FIRES, CONVECTOR HEATERS, FIRE/BACK BOILERS AND HEATING STOVES (2ND AND 3RD FAMILY GASES)
    BS 6798(2009) : 2009 SPECIFICATION FOR INSTALLATION AND MAINTENANCE OF GAS-FIRED BOILERS OF RATED INPUT NOT EXCEEDING 70 KW NET
    BS 4163(2007) : 2007 HEALTH AND SAFETY FOR DESIGN AND TECHNOLOGY IN SCHOOLS AND SIMILAR ESTABLISHMENTS - CODE OF PRACTICE
    BS 6400-3(2007) : 2007 SPECIFICATION FOR INSTALLATION, EXCHANGE, RELOCATION AND REMOVAL OF GAS METERS WITH A MAXIMUM CAPACITY NOT EXCEEDING 6 M[3]/H - PART 3: LOW AND MEDIUM PRESSURE (3RD FAMILY GASES)
    BS 3632(2005) : 2005 RESIDENTIAL PARK HOMES - SPECIFICATION
    BS 5864(2010) : 2010 INSTALLATION AND MAINTENANCE OF GAS-FIRED DUCTED AIR HEATERS OF RATED HEAT INPUT NOT EXCEEDING 70 KW NET (2ND AND 3RD FAMILY GASES) - SPECIFICATION
    BS 6891(2005) : 2005 INSTALLATION OF LOW PRESSURE GAS PIPEWORK OF UP TO 35 MM (R1[1/4]) IN DOMESTIC PREMISES (2ND FAMILY GAS) - SPECIFICATION
    BS 6173:2009 SPECIFICATION FOR INSTALLATION AND MAINTENANCE OF GAS-FIRED CATERING APPLIANCES FOR USE IN ALL TYPES OF CATERING ESTABLISHMENTS (2ND AND 3RD FAMILY GASES)
    BS 8499:2017 (published 2017-12) Specification for domestic gas meter boxes and meter bracket
    BS 6172(2010) : 2010 SPECIFICATION FOR INSTALLATION, SERVICING AND MAINTENANCE OF DOMESTIC GAS COOKING APPLIANCES (2ND AND 3RD FAMILY GASES)
    BS 5864:2010 INSTALLATION AND MAINTENANCE OF GAS-FIRED DUCTED AIR HEATERS OF RATED HEAT INPUT NOT EXCEEDING 70 KW NET (2ND AND 3RD FAMILY GASES) - SPECIFICATION
    BS 4163:2007 HEALTH AND SAFETY FOR DESIGN AND TECHNOLOGY IN SCHOOLS AND SIMILAR ESTABLISHMENTS - CODE OF PRACTICE
    BS 3632:2005 RESIDENTIAL PARK HOMES - SPECIFICATION

    Standards Referencing This Book - (Show below) - (Hide below)

    BS 3016(1989) : 1989 SPECIFICATION FOR PRESSURE REGULATORS FOR LIQUEFIED PETROLEUM GASES
    BS EN 1949 : 2011 SPECIFICATION FOR THE INSTALLATION OF LPG SYSTEMS FOR HABITATION PURPOSES IN LEISURE ACCOMMODATION VEHICLES AND ACCOMMODATION PURPOSES IN OTHER VEHICLES
    BS 1179-6(1980) : 1980 GLOSSARY OF TERMS USED IN THE GAS INDUSTRY - COMBUSTION AND UTILIZATION INCLUDING INSTALLATION AT CONSUMERS' PREMISES
    BS 6644(1991) : 1991 SPECIFICATION FOR INSTALLATION OF GAS-FIRED HOT WATER BOILERS OF RATED INPUTS BETWEEN 60 kW AND 2 MW (2ND AND 3RD FAMILY GASES)
    BS 6004(2000) : 2000 ELECTRIC CABLES - PVC INSULATED, NON-ARMOURED CABLES FOR VOLTAGES UP TO AND INCLUDING 450/750 V, FOR ELECTRIC POWER, LIGHTING AND INTERNAL WIRING
    BS 5871-2(2001) : 2001 SPECIFICATION FOR THE INSTALLATION OF GAS FIRES, CONVECTOR HEATERS, FIRE/BACK BOILERS AND DECORATIVE EFFECT GAS APPLIANCES - INSET LIVE FUEL EFFECT GAS FIRES OF HEAT INPUT NOT EXCEEDING 20 KW, AND FIRE/BACK BOILERS (2ND AND 3RD FAMILY GASES)
    BS 6172(2004) : 2004 INSTALLATION AND MAINTENANCE OF DOMESTIC GAS COOKING APPLIANCES (2ND AND 3RD FAMILY GASES) - SPECIFICATION
    BS 6956-1(1988) : 1988 JOINTING MATERIALS AND COMPOUNDS - SPECIFICATION FOR CORRUGATED METAL JOINT RINGS
    BS 6400(1997) : 1997 SPECIFICATION FOR INSTALLATION OF DOMESTIC SIZED GAS METERS (2ND AND 3RD FAMILY GASES)
    BS 3974-1(1974) : 1974 SPECIFICATION FOR PIPE SUPPORTS - PIPE HANGERS, SLIDER AND ROLLER TYPE SUPPORTS
    BS 5440-1(2000) : 2000 INSTALLATION AND MAINTENANCE OF FLUES AND VENTILATION FOR GAS APPLIANCES OF RATED INPUT NOT EXCEEDING 70 KW NET (1ST, 2ND AND 3RD FAMILY GASES) - PART 1: SPECIFICATION FOR INSTALLATION AND MAINTENANCE OF FLUES
    BS 5871-3(2001) : 2001 SPECIFICATION FOR THE INSTALLATION OF GAS FIRES, CONVECTOR HEATERS, FIRE/BACK BOILERS AND DECORATIVE EFFECT GAS APPLIANCES - DECORATIVE FUEL EFFECT GAS APPLIANCES OF HEAT INPUT NOT EXCEEDING 20 KW (2ND AND 3RD FAMILY GASES)
    BS 6231(1998) : 1998 SPECIFICATION FOR PVC-INSULATED CABLES FOR SWITCHGEAR AND CONTROLGEAR WIRING
    BS EN 1057 : 2006 COPPER AND COPPER ALLOYS - SEAMLESS, ROUND COPPER TUBES FOR WATER AND GAS IN SANITARY AND HEATING APPLICATIONS
    BS EN 1044 : 1999 BRAZING - FILLER METALS
    BS 21(1985) : 1985 SPECIFICATION FOR PIPE THREADS FOR TUBES AND FITTINGS WHERE PRESSURE-TIGHT JOINTS ARE MADE ON THE THREADS (METRIC DIMENSIONS)
    BS 7786(1995) : 1995 SPECIFICATION FOR UNSINTERED PTFE TAPE - GENERAL REQUIREMENTS
    BS 1710(1984) : 1984 SPECIFICATION FOR IDENTIFICATION OF PIPELINES AND SERVICES
    BS 5292(1980) : 1980 SPECIFICATION FOR JOINTING MATERIALS AND COMPOUNDS FOR INSTALLATIONS USING WATER LOW PRESSURE STEAM OR 1ST, 2ND AND 3RD FAMILY
    BS EN 29453 : 1994 SOFT SOLDER ALLOYS - CHEMICAL COMPOSITIONS AND FORMS
    BS 7281(1990) : 1990 SPECIFICATION FOR POLYETHYLENE PIPES FOR THE SUPPLY OF GASEOUS FUELS
    BS 1494-1(1964) : 1964 SPECIFICATION FOR FIXING ACCESSORIES FOR BUILDING PURPOSES - FIXINGS FOR SHEET, ROOF AND WALL COVERINGS
    BS 7671(2001) : 2001 AMD 14905 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS
    BS 6700(1997) : 1997 SPECIFICATION FOR DESIGN, INSTALLATION, TESTING AND MAINTENANCE OF SERVICES SUPPLYING WATER FOR DOMESTIC USE WITHIN BUILDINGS AND THEIR CARTILAGES
    BS 1723(1963) : PD 6264
    BS 7336(1990) : 1990 SPECIFICATION FOR POLYETHYLENE FUSION FITTINGS WITH INTEGRAL HEATING ELEMENT(S) FOR USE WITH POLYETHYLENE PIPES FOR THE CONVEYANCE OF GASEOUS FUELS
    BS EN 1254-2:1998 COPPER AND COPPER ALLOYS - PLUMBING FITTINGS - FITTINGS WITH COMPRESSION ENDS FOR USE WITH COPPER TUBES
    BS 6173(2001) : 2001 SPECIFICATION FOR INSTALLATION OF GAS-FIRED CATERING APPLIANCES FOR USE IN ALL TYPES OF CATERING ESTABLISHMENTS (2ND AND 3RD FAMILY GASES)
    BS 7838(1996) : 1996 SPECIFICATION FOR CORRUGATED STAINLESS STEEL SEMI-RIGID PIPE AND ASSOCIATED FITTINGS FOR LOW-PRESSURE GAS PIPEWORK OF UP TO DN 50
    BS 5871-1(2001) : 2001 SPECIFICATION FOR THE INSTALLATION OF GAS FIRES, CONVECTOR HEATERS, FIRE/BACK BOILERS AND DECORATIVE EFFECT GAS APPLIANCES - GAS FIRES, CONVECTOR HEATERS, FIRE/BACK BOILERS AND HEATING STOVES (1ST, 2ND, AND 3RD FAMILY GASES)
    BS 5440-2(2000) : 2000 INSTALLATION AND MAINTENANCE OF FLUES AND VENTILATION FOR GAS APPLIANCES OF RATED INPUT NOT EXCEEDING 70 KW NET (1ST, 2ND AND 3RD FAMILY GASES) - PART 2: SPECIFICATION FOR INSTALLATION AND MAINTENANCE OF VENTILATION FOR GAS APPLIANCES
    BS 5449(1990) : 1990 SPECIFICATION FOR FORCED CIRCULATION HOT WATER CENTRAL HEATING SYSTEMS FOR DOMESTIC PREMISES
    BS 5546(2000) : 2000 SPECIFICATION FOR INSTALLATION OF HOT WATER SUPPLIES FOR DOMESTIC PURPOSES, USING GAS-FIRED APPLIANCES OF RATED INPUT NOT EXCEEDING 70 KW
    BS 3605(1973) : 1973 SPECIFICATION FOR SEAMLESS AND WELDED AUSTENITIC STAINLESS STEEL PIPES AND TUBES FOR PRESSURE PURPOSES
    BS EN 837-1 : 1998 PRESSURE GAUGES - PART 1: BOURDON TUBE PRESSURE GAUGES - DIMENSIONS, METROLOGY, REQUIREMENTS AND TESTING
    BS 5114(1975) : 1975 SPECIFICATION FOR PERFORMANCE REQUIREMENTS FOR JOINTS AND COMPRESSION FITTINGS FOR USE WITH POLYETHYLENE PIPES
    BS 1387(1985) : 1985 SPECIFICATION FOR SCREWED AND SOCKETED STEEL TUBES AND TUBULARS AND FOR PLAIN END STEEL TUBES SUITABLE FOR WELDING OR FOR SCREWING TO BS 21 PIPE THREADS
    BS 1552(1995) : 1995 SPECIFICATION FOR OPEN BOTTOMED TAPER PLUG VALVES FOR 1ST, 2ND AND 3RD FAMILY GASES UP TO 200 MBAR
    BS 5864(2004) : 2004 INSTALLATION AND MAINTENANCE OF GAS-FIRED DUCTED AIR HEATERS OF RATED INPUT NOT EXCEEDING 70 KW NET (2ND AND 3RD FAMILY GASES) - SPECIFICATION
    BS 3212(1991) : 1991 SPECIFICATION FOR FLEXIBLE RUBBER TUBING, RUBBER HOSE AND RUBBER HOSE ASSEMBLIES FOR USE IN LPG VAPOUR PHASE AND LPG/AIR INSTALLATIONS
    BS 6956-6(1992) : 1992 JOINTING MATERIALS AND COMPOUNDS - SPECIFICATION FOR JOINTING COMPOUNDS FOR 3RD FAMILY GASES
    BS 1179(1967) : 1967 GLOSSARY OF TERMS USED IN THE GAS INDUSTRY
    BS 6956-7(1992) : 1992 JOINTING MATERIALS AND COMPOUNDS - SPECIFICATION FOR ANAEROBIC JOINTING COMPOUNDS FOR USE WITH 1ST, 2ND AND 3RD FAMILY GASES
    BS 143&1256(2000) : 2000 THREADED PIPE FITTINGS IN MALLEABLE CAST IRON AND CAST COPPER ALLOY
    BS EN 13878:2003 LEISURE ACCOMMODATION VEHICLES - TERMS AND DEFINITIONS
    BS EN 12864 : 2001 LOW-PRESSURE, NON ADJUSTABLE REGULATORS HAVING A MAXIMUM OUTLET PRESSURE OF LESS THAN OR EQUAL TO 200 MBAR, WITH A CAPACITY OF LESS THAN OR EQUAL TO 4 KG/H, AND THEIR ASSOCIATED SAFETY DEVICES FOR BUTANE, PROPANE OR THEIR MIXTURES
    BS EN 331:2015 MANUALLY OPERATED BALL VALVES AND CLOSED BOTTOM TAPER PLUG VALVES FOR GAS INSTALLATIONS FOR BUILDINGS
    BS EN 1254-1:1998 COPPER AND COPPER ALLOYS - PLUMBING FITTINGS - FITTINGS WITH ENDS FOR CAPILLARY SOLDERING OR CAPILLARY BRAZING TO COPPER TUBES
    BS EN 10242:1995 (published 2003-08) Threaded pipe fittings in malleable cast iron
    BS 6956-5(1992) : 1992 JOINTING MATERIALS AND COMPOUNDS - SPECIFICATION FOR JOINTING COMPOUNDS FOR USE WITH WATER, LOW PRESSURE SATURATED STEAM, 1ST FAMILY GASES (EXCLUDING COAL GAS) AND 2ND FAMILY GASES
    BS 4250(1997) : 1997 SPECIFICATION FOR COMMERCIAL BUTANE AND COMMERCIAL PROPANE
    BS 7624(2004) : 2004 INSTALLATION AND MAINTENANCE OF DOMESTIC DIRECT GAS-FIRED TUMBLE DRYERS OF UP TO 6 KW HEAT INPUT (2ND AND 3RD FAMILY GASES) - SPECIFICATION
    BS 6007(2000) : 2000 ELECTRIC CABLES - SINGLE CORE UNSHEATHED HEAT RESISTING CABLES FOR VOLTAGES UP TO AND INCLUDING 450/750 V, FOR INTERNAL WIRING
    BS 3632(1995) : 1995 SPECIFICATION FOR RESIDENTIAL PARK HOMES
    BS 6798(2000) : 2000 SPECIFICATION FOR INSTALLATION OF GAS-FIRED BOILERS OF RATED INPUT NOT EXCEEDING 70 KW NET
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective