BS 5724-3.26:1990

Current

Current

The latest, up-to-date edition.

Medical electrical equipment. Particular requirements for performance Method for declaring parameters for ultrasonic diagnostic equipment using test objects

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

29-06-1990

Foreword
Committees responsible
Method
Section one. General
1. Scope and object
2. Definitions
Section two. Preliminary test and operating conditions
3. Preliminary test and operating conditions
Section three. Declaration and measurement of parameters
4. Performance parameters
5. Resolution
6. DEAD ZONE
7. SLICE THICKNESS
8. DEPTHS OF PENETRATION
9. DISPLAYED DYNAMIC RANGE
10. MAGNIFICATION ERRORS
11. REGISTRATION ERROR
12. ACCURACY OF THE CALLIPER
13. Presentation of performance parameters
Section four. Requirements for TEST-OBJECTS
14. TEST OBJECT design
Appendix
A. Tissue-mimicking material
Table
1. Specified values for the attenuation of sound in
     tissue-mimicking materials
Figures
1. Section through TEST OBJECT CONFIGURATION 1 to
     determine AXIAL RESOLUTION DEAD ZONE and DEPTHS
     OF PENETRATION when 2 MHz2. Section through the REFERENCE PLANE OF TEST OBJECT
     CONFIGURATION 2 to determine LATERAL RESOLUTION
     when 2MHz3. Section in a plane perpendicular to the REFERENCE
     PLANE OF TEST OBJECT CONFIGURATION 3 to determine
     SLICE THICKNESS when 2MHz4. Section through the REFERENCE PLANE OF TEST OBJECT
     CONFIGURATION 4 for the production of an ACOUSTIC
     GREY SCALE wedge when 2MHz5. Section through the REFERENCE PLANE OF TEST OBJECT
     CONFIGURATION 5 to determine MAGNIFICATION ERROR,
     REGISTRATION ERROR and ACCURACY OF THE CALLIPER
     when 2NHz

Covers test methods for the following parameters for the quality of the image: axial resolution, lateral resolution, dead zone distance, slice thickness, depth of penetration, displayed dynamic range, magnification errors, registration error and accuracy of the caliper.

This Section of BS5724 describes the performance parameters to be stated in documents accompanying an ultrasonic medical diagnostic equipment as defined in 2.31, together with methods for evaluating its performance using specified test-objects. This Section of BS5724 does not cover Doppler effect facilities of ultrasonic medical diagnostic equipment.

Committee
CH/62/2
DevelopmentNote
Supersedes 87/52777 DC. (08/2005) Reviewed and confirmed by BSI, December 2011. (11/2011)
DocumentType
Standard
Pages
24
PublisherName
British Standards Institution
Status
Current

View more information
£198.00
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.