ELECTRIC CABLES - CALCULATION OF THE CURRENT RATING - THERMAL RESISTANCE - CALCULATION OF THERMAL RESISTANCE
Superseded date

30-06-2008

Published date

23-11-2012

Committees responsible
National foreword
Introduction
Method
1 General
1.1 Scope
1.2 Symbols
2 Calculation of thermal resistances
2.1 Thermal resistance of the constituent parts of
    a cable, T1, T2 and T3
2.2 External thermal resistance T4
3 Digital calculation of quantities given graphically
3.1 General
3.2 Calculation of dts by means of a diagram
Tables
1 Thermal resistivities of materials
2 Values for constants Z, E and g for black
    surfaces of cables in free air
3 Absorption coefficient of solar radiation for
    cable surfaces
4 Values of constants U, V and Y
Figures
1 Diagram showing a group of q cables and their
    reflection in the ground-air surface
2 Geometric factor G for two-core belted cables with
    circular conductors
3 Geometric factor G for three-core belted cables with
    circular conductors
4 Values of constants, U, V and Y
Figures
1 Diagram showing a group of q cables and their
    reflection in the ground-air surface
2 Geometric factor G for two-core belted cables with
    circular conductors
3 Geometric factor G for three-core belted cables with
    circular conductors
4 Thermal resistance of three-core screened cables
    with circular conductors compared to that of a
    corresponding unscreened cable
5 Thermal resistance of three-core screened cables
    with sector-shaped conductors compared with that
    of a corresponding unscreened cable
6 Geometric factor G for obtaining the thermal
    resistances of the filling material between the
    sheaths and armour of SL and SA type cables
7 Heat dissipation coefficient for black surfaces of
    cables in air
8 Graph for the calculation of external thermal
    resistance of cables in air

Applies to conditions of steady-state operation of cables at all alternating voltages and direct voltages to 5 kV, buried in the ground directly, in troughs or steel pipes, with or without partial drying-out of soil, also in cables in air. Supplies formulae for thermal resistance.

Committee
GEL/20
DevelopmentNote
Also numbered as IEC 60287-2-1 Supersedes 98/264617 DC (08/2002) Reviewed and confirmed by BSI, March 2006. (03/2006) Renumbered & Superseded by BS IEC 60287-2-1. (06/2008)
DocumentType
Standard
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

BS 7769-2.2:1997 Electric cables. Calculation of the current rating. Thermal resistance A method for calculating reduction factors for groups of cables in free air, protected from solar radiation

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.