• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

BS 7870-3.12:2001

Withdrawn
Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

View Superseded by
withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for distribution cables of rated voltage 0.6/1 kV - XLPE insulated combined neutral and earth copper wire concentric cables with copper or aluminium conductors, having low emission of smoke and corrosive gases when affected by fire
Available format(s)

Hardcopy , PDF

Withdrawn date

13-02-2019

Language(s)

English

Published date

04-02-2004

Committees responsible
Foreword
1 Scope
2 Normative references
3 Voltage designation
4 Phase conductors
5 Insulation
6 Assembly of cores
7 Bedding for 3-phase cables
8 Neutral/earth concentric conductor
9 Oversheath
10 Marking
11 End sealing
12 Dimensions
13 Tests
14 Routine tests
15 Sample tests
16 Type tests
Annex A (normative) Test for shrinkage of sheath on
        cable
Bibliography

Specifies requirements for the construction, dimensions and mechanical and electrical properties of concentric copper wire combined neutral/earth (CNE) service cables having a rated voltage of 0.6/1 (1.2) kV. It is applicable to cables that, when assessed by the specified tests, produce lower levels of smoke and corrosive gases under exposure to fire.

Committee
GEL/20/16
DevelopmentNote
To be read in conjunction with BS 7870-1(1996) & BS 7870-2(1999) Supersedes 99/244661 DC & 02/209788 DC (02/2004)
DocumentType
Standard
Pages
16
PublisherName
British Standards Institution
Status
Withdrawn
SupersededBy
Supersedes

Standards Relationship
HD 603 S1:1994/A3:2007 Identical

BS 7870-3.11:2011 LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for distribution cables of rated voltage 0.6/1 kV. XLPE insulated combined neutral and earth copper wire concentric cables with copper or aluminium conductors
BS 7870-3.11:2001 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables of rated voltage 0.6/1 kV XLPE insulated combined neutral and earth copper wire concentric cables with copper or aluminium conductors
11/30214059 DC : 0 BS 7870-3.11 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 3: SPECIFICATION FOR DISTRIBUTION CABLES OF RATED VOLTAGE 0.6/1 KV - SECTION 3.11: XLPE INSULATED COMBINED NEUTRAL AND EARTH COPPER WIRE CONCENTRIC CABLES WITH COPPER OR ALUMINIUM CONDUCTORS
BS 7870-3.10:2001 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables of rated voltage 0.6/1 kV PVC insulated combined neutral and earth copper wire concentric cables with copper or aluminium conductors

HD 622 S1:1996/A2:2005 Power cables having rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV with special fire performance for use in power stations
HD 627 S1:1996/A2:2005 MULTICORE AND MULTIPAIR CABLES FOR INSTALLATION ABOVE AND BELOW GROUND
BS EN 50268-2:2000 Common test methods for cables under fire conditions. Measurement of smoke density of cables burning under defined conditions Procedure
BS EN 50268-1:2000 Common test methods for cables under fire conditions. Measurement of smoke density of cables burning under defined conditions Apparatus
HD 605 S2:2008/corrigendum:2010 ELECTRIC CABLES - ADDITIONAL TEST METHODS
HD 620 : 2010 DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV
BS EN 50267-2-1:1999 Common test methods for cables under fire conditions. Tests on gases evolved during combustion of materials from cables. Procedures Determination of the amount of halogen acid gas - Determination of the amount of halogen acid gas
BS EN 60811-1-3:1995 Insulating and sheathing materials of electric cables. Common test methods. General application Methods for determining the density. Water absorption tests. Shrinkage test
HD 626 S1:1996/A2:2002 OVERHEAD DISTRIBUTION CABLES OF RATED VOLTAGE U[O]/U(U[M]): 0,6/1 (1,2) KV
HD 308 S2:2001 Identification of cores in cables and flexible cords
BS EN 50265-2-1:1999 Common test methods for cables under fire conditions. Test for resistance to vertical flame propagation for a single insulated conductor or cable. Procedures 1 kW pre-mixed flame - 1 kW pre-mixed flame
BS 7870-3.10:2001 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables of rated voltage 0.6/1 kV PVC insulated combined neutral and earth copper wire concentric cables with copper or aluminium conductors
BS EN 60811-1-2:1995 Insulating and sheathing materials of electric cables. Common test methods. General application Thermal ageing methods
BS EN 50266-2-4:2001 Common test methods for cables under fire conditions. Test for vertical flame spread of vertically-mounted bunched wires or cables. Procedures Category C
HD 604 S1:1994/A3:2005 0.6/1 KV POWER CABLES WITH SPECIAL FIRE PERFORMANCE FOR USE IN POWER STATIONS

View more information
£134.00
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.