1 Scope
2 Normative references
3 Terms and definitions
4 The principle of the technique
5 Requirements for apparatus and gases
6 Measurement procedure
Annex A (normative) - Determination of the performance
        characteristics of a FID
Annex B (informative) - Basic functionality of an FID
Annex C (informative) - Measurement uncertainty and
        associated statistics
Annex D (informative) - Safety measures
Annex E (informative) - Significant technical changes
Bibliography

Describes the requirements for an instrument using flame ionisation detection, together with procedures for its operation.

This European Standard specifies a flame ionisation detector (FID) method. It is intended for use as a standard reference method for the measurement of the mass concentration of gaseous and vaporous organic substances (expressed as TVOC) in stationary source emissions (e.g. emissions from waste incinerators and solvent using processes, emission measurements according to 2010/75/EU) in the concentration range up to 1000mg/m³.

This European Standard specifies the requirements for an instrument using flame ionisation detection, together with procedures for its operation. The results obtained using this standard are expressed in milligrams per cubic metre (mg/m³) as total carbon (TVOC).

This European Standard is not applicable for permanently installed automated measuring systems (AMS).

Alternative methods to this method may be used provided that the user can demonstrate equivalence, based on the principles of CEN/TS 14793.

Committee
EH/2/1
DevelopmentNote
Supersedes 96/563986 DC. (08/2005) Supersedes BS EN 13526 & 11/30238654 DC. (02/2013)
DocumentType
Standard
Pages
26
PublisherName
British Standards Institution
Status
Current
Supersedes

Standards Relationship
NF EN 12619 : 2013 Identical
NEN EN 12619 : 2013 Identical
I.S. EN 12619:2013 Identical
UNI EN 12619 : 2013 Identical
SN EN 12619 : 2013 Identical
DIN EN 12619:2013-04 Identical
EN 12619:2013 Identical
UNE-EN 12619:2013 Identical
NS EN 12619 : 2013 Identical
NBN EN 12619 : 2013 Identical

ISO 5725-1:1994 Accuracy (trueness and precision) of measurement methods and results — Part 1: General principles and definitions
EN 15267-3:2007 Air quality - Certification of automated measuring systems - Part 3: Performance criteria and test procedures for automated measuring systems for monitoring emissions from stationary sources
CEN/TS 14793:2005 Stationary source emission - Intralaboratory validation procedure for an alternative method compared to a reference method
ISO 14956:2002 Air quality Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty
EN ISO 9169:2006 Air quality - Definition and determination of performance characteristics of an automatic measuring system (ISO 9169:2006)
EN 15267-2:2009 Air quality - Certification of automated measuring systems - Part 2: Initial assessment of the AMS manufacturer’s quality management system and post certification surveillance for the manufacturing process
EN 14789:2017 Stationary source emissions - Determination of volume concentration of oxygen - Standard reference method: Paramagnetism
EN 15259:2007 Air quality - Measurement of stationary source emissions - Requirements for measurement sections and sites and for the measurement objective, plan and report
EN 14181:2014 Stationary source emissions - Quality assurance of automated measuring systems
EN ISO 14956 : 2002 AIR QUALITY - EVALUATION OF THE SUITABILITY OF A MEASUREMENT PROCEDURE BY COMPARISON WITH A REQUIRED MEASUREMENT UNCERTAINTY
ENV 13005 : DRAFT 1999 GUIDE TO THE EXPRESSION OF UNCERTAINTY IN MEASUREMENT
EN 14790:2017 Stationary source emissions - Determination of the water vapour in ducts - Standard reference method
EN 15267-1:2009 Air quality - Certification of automated measuring systems - Part 1: General principles
ISO 9169:2006 Air quality Definition and determination of performance characteristics of an automatic measuring system

View more information
£198.00
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.