BS EN 13126-6:2008

Withdrawn
Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

View Superseded by
withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Building hardware. Requirements and test methods for windows and doors height windows Variable geometry stay hinges (with or without a friction stay)
Available format(s)

Hardcopy , PDF

Withdrawn date

08-09-2018

Language(s)

English

Published date

31-03-2009

Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Classification
  4.1 General
  4.2 Category of use (1 - first digit)
  4.3 Durability (2 - second digit)
  4.4 Mass (3 - third digit)
  4.5 Fire resistance (4 - fourth digit)
  4.6 Safety in use (5 - fifth digit)
  4.7 Corrosion resistance (6 - sixth digit)
  4.8 Security (7 - seventh digit)
  4.9 Application (8 - eighth digit)
  4.10 Test sizes - size limitations (9 - ninth digit)
  4.11 Example of classification for variable geometry stay
       hinges (with or without a friction system - EN 13126-6)
5 Requirements
  5.1 General
  5.2 Integrated restrictors
  5.3 Additional requirements
       5.3.1 Pull-in and pull-in abuse test
       5.3.2 Friction test (where applicable)
       5.3.3 Obstructed track test
       5.3.4 Ease of sash movement test
       5.3.5 Durability test
       5.3.6 Durability pull-in test
       5.3.7 Simulated negative pressure test
       5.3.8 Static load test
       5.3.9 Additional load test
6 Test apparatus
  6.1 General
  6.2 Assembly
       6.2.1 General
       6.2.2 Fixing
  6.3 Additional equipment
       6.3.1 Block for pull-in abuse test
       6.3.2 Steel cross for simulated negative pressure test
7 Test methods
  7.1 Samples
  7.2 Pull-in test
       7.2.1 General
       7.2.2 Pull-in test procedure
  7.3 Friction test
       7.3.1 General
       7.3.2 Friction test procedure
  7.4 Obstructed track test procedure
  7.5 Pull-in abuse test
  7.6 Ease of sash movement test procedure
  7.7 Durability test
       7.7.1 General
       7.7.2 Durability pull-in test procedure
  7.8 Simulated negative pressure test
  7.9 Static load test procedure
  7.10 Additional load test procedure
  7.11 Corrosion resistance
Annex A (normative) - Types of variable geometry stay hinges
        (with or without a friction system)
Annex B (informative) - Test method diagrams
Annex C (normative) - Flow chart of test procedures

Describes requirements and test methods for durability, strength, security and function of mechanically operated variable geometry stay hinges (with or without a friction system).

Committee
B/538/4
DevelopmentNote
Supersedes DD CEN/TS 13126-6. (03/2009)
DocumentType
Standard
Pages
28
PublisherName
British Standards Institution
Status
Withdrawn
SupersededBy
Supersedes

Standards Relationship
EN 13126-6:2008 Identical

EN 1670:2007/AC:2008 BUILDING HARDWARE - CORROSION RESISTANCE - REQUIREMENTS AND TEST METHODS
EN 12519:2004 Windows and pedestrian doors - Terminology
CEN/TS 13126-5:2004 Building hardware, fittings for windows and door height windows - Requirements and test methods - Part 5: Devices that restrict the opening of windows
ISO 4520:1981 Chromate conversion coatings on electroplated zinc and cadmium coatings
EN 13126-1:2011 Building hardware - Hardware for windows and door height windows - Requirements and test methods - Part 1: Requirements common to all types of hardware

View more information
£198.00
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.