We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
  • BS EN 50525-2-21:2011

    Current The latest, up-to-date edition.
    Add to Watchlist
    This Standard has been added successfully to your Watchlist.
    Please visit My Watchlist to see all standards that you are watching.
    Please log in or to add this standard to your Watchlist.
    We could not add this standard to your Watchlist.
    Please retry or contact support for assistance.
    You need to be logged in to add this standard to your Watchlist.
    Please log in now or create an account to add.
    You already added this Product in the Watchlist.

    Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. Flexible cables with crosslinked elastomeric insulation

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  30-09-2011

    Publisher:  British Standards Institution

    Add to Watchlist

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 Scope
    2 Normative references
    3 Terms and definitions
    4 General purpose cables
    5 Water resistant cables
    6 Heat resistant cables (90 degree C)
    7 Heat resistant cables - TPU sheathed
      (90 degree C)
    8 Heat resistant EVA cables (110 degree C) -
      Ordinary duty cables - H05GG-F and H05GGH2-F
    Annex A (normative) - Tests for cables to EN 50525-2-21
    Annex B (normative) - General data
    Annex C (normative) - Requirements for compatibility
            test
    Annex D (normative) - Water resistance test for
            H07RN8-F flexible cables - Electrical test
    Annex E (normative) - Water resistance test for
            H07RN8-F flexible cables - Mechanical properties
            of sheath after water immersion
    Annex F (normative) - Special national conditions
    National Annex (informative) - Origins and identification
                   of the particular cable types
    Bibliography

    Abstract - (Show below) - (Hide below)

    Pertains to flexible cables, insulated with crosslinked elastomeric compound, and sheathed with either crosslinked elastomeric compound or thermoplastic polyurethane (TPU).

    Scope - (Show below) - (Hide below)

    EN50525-2-21 applies to flexible cables, insulated with crosslinked elastomeric compound, and sheathed with either crosslinked elastomeric compound or thermoplastic polyurethane (TPU).

    The cables are of rated voltages U0/U up to and including 450/750V.

    The cables are intended for a variety of applications where appliances or equipment, including heavy industrial equipment, require a flexible connection to the power supply.

    The maximum conductor operating temperatures for the cables in this standard are 60°C (R types), 90°C (B types) and 110°C (G types).

    The following particular cable types are included:

    • General purpose cables (RR and RN types);

    • Water-resistant cables (RN8 types);

    • General purpose cables (BB and BN4 types);

    • TPU sheathed cables (BQ types);

    • Heat resistant cables (GG types)

    NOTE HD 516 contains extensive guidance on the safe use of cables in this standard.

    This EN50525-2-21 should be read in conjunction with EN50525-1, which specifies general requirements.

    General Product Information - (Show below) - (Hide below)

    Committee GEL/20/17
    Development Note Together with BS EN 50525-1, 2-11, 2-12 & 2-71, supersedes BS 6500(2000). Together with BS EN 50525-1, 2-11, 2-51, 2-83 & 3-21, supersedes BS 7919(2001). To be read in conjunction with BS EN 50525-1. Supersedes 08/30188783 DC. (10/2011)
    Document Type Standard
    Publisher British Standards Institution
    Status Current
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    BS 7671(2008) : 2018 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS
    BS 1363-1:2016+A1:2018 13 A plugs, socket-outlets, adaptors and connection units Specification for rewirable and non-rewirable 13 A fused plugs
    15/30297234 DC : 0 BS 1363-2 - 13 A PLUGS, SOCKET-OUTLETS, ADAPTORS AND CONNECTION UNITS - PART 2: SPECIFICATION FOR 13 A SWITCHED AND UNSWITCHED SOCKET-OUTLETS
    15/30297238 DC : 0 BS 1363-4 - 13 A PLUGS, SOCKET-OUTLETS, ADAPTORS AND CONNECTION UNITS - PART 4: SPECIFICATION FOR 13 A FUSED CONNECTION UNITS SWITCHED AND UNSWITCHED
    15/30297236 DC : 0 BS 1363-3 - 13 A PLUGS, SOCKET-OUTLETS, ADAPTORS AND CONNECTION UNITS - PART 3: SPECIFICATION FOR ADAPTORS
    15/30297232 DC : 0 BS 1363-1 - 13 A PLUGS, SOCKET-OUTLETS, ADAPTORS AND CONNECTION UNITS - PART 1: SPECIFICATION FOR REWIRABLE AND NON-REWIRABLE 13 A FUSED PLUGS
    BS 7671(2008) : 2008 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 60719:1993 Calculation of the lower and upper limits for the average outer dimensions of cables with circular copper conductors and of rated voltages up to and including 450/750 V
    EN 50363-10-2 : 2005 Insulating, sheathing and covering materials for low voltage energy cables - Part 10-2: Miscellaneous sheathing compounds - Thermoplastic polyurethane
    IEC 60228:2004 Conductors of insulated cables
    IEC 60502-1:2004+AMD1:2009 CSV Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV(Um = 36 kV) - Part 1: Cables for rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV)
    EN 60228:2005 COR 2005 CONDUCTORS OF INSULATED CABLES
    EN 60332-1-2:2004/A11:2016 TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-2: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR 1 KW PRE-MIXED FLAME (IEC 60332-1-2:2004/A1:2015)
    IEC 60332-1-2:2004+AMD1:2015 CSV Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame
    IEC 60719:1992 Calculation of the lower and upper limits for the average outer dimensions of cables with circular copper conductors and of rated voltages up to and including 450/750 V
    EN 50525-1:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 1: General requirements
    IEC 60811-1-2:1985 Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Two: Thermal ageing methods
    EN 60811-1-2:1995/A2:2000 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - GENERAL APPLICATION - THERMAL AGEING METHODS
    HD 516 S2:1997/A2:2008 GUIDE TO USE OF LOW VOLTAGE HARMONIZED CABLES
    IEC 60811-1-1:1993+AMD1:2001 CSV Common test methods for insulating and sheathing materials of electric cables and optical cables - Part 1-1: Methods for general application - Measurement of thickness and overall dimensions - Tests for determining the mechanical properties
    EN 50395 : 2005 AMD 1 2011 ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES
    EN 50363-1:2005 Insulating, sheathing and covering materials for low voltage energy cables - Part 1: Cross-linked elastomeric insulating compounds
    IEC 60811-1-4:1985 Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Four: Tests at low temperature
    EN 50334:2001 Marking by inscription for the identification of cores of electric cables
    EN 50363-2-1 : 2005 AMD 1 2011 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 2-1: CROSS-LINKED ELASTOMERIC SHEATHING COMPOUNDS
    EN 50396 : 2005 AMD 1 2011 NON ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES
    EN 60811-1-1:1995/A1:2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - GENERAL APPLICATION - MEASUREMENT OF THICKNESS AND OVERALL DIMENSIONS - TESTS FOR DETERMINING MECHANICAL PROPERTIES
    EN 60811-1-4:1995/A2:2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1-4: GENERAL APPLICATION - TESTS AT LOW TEMPERATURE
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective