BS EN 54-12:2015

Current
Current

The latest, up-to-date edition.

Fire detection and fire alarm systems Smoke detectors. Line detectors using an optical beam
Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

30-04-2015

Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
5 Testing, assessment and sampling methods
6 Assessment and verification of constancy of
  performance (AVCP)
7 Classification and designation
8 Marking, labelling and packaging
Annex A (normative) - Bench for response value measurements
Annex B (normative) - Fire test room
Annex C (normative) - Smouldering (pyrolysis) wood fire (TF2)
Annex D (normative) - Glowing smouldering cotton fire (TF3)
Annex E (normative) - Flaming plastics (polyurethane) fire (TF4)
Annex F (normative) - Flaming liquid (n-heptane) fire (TF5)
Annex G (normative) - Apparatus for stray light
Annex H (informative) - Information concerning the requirements
        for the response to slowly developing fires
Annex I (informative) - Data supplied with line detectors using
        an optical beam
Annex ZA (informative) - Clauses of this European Standard addressing
         the provisions of the EU Construction Products
         Regulation
Bibliography

Defines requirements, test methods and performance criteria for line detectors using an optical beam that detect smoke by utilizing the attenuation and/or changes in attenuation of an optical beam, for use in fire detection and fire alarm systems installed in buildings.

This European Standard specifies requirements, test methods and performance criteria for line detectors using an optical beam that detect smoke by utilizing the attenuation and/or changes in attenuation of an optical beam, for use in fire detection and fire alarm systems installed in buildings (see EN54‑1:2011 ). This European Standard provides for the assessment and verification of constancy of performance (AVCP) of line detectors using an optical beam to this EN. This European Standard does not cover: line detectors using an optical beam designed to operate with separations between opposed components of less than 1m; line detectors using an optical beam whose optical path length is defined or adjusted by an integral mechanical connection; line detectors using an optical beam with special characteristics, which cannot be assessed by the test methods in this European Standard. NOTE The term “optical?? is used to describe that part of the electromagnetic spectrum produced by the transmitter to which the receiver is responsive; this is not restricted to visible wavelengths.

Committee
FSH/12/2
DevelopmentNote
Supersedes 91/48810 DC. (08/2003) Supersedes 09/30170243 DC. (04/2015)
DocumentType
Standard
Pages
76
PublisherName
British Standards Institution
Status
Current
Supersedes

Standards Relationship
SN EN 54-12:2015 Identical
ONORM EN 54-12 : 2015 Identical
NF EN 54-12 : 2015 Identical
EN 54-12:2015 Identical
UNI EN 54-12 : 2003 Identical
DIN EN 54-12:2015-10 Identical
NEN EN 54-12 : 2015 Identical
NBN EN 54-12 : 2015 Identical
UNE-EN 54-12:2003 Identical
NS EN 54-12 : 2002 Identical
I.S. EN 54-12:2015 Identical
DIN EN 54-12 E : 2015 Identical

12/30260280 DC : 0 BS 5839-6 - FIRE DETECTION AND FIRE ALARM SYSTEMS FOR BUILDINGS - PART 6: CODE OF PRACTICE FOR THE DESIGN, INSTALLATION, COMMISSIONING AND MAINTENANCE OF FIRE DETECTION AND FIRE ALARM SYSTEMS IN DOMESTIC PREMISES
03/119007 DC : DRAFT DEC 2003 BS 5839-6 - FIRE DETECTION AND FIRE ALARM SYSTEMS FOR BUILDINGS - PART 6: CODE OF PRACTICE FOR THE DESIGN, INSTALLATION AND MAINTENANCE OF FIRE DETECTION AND FIRE ALARM SYSTEMS IN DWELLINGS
BS 5839-6:2013 Fire detection and fire alarm systems for buildings Code of practice for the design, installation, commissioning and maintenance of fire detection and fire alarm systems in domestic premises
BS 5839-1(2002) : 2002 FIRE DETECTION AND FIRE ALARM SYSTEMS FOR BUILDINGS - PART 1: CODE OF PRACTICE FOR SYSTEM DESIGN, INSTALLATION, COMMISSIONING AND MAINTENANCE
BS 5839-1:2017 Fire detection and fire alarm systems for buildings Code of practice for design, installation, commissioning and maintenance of systems in non-domestic premises
BS 5908-2:2012 Fire and explosion precautions at premises handling flammable gases, liquids and dusts Guide to applicable standards and regulations
12/30260278 DC : 0 BS 5839-1 - FIRE DETECTION AND FIRE ALARM SYSTEMS FOR BUILDINGS - PART 1: CODE OF PRACTICE FOR DESIGN, INSTALLATION, COMMISSIONING AND MAINTENANCE
12/30258581 DC : 0 BS 5908-2 - FIRE AND EXPLOSION PRECAUTIONS AT PREMISES HANDLING FLAMMABLE GASES, LIQUIDS AND DUSTS - PART 2: GUIDE TO APPLICABLE STANDARDS AND REGULATIONS
BS 5839-1:2013 Fire detection and fire alarm systems for buildings Code of practice for design, installation, commissioning and maintenance of systems in non-domestic premises
BS 5839-6:2004 Fire detection and fire alarm systems for buildings Code of practice for the design, installation and maintenance of fire detection and fire alarm systems in dwellings

93/68/EEC : 1993 AMD 2 1998 COUNCIL DIRECTIVE 93/68/EEC OF 22.7.93 AMENDING DIRECTIVES 87/404/EEC, 88/378/EEC, 89/106/EEC, 89/336/EEC, 89/392/EEC, 89/686/EEC, 90/384/EEC, 90/385/EEC, 90/396/EEC, 91/263/EEC, 92/42/EEC AND 73/23/EEC
EN 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
EN 60068-2-42:2003 Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections
EN 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
EN 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
305/2011 : 2011 AMD 2 2014 REGULATION (EU) NO 305/2011 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 9 MARCH 2011 LAYING DOWN HARMONISED CONDITIONS FOR THE MARKETING OF CONSTRUCTION PRODUCTS AND REPEALING COUNCIL DIRECTIVE 89/106/EEC (TEXT WITH EEA RELEVANCE)
EN 60068-1:2014 Environmental testing - Part 1: General and guidance
EN 54-7:2000/A2:2006 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 7: SMOKE DETECTORS - POINT DETECTORS USING SCATTERED LIGHT, TRANSMITTED LIGHT OR IONIZATION
IEC 60064:1993+AMD1:2000+AMD2:2002+AMD3:2005 CSV Tungsten filament lamps for domestic and similar general lighting purposes - Performance requirements
EN 60064:1995/A5:2009 TUNGSTEN FILAMENT LAMPS FOR DOMESTIC AND SIMILAR GENERAL LIGHTING PURPOSES - PERFORMANCE REQUIREMENTS
EN ISO 9001:2015 Quality management systems - Requirements (ISO 9001:2015)
IEC 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
ISO 9001:2015 Quality management systems — Requirements
IEC 60068-2-42:2003 Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections
EN 60068-2-78:2013 Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
EN 60068-2-6:2008 Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
IEC 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
EN 50130-4:2011/A1:2014 ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS
EN 54-1:2011 Fire detection and fire alarm systems - Part 1: Introduction

View more information
£298.00
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.