• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

BS EN 60079-10-1:2015

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Explosive atmospheres Classification of areas. Explosive gas atmospheres

Available format(s)

Hardcopy , PDF

Superseded date

18-05-2022

Language(s)

English

Published date

31-12-2016

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 General
5 Area classification methodology
6 Release of flammable substance
7 Type of zone
8 Extent of zone
9 Documentation
Annex A (informative) - Suggested presentation of
        hazardous areas
Annex B (informative) - Estimation of sources of release
Annex C (informative) - Ventilation guidance
Annex D (informative) - Estimation of hazardous zones
Annex E (informative) - Examples of hazardous area
        classification
Annex F (informative) - Schematic approach to classification
        of hazardous areas
Annex G (informative) - Flammable mists
Annex H (informative) - Hydrogen
Annex I (informative) - Hybrid mixtures
Annex J (informative) - Useful equations in support to
        hazardous area classification
Annex K (informative) - Industry codes and national
        standards
Bibliography
Annex ZA (normative) - Normative references to
         international publications with their
         corresponding European publications

Gives the classification of areas where flammable gas or vapour hazards may arise and may then be used as a basis to support the proper selection and installation of equipment for use in hazardous areas.

his part of IEC 60079 is concerned with the classification of areas where flammable gas or vapour hazards may arise and may then be used as a basis to support the proper selection and installation of equipment for use in hazardous areas. It is intended to be applied where there may be an ignition hazard due to the presence of flammable gas or vapour, mixed with air, but it does not apply to: mines susceptible to firedamp; the processing and manufacture of explosives; catastrophic failures or rare malfunctions which are beyond the concept of abnormality dealt with in this standard (see 3.7.3 and 3.7.4); rooms used for medical purposes; commercial and industrial applications where only low pressure fuel gas is used for appliances e.g. for cooking, water heating and similar uses, where the installation is compliant with relevant gas codes; domestic premises; where a hazard may arise due to the presence of combustible dusts or combustible flyings but the principles may be used in assessment of a hybrid mixture (refer also IEC 60079-10-2). NOTE Additional guidance on hybrid mixtures is provided in Annex I. Flammable mists may form or be present at the same time as flammable vapour. In such case the strict application of the details in this standard may not be appropriate. Flammable mists may also form when liquids not considered to be a hazard due to the high flash point are released under pressure. In these cases the classifications and details given in this standard do not apply. Information on flammable mists is provided in Annex G. For the purpose of this standard, an area is a three-dimensional region or space. Atmospheric conditions include variations above and below reference levels of 101,3 kPa (1 013 mbar) and 20 °C (293 K), provided that the variations have a negligible effect on the explosion properties of the flammable substances. In any process plant, irrespective of size, there may be numerous sources of ignition apart from those associated with equipment. Appropriate precautions will be necessary to ensure safety in this context. This standard is applicable with judgement for other ignition sources. This standard does not take into account the consequences of ignition of an explosive atmosphere.

Committee
EXL/31/3
DevelopmentNote
Supersedes BS EN 60079-10 & 06/30153066 DC. (04/2009) Supersedes 14/30267617 DC. (03/2016)
DocumentType
Standard
Pages
116
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
IEC 60079-10-1:2015/COR1:2015 Identical
IEC 60079-10-1:2015 Identical
EN 60079-10-1:2015 Identical

BS 7671(2008) : 2018 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS
BS 6164:2011 Code of practice for health and safety in tunnelling in the construction industry
BS 6400-1:2016 Specification for installation, exchange, relocation, maintenance and removal of gas meters with a maximum capacity not exceeding 6 m<sup>3</sup>/h Low pressure (2nd family gases)
DEFSTAN 02-357(PT1)/2(2009) : 2009 REQUIREMENTS FOR GASEOUS FIREFIGHTING SYSTEMS FOR MAIN AND AUXILIARY MACHINERY SPACES ON SURFACE SHIPS - PART 1: GENERAL REQUIREMENTS FOR CARBON DIOXIDE SYSTEMS
DEFSTAN 02-357(PT4)/1(2010) : 2010 REQUIREMENTS FOR GASEOUS FIREFIGHTING SYSTEMS FOR MAIN AND AUXILIARY MACHINERY SPACES ON SURFACE SHIPS - PART 4: GENERAL REQUIREMENTS FOR INERT GAS SYSTEMS INCLUDING ELECTRIC/ELECTRONIC SPACES
12/30258581 DC : 0 BS 5908-2 - FIRE AND EXPLOSION PRECAUTIONS AT PREMISES HANDLING FLAMMABLE GASES, LIQUIDS AND DUSTS - PART 2: GUIDE TO APPLICABLE STANDARDS AND REGULATIONS
14/30286897 DC : 0 PD 8010-1 - PIPELINE SYSTEMS - PART 1: STEEL PIPELINES ON LAND - CODE OF PRACTICE
BS 6896:2011 Specification for installation and maintenance of gas-fired overhead radiant heaters for industrial and commercial heating (2nd and 3rd family gases)
BS 6349-4:2014 Maritime works Code of practice for design of fendering and mooring systems
BS PD8010-1(2015) : 2015 PIPELINE SYSTEMS - PART 1: STEEL PIPELINES ON LAND - CODE OF PRACTICE
BS 6644:2011 Specification for the installation and maintenance of gas-fired hot water boilers of rated inputs between 70 kW (net) and 1.8 MW (net) (2nd and 3rd family gases)
BS 6230:2011 Specification for installation of gas-fired forced convection air heaters for commercial and industrial space heating (2nd and 3rd family gases)
BS 5908-2:2012 Fire and explosion precautions at premises handling flammable gases, liquids and dusts Guide to applicable standards and regulations
11/30218915 DC : DRAFT JAN 2011 BS 6164 - CODE OF PRACTICE FOR HEALTH AND SAFETY IN TUNNELING IN THE CONSTRUCTION INDUSTRY
11/30229803 DC : 0 BS 6230 - SPECIFICATION FOR INSTALLATION OF GAS-FIRED FORCED CONVECTION AIR HEATERS FOR COMMERCIAL AND INDUSTRIAL SPACE HEATING (2ND AND 3RD FAMILY GASES)
BS 5908-1:2012 Fire and explosion precautions at premises handling flammable gases, liquids and dusts Code of practice for precautions against fire and explosion in chemical plants, chemical storage and similar premises
14/30281818 DC : 0 BS 6400-1 - SPECIFICATION FOR INSTALLATION, EXCHANGE, RELOCATION, MAINTENANCE AND REMOVAL OF GAS METERS WITH A MAXIMUM CAPACITY NOT EXCEEDING 6 M[3]/H - PART 1: LOW PRESSURE (2ND FAMILY GASES)
BS 7671(2008) : 2008 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS

BS 5925:1991 Code of practice for ventilation principles and designing for natural ventilation
EN 1127-1:2011 Explosive atmospheres - Explosion prevention and protection - Part 1: Basic concepts and methodology
EN 60079-0:2012/A11:2013 EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS (IEC 60079-0:2011, MODIFIED)
CEI 31-35 : 2012 EXPLOSIVE ATMOSPHERES - GUIDE FOR CLASSIFICATION OF HAZARDOUS AREAS FOR THE PRESENCE OF GAS IN APPLICATION OF CEI EN 60079-10-1 (CEI 31-87)
EN 60079-10-2:2015 Explosive atmospheres - Part 10-2: Classification of areas - Explosive dust atmospheres
IEC 60079-20-1:2010 Explosive atmospheres - Part 20-1: Material characteristics for gas and vapour classification - Test methods and data
IEC 60079-0:2011 Explosive atmospheres - Part 0: Equipment - General requirements
IEC 60079-14:2013 Explosive atmospheres - Part 14: Electrical installations design, selection and erection
EN 60079-20-1:2010 Explosive atmospheres - Part 20-1: Material characteristics for gas and vapour classification - Test methods and data
EN 60079-14:2014/AC:2016 EXPLOSIVE ATMOSPHERES - PART 14: ELECTRICAL INSTALLATIONS DESIGN, SELECTION AND ERECTION (IEC 60079-14:2013/COR1:2016)
IEC 61285:2015 Industrial-process control - Safety of analyser houses
EN 61285:2015 Industrial-process control - Safety of analyzer houses

View more information
£298.00
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.