INTRODUCTION
1 Scope and object
2 Normative references
3 Terms and definitions
4 Clearances
  4.1 General conditions
  4.2 Basic information
  4.3 Homogeneous and approximately homogeneous fields
      4.3.1 Conditions for approximately homogeneous field
      4.3.2 Experimental data of breakdown characteristics
      4.3.3 Dimensioning of clearances for homogeneous and
            approximately homogeneous field conditions
  4.4 Inhomogeneous fields
      4.4.1 Conditions for inhomogeneous field
      4.4.2 Experimental data of partial discharge and
            breakdown characteristics
      4.4.3 Dimensioning of clearances for inhomogeneous
            field conditions
5 Creepage distances
  5.1 Experimental data
  5.2 Dimensioning of creepage distances
6 Solid insulation
  6.1 General consideration
  6.2 Influencing factors
  6.3 Dimensioning of solid insulation
7 High-frequency testing
  7.1 Basic requirements
  7.2 Test voltage source
  7.3 Conditioning
  7.4 High-frequency breakdown test
      7.4.1 Test method
      7.4.2 Test result
  7.5 High-frequency partial discharge test
      7.5.1 General considerations
      7.5.2 Test method
      7.5.3 Test equipment
      7.5.4 Test circuit
      7.5.5 Required bandwidth of the test circuit
      7.5.6 Dimensioning of the test circuit
  7.6 Examples of test results
8 Non sinusoidal voltages
  8.1 General considerations
  8.2 Periodic impulse voltage
  8.3 Harmonic analysis
  8.4 Dimensioning procedure and testing
Annex A (informative) Insulation characteristics of
                      clearances at high-frequency
                      voltages
  A.1 Basic information about the breakdown of clearances
  A.2 Experimental data
      A.2.1 Homogeneous and approximately homogeneous field
            distribution
      A.2.2 Inhomogeneous field distribution
Annex B (informative) Insulation characteristics of creepage
                      distances at high-frequency voltages
  B.1 Withstand characteristics of creepage distances
  B.2 Experimental conditions
  B.3 Experimental data
Annex C (informative) Insulation characteristics of solid
                      insulation at high-frequency voltages
  C.1 Degradation mechanism of solid insulation
  C.2 Experimental results
Annex D (normative) Testing of insulation at high-frequency
                    voltages
  D.1 Test voltage source
  D.2 High-frequency partial discharge test
      D.2.1 Test equipment
      D.2.2 Test circuit
  D.3 Examples of test results
Annex E (informative) Insulation stressed with non-sinusoidal
                      high-frequency voltages
  E.1 Objective
  E.2 Harmonic analysis
Annex F (informative) Dimensioning diagrams
Annex ZA (normative) Normative references to international
         publications with their corresponding European publications
Bibliography

Describes basic, supplementary and reinforced insulation subjected to high-frequency voltage stress within low-voltage equipment.

This part of IEC 60664 deals with basic, supplementary and reinforced insulation subjected to high-frequency voltage stress within low-voltage equipment. The dimensioning values directly apply for basic insulation; for reinforced insulation additional requirements apply according to Part 1. It is applicable for the dimensioning of clearances, creepage distances and solid insulation stressed by any type of periodic voltages with a fundamental frequency above 30 kHz and up to 10 MHz.

This part of IEC 60664 can only be used together with IEC 60664-1 or with IEC 60664-5 (in this standard called Part 1 or Part 5). By using Part 1 or Part 5 together with this part the frequency limit of Part 1 or Part 5 is extended to frequencies higher than 30 kHz.

This part also applies to Part 3 for frequencies greater than 30 kHz and protection of type 1. For type 2 protection this question is under consideration.

NOTE 1 Dimensioning values for frequencies above 10 MHz are under consideration.

NOTE 2 This standard does not consider the high-frequency emission to the mains. In normal use of equipment, it is assumed that the interference of high-frequency voltages emitted to the mains is negligible with respect to insulation stress. Therefore it is not necessary to take it into account.

It applies to equipment for use up to 2 000 m above sea level having a rated voltage up to a.c. 1 000 V.

It specifies the requirements for clearances, creepage distances and solid insulation for equipment based upon their performance criteria. lt includes methods of electric testing with respect to insulation coordination.

The minimum clearances specified in this part do not apply where ionized gases occur. Special requirements for such situations may be specified at the discretion of the relevant technical committee.

This part does not deal with distances

  • through liquid insulation,

  • through gases other than air,

  • through compressed air.

NOTE 3 Higher voltages may exist in internal circuits of the equipment.

NOTE 4 Requirements for altitudes exceeding 2 000 m can be derived from Table A.2 of Annex A of Part 1.

The object of this standard is to guide technical committees responsible for different equipment in order to rationalise their requirements so that insulation coordination is achieved when specifying clearances in air, creepage distances and solid insulation for equipment.

Committee
GEL/109
DevelopmentNote
Supersedes 03/100549 DC (04/2006)
DocumentType
Standard
Pages
72
PublisherName
British Standards Institution
Status
Withdrawn
Supersedes

IEC 60112:2003+AMD1:2009 CSV Method for the determination of the proof and the comparative tracking indices of solid insulating materials
IEC 60270:2000+AMD1:2015 CSV High-voltage test techniques - Partial discharge measurements
EN 60112 : 2003 AMD 1 2009 METHOD FOR THE DETERMINATION OF THE PROOF AND THE COMPARATIVE TRACKING INDICES OF SOLID INSULATING MATERIALS
IEC GUIDE 104:2010 The preparation of safety publications and the use of basic safety publications and group safety publications
ISO 7864:2016 Sterile hypodermic needles for single use — Requirements and test methods
EN 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
IEC 60664-5:2007 Insulation coordination for equipment within low-voltage systems - Part 5: Comprehensive method for determining clearances and creepage distances equal to or less than 2 mm
EN 60664-5:2007 Insulation coordination for equipment within low-voltage systems - Part 5: Comprehensive method for determining clearances and creepage distances equal to or less than 2 mm
IEC 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests

View more information
£298.00
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.