• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

BS EN 60870-5-2:1994

Current
Current

The latest, up-to-date edition.

Telecontrol equipment and systems. Transmission protocols Link transmission procedures
Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

15-10-1992

Committees responsible
National foreword
Specification
Introduction
1. Scope and object
1.1 Scope
1.2 Object
2. Normative references
3. Formats and structures of standard transmission
       frames
3.1 Format FT 1.1
3.2 Format FT 1.2
3.3 Format FT 2
3.4 Format FT 3
4. Selection primitives and elements of transmission
       procedures
4.1 SEND/NO REPLY service
4.1.1 Service procedure
4.1.2 Transmission procedure
4.2 SEND/CONFIRM service
4.2.1 Service primitives
4.2.2 Transmission procedure
4.3 REQUEST/RESPOND service
4.3.1 Service primitives
4.3.2 Transmission procedures
5. Unbalanced transmission
5.1 Specification of length, control and address fields
5.1.1 Length field
5.1.2 Control field
5.1.3 Address field
5.2 Unbalanced transmission services
5.3 Unbalanced transmission procedures
5.3.1 SEND/NO procedures
5.3.2 Undisturbed SEND/CONFIRM procedures
5.3.3 Disturbed SEND/CONFIRM procedures
5.3.4 Undisturbed REQUEST/RESPOND procedures
5.3.5 Disturbed REQUEST/RESPOND procedures
6. Balanced transmission
6.1 Specification of length, control and address fields
6.1.1 Length field
6.1.2 Control field
6.1.3 Address field
6.2 Balanced transmission services
6.3 Balanced transmission procedures
6.3.1 SEND/NO REPLY procedures
6.3.2 Undisturbed SEND/CONFIRM procedures
6.3.3 Undisturbed procedures with data flow control
6.3.4 Disturbed SEND/CONFIRM procedures
Annex
A. Time out interval for repeated frame transmission
Tables
1. Unbalanced transmission, function codes of control
     field in messages sent from primary (PRM = 1)
2. Unbalanced transmission, function codes of control
     field in messages sent from secondary (PRM = 0)
3. Balanced transmission, function codes of control
     field in messages sent from primary (PRM = 1)
4. Balanced transmission, function codes of control
     field in messages sent from secondary (PRM = 0)
Figures
1. Relationship between service primitives and
     transmission procedures for basic link services
2. Example of the interaction between a polling
     procedure and an event-initiated transmission
3. Unbalanced transmission procedures, undisturbed
     SEND/CONFIRM procedures
4. Unbalanced transmission procedures, disturbed SEND/
     CONFIRM procedure
5. Unbalanced transmission procedures, undisturbed
     REQUEST/RESPOND procedures
6. Unbalanced transmission procedures, undisturbed
     REQUEST/RESPOND procedures
7. Unbalanced transmission procedures, undisturbed
     REQUEST/RESPOND procedures
8. Unbalanced REQUEST/RESPOND transmission procedures,
     disturbed REQUEST frame
9. Unbalanced REQUEST/RESPOND transmission procedures,
     disturbed RESPOND frame
10. Example of the interaction of service primitives and
     transmission procedures in a balanced system
11. Balanced transmission procedures, undisturbed SEND/
     CONFIRM procedures
12. Balanced transmission procedures, data flow control
13. Balanced transmission procedures, disturbed SEND
     frame
14. Balanced transmission procedures, disturbed SEND and
     ignored CONFIRM frame
15. Balanced transmission procedures, disturbed CONFIRM
     frame
16. Balanced transmission procedures, disturbed channel
     in one direction
A.1 Unbalanced transmission procedures, disturbed
     primary frame
A.2 Unbalanced transmission procedures, disturbed
     secondary frame
A.3 Balanced transmission procedures, disturbed primary
     frame
A.4 Balanced transmission procedures, disturbed
     secondary frame

Requirements with coded bit serial data transmission for monitoring and controlling geographically widespread processes.

This section of IEC 870-5 applies to telecontrol equipment and systems with coded bit serial data transmission for monitoring and controlling geographically widespread processes.

The defined link procedures are restricted to message transmission sequences operating with size 1 windows. This means that the link layer of the primary station (station that initiates a message transfer) accepts a request for a new message transfer only when a previously accepted request for a message transfer is terminated either successfully or with an error indication. The procedures are applicable to balanced and unbalanced transmission in telecontrol systems using half duplex or duplex transmission channels.

Committee
PEL/57
DevelopmentNote
Renumbers and supersedes BS 7404-5.2(1992). 1994 version incorporates amendment 8114 to BS 7404-5.2(1992). Supersedes 89/27230 DC. Also numbered as IEC 60870-5-2. (12/2005)
DocumentType
Standard
Pages
48
PublisherName
British Standards Institution
Status
Current
Supersedes

Standards Relationship
I.S. EN 60870-5-2:1994 Identical
EN 60870-5-2:1993 Identical
SN EN 60870-5-2 : 1993 Identical
DIN EN 60870-5-2:1994-07 Identical

BS EN 60870-2-1:1996 Telecontrol equipment and systems. Operating conditions Power supply and electromagnetic compatibility
BS EN 60870-2-2:1997 Telecontrol equipment and systems. Operating conditions Environmental conditions (climatic, mechanical and other non-electrical influences)
BS 7404-1.4:1995 Telecontrol equipment and systems. General considerations Guide for basic aspects of telecontrol data transmission and organization of standards BS 7404:Part 5 and BS 7404:Part 6
BS EN 60870-5-5:1996 Telecontrol equipment and systems. Transmission protocols Basic application functions
BS EN 60870-5-102:1997 Telecontrol equipment and systems. Transmission protocols Companion standard for the transmission of integrated totals in electric power systems

BS 7404-5.1(1991) : 1991 AMD 8113 TELECONTROL EQUIPMENT AND SYSTEMS - TRANSMISSION PROTOCOLS - SPECIFICATION FOR TRANSMISSION FRAME FORMATS
EN 60870-5-1:1993 Telecontrol equipment and systems - Part 5: Transmission protocols - Section 1: Transmission frame formats
BS 7404-1.1:1991 Telecontrol equipment and systems. General considerations. General principles
IEC TR 60870-1-1:1988 Telecontrol equipment and systems. Part 1: General considerations. Section One: General principles
IEC 60870-5-1:1990 Telecontrol equipment and systems. Part 5: Transmission protocols - Section One: Transmission frame formats
IEC 60050-371:1984 International Electrotechnical Vocabulary (IEV) - Part 371: Telecontrol

View more information
£262.00
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.