1 General
2 Definitions
3 Classification
4 Characteristics
5 Product information
6 Normal service, mounting and transport conditions
7 Constructional and performance requirements
8 Tests
Annex A (informative) - Harmonisation of utilization
        categories for low-voltage switchgear and
        controlgear
Annex B (informative) - Suitability of the equipment when
         conditions for operation in service differ from the
         normal conditions
Annex C (normative) - Degrees of protection of enclosed
        equipment
Annex D (informative) - Examples of clamping units and
        relationship between clamping unit and
        connecting device
Annex E (informative) - Description of a method for adjusting
        the load circuit
Annex F (informative) - Determination of short-circuit power-
        factor or time-constant
Annex G (informative) - Measurement of creepage distances
        and clearances
Annex H (informative) - Correlation between the nominal
        voltage of the supply system and the rated impulse
        withstand voltage of equipment
Annex J (informative) - Items subject to agreement between
        manufacturer and user
Annex K (normative) - Procedure to determine reliability
        data for electromechanicald devices use in functional
        safety applications
Annex L (normative) - Terminal marking and distinctive
        number
Annex M (normative) - Flammability test
Annex N (normative) - Requirements and tests for equipment with
        protective separation
Annex O (informative) - Environmentally-conscious design
Annex P (informative) - Terminal lugs for low voltage
        switchgear and controlgear connected to copper
        conductors
Annex Q (normative) - Special tests - Damp heat, salt mist,
        vibration and shock
Annex R (normative) - Application of the metal foil for
        dielectric testing on accessible parts during operation
        or adjustment
Annex S (normative) - Digital inputs and outputs
Annex T (normative) - Extended functions within electronic
        overload relays
Annex U (informative) - Examples of control circuit
        configurations
Annex V (informative) - Power management with switchgear
        and controlgear for electrical energy efficiency
Annex W (normative) - Procedure to establish material
        declaration
Annex ZA (normative) - Normative references to
         international publications with their corresponding
         European publications
Annex ZZ (informative) Coverage of Essential Requirements
         of EU Directives
Bibliography

Applicable to, when required by the relevant product standard, to switchgear and controlgear hereinafter referred to as 'equipment' and intended to be connected to circuits, the rated voltage of which does not exceed 1000 V a.c. or 1500 V d.c.

Committee
PEL/17/2
DevelopmentNote
Supersedes 96/206168 DC, 96/207792 DC and 99/202934 DC (06/2002) Supersedes 02/206413 DC and 91/03179 DC (09/2004) Supersedes 98/203571 DC. (05/2005) Supersedes 08/30176293 DC.(05/2011) 2007 Edition Re-Issued in December 2014 & incorporates AMD 2 2014. Supersedes 11/30249097 DC. (01/2015)
DocumentType
Standard
Pages
268
PublisherName
British Standards Institution
Status
Current
Supersedes

BS EN 147000:1995 Harmonized system of quality assessment for electronic components. Generic specification. Sockets for use with electrical relays of assessed quality
BS 7856:2017 Specification for special design and other features of alternating current watthour meters for active energy for use in the UK (Accuracy Classes A and B)
BS 6440:1999 Powered lifting platforms for use by disabled persons. Code of practice
BS 6440:2011 Powered vertical lifting platforms having non-enclosed or partially enclosed liftways intended for use by persons with impaired mobility. Specification
09/30181298 DC : 0 BS 7657 - SPECIFICATION FOR FUSES (CUT-OUTS), ANCILLARY TERMINAL BLOCKS AND INTERCONNECTING UNITS UP TO 100 A RATING, FOR POWER SUPPLIES TO BUILDINGS
09/30181290 DC : 0 BS 7654 - SPECIFICATION FOR SINGLE-PHASE STREET LIGHTING FUSES (CUT-OUTS) FOR LOW-VOLTAGE PUBLIC ELECTRICITY DISTRIBUTION SYSTEMS - 25 A RATING FOR HIGHWAY POWER SUPPLIES AND STREET FURNITURE
DEFSTAN 02-122/1(2002) : INTERIM REQUIREMENTS FOR CATERING EQUIPMENT
BS 7657:1993 Specification for fuses (cut-outs), ancillary terminal blocks and interconnecting units up to 100 A rating, for power supplies to buildings
93/210506 DC : DRAFT AUG 1993 EN 50156 ELECTRICAL EQUIPMENT FOR FURNACES - PART 1 RULES FOR INSTALLATION (PREN 50156-1)
BS 5900:2012 Powered homelifts with partially enclosed carriers and no liftway enclosures. Specification
BS 7654:1997 Specification for single phase street lighting fuses (cut-outs) for low-voltage public electricity distribution systems. 25 A rating for highway power supplies and street furniture
BS 7654:2010 Specification for single-phase street lighting cut-out assemblies for low-voltage public electricity distribution systems. 25 A rating for highway power supplies and street furniture
BS 6423:2014 Code of practice for maintenance of low-voltage switchgear and controlgear
13/30283398 DC : 0 BS 7656+A1 - SPECIFICATION FOR LOW-VOLTAGE POLE-MOUNTING FUSES (CUT-OUTS) - 315 ARATING
ENA ER G81-2 : ISSUE 2 2016 FRAMEWORK FOR NEW LOW VOLTAGE HOUSING DEVELOPMENT INSTALLATIONS - PART 2: MATERIALS SPECIFICATION
DD ENV 1954:1997 Internal and external fault behaviour of safety related electronic parts of gas appliances
BS 7656(1993) : 1993 SPECIFICATION FOR LOW-VOLTAGE POLE-MOUNTING FUSES (CUT-OUTS) - 400 A RATING
11/30194294 DC : 0 BS 6440 - POWERED LIFTING PLATFORMS WITH NON-ENCLOSED LIFTWAYS FOR USE BY PERSONS WITH LIMITED MOBILITY - SPECIFICATION
BS EN 61330:1996 High-voltage/low-voltage prefabricated substations
14/30295814 DC : 0 BS 8489-1 - FIXED FIRE PROTECTION SYSTEMS - INDUSTRIAL AND COMMERCIAL WATERMIST SYSTEMS - PART 1: CODE OF PRACTICE FOR DESIGN AND INSTALLATION
BS 7657:2010 Specification for cut-out assemblies up to 100 A rating, for power supply to buildings
BS DD8489-1(2011) : 2011 FIXED FIRE PROTECTION SYSTEMS - INDUSTRIAL AND COMMERCIAL WATERMIST SYSTEMS - PART 1: CODE OF PRACTICE FOR DESIGN AND INSTALLATION
11/30194292 DC : 0 BS 5900 - POWERED HOME LIFTS WITH FULLY OR PARTIALLY ENCLOSED CARS AND NO LIFT-WELL ENCLOSURES - SPECIFICATION
ENA ER G81-5 : ISSUE 2 2016 FRAMEWORK FOR NEW INDUSTRIAL AND COMMERCIAL UNDERGROUND CONNECTIONS - PART 5: MATERIALS SPECIFICATION
16/30348626 DC : 0 BS 7856:2017 - SPECIFICATION FOR SPECIAL DESIGN AND OTHER FEATURES OF ALTERNATING CURRENT WATTHOUR METERS FOR ACTIVE ENERGY FOR USE IN THE UK (ACCURACY CLASSES A AND B)
BS EN 116000-3:1996 Harmonized system of quality assessment for electronic components. Generic specification: electromechanical all-or-nothing relays Test and measurement procedures
BS 8489-1:2016 Fixed fire protection systems. Industrial and commercial watermist systems Code of practice for design and installation
BS 4163:2007 HEALTH AND SAFETY FOR DESIGN AND TECHNOLOGY IN SCHOOLS AND SIMILAR ESTABLISHMENTS - CODE OF PRACTICE
BS 4163:2000 HEALTH AND SAFETY FOR DESIGN AND TECHNOLOGY IN SCHOOLS AND SIMILAR ESTABLISHMENTS - CODE OF PRACTICE

IEC 61000-4-8 : 2.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-8: TESTING AND MEASUREMENT TECHNIQUES - POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST
IEC 60112:2003+AMD1:2009 CSV Method for the determination of the proof and the comparative tracking indices of solid insulating materials
EN 60999-2:2003 Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 2: Particular requirements for clamping units for conductors above 35 mm² up to 300 mm² (included)
IEC TR 61912-1:2007 Low-voltage switchgear and controlgear - Overcurrent protective devices - Part 1: Application of short-circuit ratings
IEC 60947-6-2:2002+AMD1:2007 CSV Low-voltage switchgear and controlgear - Part 6-2: Multiple function equipment - Control and protective switching devices (or equipment) (CPS)
EN 60947-8:2003/A2:2012 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 8: CONTROL UNITS FOR BUILT-IN THERMAL PROTECTION (PTC) FOR ROTATING ELECTRICAL MACHINES (IEC 60947-8:2003/A2:2011)
IEC 60947-8:2003+AMD1:2006+AMD2:2011 CSV Low-voltage switchgear and controlgear - Part 8: Control units for built-in thermal protection (PTC) for rotating electrical machines
IEC 60228:2004 Conductors of insulated cables
HD 60364-4-443:2016 Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances - Clause 443: Protection against transient overvoltages of atmospheric origin or due to switching
EN 61557-2:2007 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 2: Insulation resistance
IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
IEC 61000-4-4 : 3.0EN+(REDLINE+VERSION) ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST
IEC 60068-2-27:2008 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
IEC 60947-4-1:2009+AMD1:2012 CSV Low-voltage switchgear and controlgear - Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor-starters
EN 60085:2008 Electrical insulation - Thermal evaluation and designation
EN 61000-4-11:2004/A1:2017 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017)
IEC 61000-6-2:2016 Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
IEC 60073:2002 Basic and safety principles for man-machine interface, marking and identification - Coding principles for indicators and actuators
IEC 61649:2008 Weibull analysis
EN 61131-2:2007 Programmable controllers - Part 2: Equipment requirements and tests
EN 60073:2002 Basic and safety principles for man-machine interface, marking and identification - Coding principles for indicators and actuators
IEC 60050-151:2001 International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices
IEC 61000-4-11:2004+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
EN 61000-3-3:2013 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-3: LIMITS - LIMITATION OF VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER IN PUBLIC LOW-VOLTAGE SUPPLY SYSTEMS, FOR EQUIPMENT WITH RATED CURRENT <= 16 A PER PHASE AND NOT SUBJECT TO CONDITIONAL CONNECTION (IEC 61000-3-3:2013)
IEC 60050-441:1984 International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses
EN 60068-1:2014 Environmental testing - Part 1: General and guidance
IEC 60999-2:2003 Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 2: Particular requirements for clamping units for conductors above 35 mm2 up to 300 mm2 (included)
IEC 60269-2:2013+AMD1:2016 CSV Low-voltage fuses - Part 2: Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application) - Examples of standardized systems of fuses A to K
IEC 62430:2009 Environmentally conscious design for electrical and electronic products
IEC 61000-4-8:2009 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 60947-5-1 : 4.0 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 5-1: CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS - ELECTROMECHANICAL CONTROL CIRCUIT DEVICES
IEC 61000-4-4:2012 RLV Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 60092-504:2016 Electrical installations in ships - Part 504: Automation, control and instrumentation
EN 61000-4-2:2009 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 60695-2-11:2014 Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT)
EN 60228:2005 COR 2005 CONDUCTORS OF INSULATED CABLES
ISO 50001:2011 Energy management systems Requirements with guidance for use
IEC 60269-1:2006+AMD1:2009+AMD2:2014 CSV Low-voltage fuses - Part 1: General requirements
IEC 60947-7-1:2009 Low-voltage switchgear and controlgear - Part 7-1: Ancillary equipment - Terminal blocks for copper conductors
EN 61649:2008 Weibull analysis
EN 60216 : 1990
WC 8:1988 ETHYLENE-PROPYLENE-RUBBER-INSULATED WIRE AND CABLE FOR THE TRANSMISSION AND DISTRIBUTION OF ELECTRICAL ENERGY
IEC TR 62380:2004 Reliability data handbook - Universal model for reliability prediction of electronics components, PCBs and equipment
EN 60112 : 2003 AMD 1 2009 METHOD FOR THE DETERMINATION OF THE PROOF AND THE COMPARATIVE TRACKING INDICES OF SOLID INSULATING MATERIALS
IEC 61000-4-6 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS
IEC 60999-1:1999 Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm2 up to 35 mm2 (included)
ASTM B 172 : 2017 : REDLINE Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Members, for Electrical Conductors
IEC 61000-4-6:2013 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
CISPR 22:2008 Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement
EN 61000-4-3 : 2006 AMD 2 2010 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST
IEC 60085:2007 Electrical insulation - Thermal evaluation and designation
IEC 61557-2:2007 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 2: Insulation resistance
EN 60068-2-27:2009 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
EN 60447:2004 Basic and safety principles for man-machine interface, marking and identification - Actuating principles
IEC 60695-2-12:2010+AMD1:2014 CSV Fire hazard testing - Part 2-12: Glowing/hot-wire based test methods- Glow-wire flammability index (GWFI) test method for materials
IEC 60998-2-2:2002 Connecting devices for low-voltage circuits for household and similar purposes - Part 2-2: Particular requirements for connecting devices as separate entities with screwless-type clamping units
IEC 60447:2004 Basic and safety principles for man-machine interface, marking and identification - Actuating principles
IEC 60050-603:1986 International Electrotechnical Vocabulary (IEV) - Part 603: Generation, transmission and distribution of electricity - Power systems planning and management
EN 61000-6-2:2005/corrigendum:2005 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY FOR INDUSTRIAL ENVIRONMENTS (IEC 61000-6-2:2005)
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
IEC TR 60344:2007 Calculation of d.c. resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide
EN 61000-4-8:2010 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
EN 60695-2-10:2013 Fire hazard testing - Part 2-10: Glowing/hot-wire based test methods - Glow-wire apparatus and common test procedure
IEC 60364-4-44:2007+AMD1:2015 CSV Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances
IEC 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 60695-11-10:2013 Fire hazard testing - Part 11-10: Test flames - 50 W horizontal and vertical flame test methods
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
EN 62430:2009 Environmentally conscious design for electrical and electronic products
IEC 60947-4-2:2011 Low-voltage switchgear and controlgear - Part 4-2: Contactors and motor-starters - AC semiconductor motor controllers and starters
EN 62061:2005/A2:2015 SAFETY OF MACHINERY - FUNCTIONAL SAFETY OF SAFETY-RELATED ELECTRICAL, ELECTRONIC AND PROGRAMMABLE ELECTRONIC CONTROL SYSTEMS (IEC 62061:2005/A2:2015)
EN 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
IEC 60439-1:1999+AMD1:2004 CSV Low-voltage switchgear and controlgear assemblies - Part 1: Type-tested and partially type-tested assemblies
EN 60071-1:2006/A1:2010 INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES
WC 3-1992 RUBBER-INSULATED WIRE AND CABLE FOR THE TRANSMISSION AND DISTRIBUTION OF ELECTRICAL ENERGY
IEC 60664-5:2007 Insulation coordination for equipment within low-voltage systems - Part 5: Comprehensive method for determining clearances and creepage distances equal to or less than 2 mm
IEC 61000-3-3:2013 RLV Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
EN 60269-2:1995/A2:2002 LOW-VOLTAGE FUSES - SUPPLEMENTARY REQUIREMENTS FOR FUSES FOR USE BY AUTHORIZED PERSONS (FUSES MAINLY FOR INDUSTRIAL APPLICATION)
EN 61000-3-2:2014 Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61095:2009 Electromechanical contactors for household and similar purposes
IEC 60050-461:2008 International Electrotechnical Vocabulary (IEV) - Part 461: Electric cables
EN 60068-2-78:2013 Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
EN 60068-2-6:2008 Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
EN 62474:2012 Material declaration for products of and for the electrotechnical industry
IEC 61131-2:2017 Industrial-process measurement and control - Programmable controllers - Part 2: Equipment requirements and tests
IEC 60050-826:2004 International Electrotechnical Vocabulary (IEV) - Part 826: Electrical installations
IEC 61000-3-3 : 3.0EN+(REDLINE+VERSION) ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-3: LIMITS - LIMITATION OF VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER IN PUBLIC LOW-VOLTAGE SUPPLY SYSTEMS, FOR EQUIPMENT WITH RATED CURRENT <= 16 A PER PHASE AND NOT SUBJECT TO CONDITIONAL CONNECTION
EN ISO 13849-1:2015 Safety of machinery - Safety-related parts of control systems - Part 1: General principles for design (ISO 13849-1:2015)
IEC 60664-3:2016 Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution
EN 61000-4-4:2012 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012)
EN 60999-1:2000 Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm² up to 35 mm² (included)
CISPR 11:2015 RLV Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
EN 61140:2016 Protection against electric shock - Common aspects for installation and equipment
IEC 60947-5-2:2007+AMD1:2012 CSV Low-voltage switchgear and controlgear - Part 5-2: Control circuitdevices and switching elements - Proximity switches
IEC 61508-6:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 6: Guidelines on the application of IEC 61508-2 and IEC 61508-3 (see Functional Safety and IEC 61508)
IEC 60947-3:2008+AMD1:2012+AMD2:2015 CSV Low-voltage switchgear and controlgear - Part 3: Switches, disconnectors, switch-disconnectors and fuse-combination units
EN 60068-2-11:1999 Environmental testing - Part 2: Tests - Test Ka: Salt mist
IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
EN 61000-4-6:2014/AC:2015 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013)
EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
IEC 62061:2005+AMD1:2012+AMD2:2015 CSV Safety of machinery - Functional safety of safety-related electrical, electronic and programmable electronic control systems
EN 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
IEC 61140:2016 Protection against electric shock - Common aspects for installation and equipment
EN 60664-5:2007 Insulation coordination for equipment within low-voltage systems - Part 5: Comprehensive method for determining clearances and creepage distances equal to or less than 2 mm
IEC 60071-1:2006+AMD1:2010 CSV Insulation co-ordination - Part 1: Definitions, principles and rules
IEC 60695-11-5 : 2.0 FIRE HAZARD TESTING - PART 11-5: TEST FLAMES - NEEDLE-FLAME TEST METHOD - APPARATUS, CONFIRMATORY TEST ARRANGEMENT AND GUIDANCE
IEC 60695-11-5:2016 Fire hazard testing - Part 11-5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance
IEC 60695-2-10:2013 Fire hazard testing - Part 2-10: Glowing/hot-wire based test methods - Glow-wire apparatus and common test procedure
IEC 60947-4-3:2014 Low-voltage switchgear and controlgear - Part 4-3: Contactors and motor-starters - AC semiconductor controllers and contactors for non-motor loads
IEC 60947-6-1:2005+AMD1:2013 CSV Low-voltage switchgear and controlgear - Part 6-1: Multiple functionequipment - Transfer switching equipment
EN 60695-2-12:2010/A1:2014 FIRE HAZARD TESTING - PART 2-12: GLOWING/HOT-WIRE BASED TEST METHODS - GLOW-WIRE FLAMMABILITY INDEX (GWFI) TEST METHOD FOR MATERIALS (IEC 60695-2-12:2010/A1:2014)
ISO 13849-1:2015 Safety of machinery — Safety-related parts of control systems — Part 1: General principles for design
IEC 61000-6-2 : 3.0:2016 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY STANDARD FOR INDUSTRIAL ENVIRONMENTS
IEC 60445:2017 Basic and safety principles for man-machine interface, marking and identification - Identification of equipment terminals, conductor terminations and conductors
IEC 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
IEC 60068-2-52:2017 Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution)
EN 60664-3:2017 Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution
EN 61000-4-13:2002/A2:2016 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-13: TESTING AND MEASUREMENT TECHNIQUES - HARMONICS AND INTERHARMONICS INCLUDING MAINS SIGNALLING AT A.C. POWER PORT, LOW FREQUENCY IMMUNITY TESTS (IEC 61000-4-13:2002/A2:2015)
IEC 62474:2012 Material declaration for products of and for the electrotechnical industry
EN 60695-2-2:1994/A1:1995 FIRE HAZARD TESTING - TEST METHODS - NEEDLE-FLAME TEST
IEC 61000-4-13:2002+AMD1:2009+AMD2:2015 CSV Electromagnetic compatibility (EMC) - Part 4-13: Testing and measurement techniques - Harmonics and interharmonics includingmains signalling at a.c. power port, low frequency immunity tests
IEC 60981:2004 Extra heavy-duty electrical rigid steel conduits
IEC 60300-3-5:2001 Dependability management - Part 3-5: Application guide - Reliability test conditions and statistical test principles
EN 60695-2-11:2014 Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) (IEC 60695-2-11:2014)
WC 7-1988 CROSS-LINKED-THERMOSETTING-POLYETHYLENE-INSULATED WIRE AND CABLE FOR THE TRANSMISSION AND DISTRIBUTION OF ELECTRICAL ENERGY
EN 60269-1:2007/A2:2014 LOW-VOLTAGE FUSES - PART 1: GENERAL REQUIREMENTS (IEC 60269-1:2006/A2:2014)
IEC 61000-3-2 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-2: LIMITS - LIMITS FOR HARMONIC CURRENT EMISSIONS (EQUIPMENT INPUT CURRENT <= 16 A PER PHASE)
IEC 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)

View more information
£400.00
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.