• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

BS EN 61000-3-12:2011

Current
Current

The latest, up-to-date edition.

Electromagnetic compatibility (EMC) Limits. Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current > 16 A and ≤ 75 A per phase
Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

31-10-2013

INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Measurement conditions
5 Requirements and limits for equipment
6 Product documentation
7 Test and simulation conditions
Annex A (normative) - Type test conditions
Annex B (informative) - Illustration of limits for
        harmonic currents
Annex C (informative) - Equipment not complying with
        the requirements and limits of this standard
Bibliography
Annex ZA (normative) - Normative references to
         international publications with their
         corresponding European publications
Annex ZZ (informative) - Coverage of Essential
         Requirements of EU Directives

Defines the limitation of harmonic currents injected into the public supply system.

This part of IEC 61000 deals with the limitation of harmonic currents injected into the public supply system. The limits given in this International Standard are applicable to electrical and electronic equipment with a rated input current exceeding 16 A and up to and including 75 A per phase, intended to be connected to public low-voltage a.c. distribution systems of the following types: nominal voltage up to 240 V, single-phase, two or three wires; nominal voltage up to 690 V, three-phase, three or four wires; nominal frequency 50 Hz or 60 Hz. Other distribution systems are excluded. The limits given in this edition apply to equipment when connected to 230/400 V, 50 Hz systems. See also Clause 5. NOTE 1 The limits for the other systems will be added in a future edition of this standard. NOTE 2 Equipment with a rated input current exceeding 75 A per phase should be considered in the harmonic current requirements for installations. See IEC /TR 61000-3-6 and future IEC/TR 61000-3-14. This standard applies to equipment intended to be connected to low-voltage systems interfacing with the public supply at the low-voltage level. It does not apply to equipment intended to be connected only to private low-voltage systems interfacing with the public supply only at the medium- or high-voltage level. NOTE 3 The scope of this standard is limited to equipment connected to public low voltage systems because emissions from equipment installed in private low voltage systems can be controlled in aggregate at the MV point of common coupling using procedures defined in IEC/TR 61000-3-6 and/or by means of contractual agreements between the distribution network operator and the customer. It is expected that operators of private systems will manage the EMC environment in a manner that ensures compliance with the provisions given in IEC /TR 61000-3-6 and/or the contractual agreements. NOTE 4 If the equipment is intended to be connected only to private systems, the manufacturer should make this very clear in the product documentation. NOTE 5 Professional equipment with input current ≤16 A per phase and that does not comply with the requirements and limits of standard IEC 61000-3-2 may be permitted to be connected to certain types of low voltage supplies, in the same way as equipment with input current >16 A per phase and that does not comply with the requirements and limits of the present standard (see Annex C). NOTE 6 The limits in this standard are not applicable to stand -alone harmonic filters. This standard defines: requirements and emission limits for equipment; methods for type tests and simulations. Tests according to this International Standard are type tests of complete pieces of equipment. Conformity with this standard can also be determined by validated simulations.

Committee
GEL/210
DevelopmentNote
Supersedes 00/244985 DC. (06/2006) Supersedes 08/30183041 DC. (02/2012)
DocumentType
Standard
Pages
30
PublisherName
British Standards Institution
Status
Current
Supersedes

08/30136724 DC : DRAFT MAY 2008 BS 6739 - CODE OF PRACTICE FOR INSTRUMENTATION IN PROCESS CONTROL SYSTEMS - INSTALLATION DESIGN AND PRACTICE
ENA ER G100 : ISSUE 1 AMD 1 2017 TECHNICAL GUIDANCE FOR CUSTOMER EXPORT LIMITING SCHEMES
16/30336434 DC BS EN 54-27:2015 AMD 1:2016 - FIRE DETECTION AND FIRE ALARMS SYSTEMS - PART 27: DUCT SMOKE DETECTORS

IEC TR 61000-2-6:1995 Electromagnetic compatibility (EMC) - Part 2: Environment - Section 6: Assessment of the emission levels in the power supply of industrial plants as regards low-frequency conducted disturbances
IEC TR 61000-3-14:2011 Electromagnetic compatibility (EMC) - Part 3-14: Assessment of emission limits for harmonics, interharmonics, voltage fluctuations and unbalance for the connection of disturbing installations to LV power systems
IEC 60038:2009 IEC standard voltages
IEC GUIDE 107:2014 Electromagnetic compatibility - Guide to the drafting of electromagnetic compatibility publications
IEC 61000-2-4:2002 Electromagnetic compatibility (EMC) - Part 2-4: Environment - Compatibility levels in industrial plants for low-frequency conducted disturbances
EN 61000-2-4:2002/AC:2014 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 2-4: ENVIRONMENT - COMPATIBILITY LEVELS IN INDUSTRIAL PLANTS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES
EN 61000-4-7:2002/A1:2009 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-7: TESTING AND MEASUREMENT TECHNIQUES - GENERAL GUIDE ON HARMONICS AND INTERHARMONICS MEASUREMENTS AND INSTRUMENTATION, FOR POWER SUPPLY SYSTEMS AND EQUIPMENT CONNECTED THERETO (IEC 61000-4-7:2002/A1:2008)
EN 61000-2-2:2002/A1:2017 ELECTROMAGNETIC COMPATIBILITY (EMC) - ENVIRONMENT - COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC LOW-VOLTAGE POWER SUPPLY SYSTEMS (IEC 61000-2-2:2002/A1:2017)
IEC TR 61000-1-4:2005 Electromagnetic compatibility (EMC) - Part 1-4: General - Historical rationale for the limitation of power-frequency conducted harmonic current emissions from equipment, in the frequency range up to 2 kHz
IEC TS 61000-3-4:1998 Electromagnetic compatibility (EMC) - Part 3-4: Limits - Limitation of emission of harmonic currents in low-voltage power supply systems for equipment with rated current greater than 16 A
IEC 61000-2-2:2002+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 2-2: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems
EN 61000-3-2:2014 Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-4-7:2002+AMD1:2008 CSV Electromagnetic compatibility (EMC) - Part 4-7: Testing and measurement techniques - General guide on harmonics and interharmonics measurements and instrumentation, for power supply systems and equipment connected thereto
IEC TR 61000-3-6:2008 Electromagnetic compatibility (EMC) - Part 3-6: Limits - Assessment of emission limits for the connection of distorting installations to MV, HV and EHV power systems
EN 60038 : 2011 CENELEC STANDARD VOLTAGES (IEC 60038:2009, MODIFIED)
IEC 61000-3-2 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-2: LIMITS - LIMITS FOR HARMONIC CURRENT EMISSIONS (EQUIPMENT INPUT CURRENT <= 16 A PER PHASE)

View more information
£198.00
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.