IEC 61158-2:2014 specifies the requirements for fieldbus component parts. It also specifies the media and network configuration requirements necessary to ensure agreed levels of data integrity before data-link layer error checking and interoperability between devices at the physical layer. The fieldbus physical layer conforms to layer 1 of the OSI 7-layer model as defined by ISO 7498 with the exception that, for some types, frame delimiters are in the physical layer while for other types they are in the data-link layer. This sixth edition cancels and replaces the fifth edition published in 2010. It constitutes a technical revision. This edition includes the following changes:
- new Type 20 specification;
- new Type 24 specification;
- RS232 media specification for Type 4 removed.
Committee |
GEL/65/3
|
DevelopmentNote |
Together with BS EN 61158-3, BS EN 61158-4, BS EN 61784-1 and BS EN 61158-5 it supersedes BS EN 50170 and BS EN 50254. (09/2004) Supersedes 01/617087 DC, 01/617088 DC, 01/617089 DC, 01/617090 DC, 01/617091 DC, 01/617092 DC, 00/617092 DC and 01/617093 DC. (06/2005) Supersedes 93/617007 DC and 96/617048 DC. (09/2007) Together with BS PD IEC TR 61491, BS EN 61158-3-16, -4-16, -5-16, -6-16, BS EN 61784-1, BS EN 61800-7-1, -204, -304, it supersedes BS EN 61491. (04/2010) Supersedes 09/30205023 DC. (11/2010) Supersedes 12/30264905 DC. (11/2014)
|
DocumentType |
Standard
|
Pages |
480
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
|
Standards | Relationship |
IEC 61158-2:2014 | Identical |
EN 61158-2:2014 | Identical |
NF EN 61158-2 : 2015 | Identical |
DIN EN 61158-2:2015-02 | Identical |
I.S. EN 61158-2:2014 | Identical |
SN EN 61158-2 : 2014 | Identical |
NBN EN 61158-2 : 2014 | Identical |
IEC 60255-22-1:2007 | Measuring relays and protection equipment - Part 22-1: Electrical disturbance tests - 1 MHz burst immunity tests |
ISO 4892-1:2016 | Plastics Methods of exposure to laboratory light sources Part 1: General guidance |
IEC 60364-5-54:2011 | Low-voltage electrical installations - Part 5-54: Selection and erection of electrical equipment - Earthing arrangements and protective conductors |
IEC 61158-4-20:2014 | Industrial communication networks - Fieldbus specifications - Part 4-20: Data-link layer protocol specification - Type 20 elements |
IEC 61158-4-7:2007 | Industrial communication networks - Fieldbus specifications - Part 4-7: Data-link layer protocol specification - Type 7 elements |
EN 61754-2:1997 | Fibre optic connector interfaces - Part 2: Type BFOC/2,5 connector family |
IEC 61169-8:2007 | Radio-frequency connectors - Part 8: Sectional specification - RF coaxial connectors with inner diameter of outer conductor 6,5 mm (0,256 in) with bayonet lock - Characteristic impedance 50 Ω (type BNC) |
TIA/EIA 422 : B1994(R2014) | ELECTRICAL CHARACTERISTICS OF BALANCED VOLTAGE DIGITAL INTERFACE CIRCUITS |
IEC 61158-4-1:2014 | Industrial communication networks - Fieldbus specifications - Part 4-1: Data-link layer protocol specification - Type 1 elements |
IEC 60807-3:1990 | Rectangular connectors for frequencies below 3 MHz - Part 3: Detail specification for a range of connectors with trapezoidal shaped metal shells and round contacts - Removable crimp contact types with closed crimp barrels, rear insertion/rear extraction |
IEC 61784-1:2014 | Industrial communication networks - Profiles - Part 1: Fieldbus profiles |
ISO/IEC 7498-1:1994 | Information technology Open Systems Interconnection Basic Reference Model: The Basic Model |
EN 60754-2:2014 | Test on gases evolved during combustion of materials from cables - Part 2: Determination of acidity (by pH measurement) and conductivity |
IEC 61000-4-4 : 3.0EN+(REDLINE+VERSION) | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST |
EN ISO 4892-1:2016 | Plastics - Methods of exposure to laboratory light sources - Part 1: General guidance (ISO 4892-1:2016) |
IEC 60189-1:2007 | Low-frequency cables and wires with PVC insulation and PVC sheath - Part 1: General test and measuring methods |
IEC 60364-4-41:2005+AMD1:2017 CSV | Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock |
IEC 61754-22:2005 | Fibre optic connector interfaces - Part 22: Type F-SMA connector family |
EN 61131-2:2007 | Programmable controllers - Part 2: Equipment requirements and tests |
ISO/IEC 8886:1996 | Information technology Open Systems Interconnection Data link service definition |
IEC 60793-2-30:2015 | Optical fibres - Part 2-30: Product specifications - Sectional specification for category A3 multimode fibres |
EN 61754-22:2005 | Fibre optic connector interfaces - Part 22: Type F-SMA connector family |
IEC 61210:2010 | Connecting devices - Flat quick-connect terminations for electrical copper conductors - Safety requirements |
EN 61754-13:2006 | Fibre optic connector interfaces - Part 13: Type FC-PC connector |
IEC 61596:1995 | Magnetic oxide EP-cores and associated parts for use in inductors and transformers - Dimensions |
IEC 60794-1-2:2017 | Optical fibre cables - Part 1-2: Generic specification - Basic optical cable test procedures - General guidance |
HD 60364-4-41:2017/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-41: PROTECTION FOR SAFETY - PROTECTION AGAINST ELECTRIC SHOCK |
HD 60364-5-54:2011/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-54: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - EARTHING ARRANGEMENTS AND PROTECTIVE CONDUCTORS |
EN 60793-2-40:2016 | Optical fibres - Part 2-40: Product specifications - Sectional specification for category A4 multimode fibres |
EN 61169-8:2007 | Radio-frequency connectors - Part 8: Sectional specification - RF coaxial connectors with inner diameter of outer conductor 6,5 mm (0,256 in) with bayonet lock - Characteristic impedance 50 ohms (type BNC) |
IEC 60793-2-40:2015 | Optical fibres - Part 2-40: Product specifications - Sectional specification for category A4 multimode fibres |
IEC 61158-4-12:2014 | Industrial communication networks - Fieldbus specifications - Part 4-12: Data-link layer protocol specification - Type 12 elements |
ISO/IEC 8802-3:2000 | Information technology Telecommunications and information exchange between systems Local and metropolitan area networks Specific requirements Part 3: Carrier sense multiple access with collision detection (CSMA/CD) access method and physical layer specifications |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
EN 61000-4-2:2009 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
ISO/IEC 10731:1994 | Information technology Open Systems Interconnection Basic Reference Model Conventions for the definition of OSI services |
EN 61158-4-3:2014 | Industrial communication networks - Fieldbus specifications - Part 4-3: Data-link layer protocol specification - Type 3 elements |
IEC 61754-2:1996 | Fibre optic connector interfaces - Part 2: Type BFOC/2,5 connector family |
EN 61000-4-3 : 2006 AMD 2 2010 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST |
EN 60079-11:2012 | Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" |
IEC 60079-11:2011 | Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" |
IEC 61754-13:2006 | Fibre optic connector interfaces - Part 13: Type FC-PC connector |
EN 60079-25:2010/AC:2013 | EXPLOSIVE ATMOSPHERES - PART 25: INTRINSICALLY SAFE ELECTRICAL SYSTEMS (IEC 60079-25:2010) |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
EN 60793-2-30:2015 | Optical fibres - Part 2-30: Product specifications - Sectional specification for category A3 multimode fibres |
IEC 60754-2:2011 | Test on gases evolved during combustion of materials from cables - Part 2: Determination of acidity (by pH measurement) and conductivity |
EN 61158-4-2:2014 | Industrial communication networks - Fieldbus specifications -Part 4-2: Data-link layer protocol specification - Type 2 elements |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
IEC 60079-25:2010 | Explosive atmospheres - Part 25: Intrinsically safe electrical systems |
IEC 61300-3-4:2012 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-4: Examinations and measurements - Attenuation |
IEC 61156-1:2007+AMD1:2009 CSV | Multicore and symmetrical pair/quad cables for digital communications - Part 1: Generic specification |
ISO/IEC 10022:1996 | Information technology Open Systems Interconnection Physical Service Definition |
IEC 60079-0:2011 | Explosive atmospheres - Part 0: Equipment - General requirements |
IEC 60079-14:2013 | Explosive atmospheres - Part 14: Electrical installations design, selection and erection |
EN 61158-3-20:2014 | Industrial communication networks - Fieldbus specifications - Part 3-20: Data-link layer service definition - Type 20 elements |
IEC 61158-4-3:2014 | Industrial communication networks - Fieldbus specifications - Part 4-3: Data-link layer protocol specificationn - Type 3 elements |
EN 60794-1-2:2017/AC:2017-07 | OPTICAL FIBRE CABLES - PART 1-2: GENERIC SPECIFICATION - BASIC OPTICAL CABLE TEST PROCEDURES - GENERAL GUIDANCE (IEC 60794-1-2:2017) |
TIA/EIA 644 : A2001(R2012) | ELECTRICAL CHARACTERISTICS OF LOW VOLTAGE DIFFERENTIAL SIGNALING (LVDS) INTERFACE CIRCUITS |
IEC TR 61491:2010 | Electrical equipment of industrial machines - Serial data link for real-time communication between controls and drives |
EN 60079-14:2014/AC:2016 | EXPLOSIVE ATMOSPHERES - PART 14: ELECTRICAL INSTALLATIONS DESIGN, SELECTION AND ERECTION (IEC 60079-14:2013/COR1:2016) |
EN 60811-404:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 404: Miscellaneous tests - Mineral oil immersion tests for sheaths |
EN 60811-403:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 403: Miscellaneous tests - Ozone resistance test on cross-linked compounds |
IEC 60811-404:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 404: Miscellaneous tests - Mineral oil immersion tests for sheaths |
EN 61210:2010 | Connecting devices - Flat quick-connect terminations for electrical copper conductors - Safety requirements |
IEC 61158-4-18:2010 | Industrial communication networks - Fieldbus specifications - Part 4-18: Data-link layer protocol specification - Type 18 elements |
IEC 61131-2:2017 | Industrial-process measurement and control - Programmable controllers - Part 2: Equipment requirements and tests |
EN 61000-4-4:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012) |
IEC 60947-5-2:2007+AMD1:2012 CSV | Low-voltage switchgear and controlgear - Part 5-2: Control circuitdevices and switching elements - Proximity switches |
EN 60603-7-4:2010 | Connectors for electronic equipment - Part 7-4: Detail specification for 8-way, unshielded, free and fixed connectors, for data transmissions with frequencies up to 250 MHz |
TIA 485 : A1998(R2012) | ELECTRICAL CHARACTERISTICS OF GENERATORS AND RECEIVERS FOR USE IN BALANCED DIGITAL MULTIPOINT SYSTEMS |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
ISO/IEC 8482:1993 | Information technology Telecommunications and information exchange between systems Twisted pair multipoint interconnections |
IEC 61158-4-8:2007 | Industrial communication networks - Fieldbus specifications - Part 4-8: Data-link layer protocol specification - Type 8 elements |
IEC 60875-1:2015 | Fibre optic interconnecting devices and passive components - Non-wavelength-selective fibre optic branching devices - Part 1: Generic specification |
IEC 60227-5:2011 | Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 5: Flexible cables (cords) |
IEC 61158-3-20:2014 | Industrial communication networks - Fieldbus specifications - Part 3-20: Data-link layer service definition - Type 20 elements |
IEC 61784-2:2014 | Industrial communication networks - Profiles - Part 2: Additional fieldbus profiles for real-time networks based on ISO/IEC 8802-3 |
IEC 61158-4-16:2007 | Industrial communication networks - Fieldbus specifications - Part 4-16: Data-link layer protocol specification - Type 16 elements |
IEC 60811-403:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 403: Miscellaneous tests - Ozone resistance test on cross-linked compounds |
IEC 60603-7-4:2010 | Connectors for electronic equipment - Part 7-4: Detail specification for 8-way, unshielded, free and fixed connectors, for data transmissions with frequencies up to 250 MHz |
Please Login or Create an Account so you can add users to your Multi user PDF Later.
Important note : All end users must be registered with an Account prior to user licenses being assigned.
Users cannot be edited or removed once added to your Multi user PDF.
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.