BS EN 62040-1-1:2003

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Uninterruptible power systems (UPS) General and safety requirements for UPS used in operator access areas
Available format(s)

Hardcopy , PDF

Superseded date

31-03-2009

Language(s)

English

Published date

06-05-2004

1 Scope and specific applications
   1.1 Scope
   1.2 Specific applications
2 Normative references
3 Definitions
   3.1 General
   3.2 UPS electrical ratings
   3.3 Load types
   3.4 Connection to the supply
   3.5 Circuits and circuit characteristics
   3.6 Insulation
   3.7 Equipment mobility
   3.8 Insulation classes of UPS
   3.9 Enclosures
   3.10 Accessibility
   3.11 Components
   3.12 Power distribution
   3.13 Flammability
   3.14 Miscellaneous
   3.15 Telecommunication networks
4 General conditions for tests
   4.1 Operating parameters for tests
   4.2 Loads for tests
   4.3 Components
   4.4 Power interfaces
   4.5 Marking and instructions
        4.5.1 General
        4.5.2 Power rating
        4.5.3 Safety instructions
        4.5.4 Main voltage adjustment
        4.5.5 Power outlets
        4.5.6 Fuses
        4.5.7 Wiring terminals
        4.5.8 Battery terminals
        4.5.9 Controls and indicators
        4.5.10 Isolation of multiple power sources
        4.5.11 IT power systems
        4.5.12 Protection in building installation
        4.5.13 High leakage current
        4.5.14 Thermostats and other regulating devices
        4.5.15 Language
        4.5.16 Durability of markings
        4.5.17 Removable parts
        4.5.18 Replaceable batteries
        4.5.19 Operator access with a tool
        4.5.20 Battery
        4.5.21 Installation instructions
5 Fundamental design requirements
   5.1 Protection against electric shock and energy
        hazards
        5.1.1 Operator access
        5.1.2 Access to ELV wiring
        5.1.3 Discharge of capacitors in the primary
               circuit
        5.1.4 Backfeed protection
        5.1.5 Emergency switching device
   5.2 Insulation
   5.3 Limited current circuits
   5.4 Provisions for protective earthing
        5.4.1 Protective earthing
        5.4.2 Bonding
   5.5 AC and d.c. power isolation
        5.5.1 Disconnect devices
        5.5.2 Three-phase equipment
        5.5.3 Switch as a disconnect
        5.5.4 Multiple power sources
        5.5.5 Ungrounded conductors
   5.6 Overcurrent and earth fault protection
        5.6.1 Basic requirements
        5.6.2 Battery circuit protection
        5.6.3 Location of protective device
        5.6.4 Rating of protective device
   5.7 Protection of personnel - Safety interlocks
        5.7.1 Operator protection
        5.7.2 Service person protection
   5.8 Clearances, creepage distances and distances
        through insulation
   5.9 External signalling circuits
   5.10 Limited power source
6 Wiring, connections and supply
   6.1 General
   6.2 Connection to power
        6.2.1 Means of connection
   6.3 Wiring terminals for external power conductors
7 Physical requirements
   7.1 Enclosure
   7.2 Stability
   7.3 Mechanical strength
   7.4 Construction details
        7.4.1 Openings
        7.4.2 Gas concentration
        7.4.3 Equipment movement
   7.5 Resistance to fire
   7.6 Battery location
        7.6.1 Accessibility and maintainability
        7.6.2 Vibration
        7.6.3 Distance
        7.6.4 Insulation
        7.6.5 Wiring
        7.6.6 Electrolyte spillage
        7.6.7 Ventilation
        7.6.8 Charging voltages
   7.7 Temperature rise
8 Electrical requirements and simulated abnormal
   conditions
   8.1 General
        8.1.1 Earth leakage current
        8.1.2 Pluggable equipment type B UPS
   8.2 Electric strength
   8.3 Abnormal operating and fault conditions
        8.3.1 Simulation of faults
        8.3.2 Conditions for tests
9 Connection to telecommunication networks
Annexes
Annex H (informative) Guidance on protection against
        ingress of water and foreign objects
Annex L (normative) Backfeed protection test
Annex M (normative) Examples of reference load conditions
Annex N (normative) Ventilation of battery compartments
Annex X (informative) Guidance for disconnection of
        batteries during shipment
Annex ZA (normative) Normative references to international
         publications with their corresponding European
         Publication
Figures
Tables

Covers electronic uninterruptible power systems (UPS) with an electrical energy storage device in the d.c. link.

applies to electronic uninterruptible power systems (UPS) with an electrical energy storage device in the d.c. link. It is to be used with IEC 60950-1 which is referred to in this standard as \'RD\'.

Committee
PEL/22
DevelopmentNote
Supersedes 99/202878 DC. To be read in conjunction with BS EN 60950-1 (03/2003)
DocumentType
Standard
Pages
48
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

PD 6686:2006 Guidance on directives, regulations and standards related to prevention of fire and explosion in the process industries

IEC 60950-1:2005+AMD1:2009+AMD2:2013 CSV Information technology equipment - Safety - Part 1: General requirements
IEC 61008-1:2010+AMD1:2012+AMD2:2013 CSV Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part1: General rules
EN 60950-1:2006/A2:2013 INFORMATION TECHNOLOGY EQUIPMENT - SAFETY - PART 1: GENERAL REQUIREMENTS (IEC 60950-1:2005/A2:2013, MODIFIED)
EN 60417-1:2002 GRAPHICAL SYMBOLS FOR USE ON EQUIPMENT - PART 1: OVERVIEW AND APPLICATION
EN 62040-1-2:2003/corrigendum:2004
EN 60417-2:1999 Graphical symbols for use on equipment - Part 2: Symbol originals
IEC 61009-1:2010+AMD1:2012+AMD2:2013 CSV Residual current operated circuit-breakers with integral overcurrentprotection for household and similar uses (RCBOs) - Part 1: General rules
EN 61000-2-2:2002/A1:2017 ELECTROMAGNETIC COMPATIBILITY (EMC) - ENVIRONMENT - COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC LOW-VOLTAGE POWER SUPPLY SYSTEMS (IEC 61000-2-2:2002/A1:2017)
EN 62040-3:2011 Uninterruptible power systems (UPS) - Part 3: Method of specifying the performance and test requirements
IEC 62040-2:2016 Uninterruptible power systems (UPS) - Part 2: Electromagnetic compatibility (EMC) requirements
IEC 62040-1-2:2002 Uninterruptible power systems (UPS) - Part 1-2: General and safety requirements for UPS used in restricted access locations
IEC TR 60755:2008 General requirements for residual current operated protective devices
IEC 62040-3:2011 Uninterruptible power systems (UPS) - Part 3: Method of specifying the performance and test requirements
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
IEC 61000-2-2:2002+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 2-2: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems
EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)

View more information
£246.00
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.