• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

BS EN 62442-3:2014

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Energy performance of lamp controlgear Controlgear for halogen lamps and LED modules. Method of measurement to determine the efficiency of the controlgear
Available format(s)

Hardcopy , PDF

Superseded date

31-08-2018

Language(s)

English

Published date

31-07-2014

1 Scope
2 Normative references
3 Terms and definitions
4 General
5 Method of measurement and
  calculation of the efficiency of controlgear
  (transformer, convertor) for tungsten halogen
  lamps and for LED modules
Bibliography
Annex ZA (normative) - Normative references to
         international publications with their
         corresponding European publications

Specifies a measurement method for the power losses of magnetic transformers and the power losses with the standby power of electronic convertor for halogen lamps and LED modules.

This part of the IEC 62442 series defines a measurement method for the power losses of magnetic transformers and the power losses with the standby power of electronic convertor for halogen lamps and LED modules.

Also a calculation method of the efficiency for the mentioned controlgear for halogen lamps and LED modules is defined.

This part of IEC 62442 applies to electrical controlgear – lamp circuits comprised solely of the controlgear and of the lamp(s).

For multipurpose power supplies only the lighting part will be considered.

NOTE 1 Requirements for testing individual controlgear during production are not included.

It specifies the measurement method for the total input power, the standby power and the calculation method of the controlgear efficiency for all controlgear sold for domestic and normal commercial purposes operating with halogen lamps and LED modules.

This part of IEC 62442 does not apply to:

  • controlgear which form an integral part of lamps;

  • controlgear circuits with capacitors connected in series;

  • controllable wire-wound electromagnetic controlgear.

Committee
CPL/34/3
DevelopmentNote
Supersedes 12/30261933 DC. (07/2014)
DocumentType
Standard
Pages
18
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
EN 62442-3:2014/A11:2017 Identical

EN 61047:2004 DC or AC supplied electronic step-down convertors for filament lamps - Performance requirements
IEC 61347-2-13:2014+AMD1:2016 CSV Lamp controlgear - Part 2-13: Particular requirements for d.c. ora.c. supplied electronic controlgear for LED modules
EN 61558-1:2005/A1:2009 SAFETY OF POWER TRANSFORMERS, POWER SUPPLIES, REACTORS AND SIMILAR PRODUCTS - PART 1: GENERAL REQUIREMENTS AND TESTS
EN 61347-2-13:2014/A1:2017 LAMP CONTROLGEAR - PART 2-13: PARTICULAR REQUIREMENTS FOR D.C. OR A.C. SUPPLIED ELECTRONIC CONTROLGEAR FOR LED MODULES
EN 62384:2006/A1:2009 DC OR AC SUPPLIED ELECTRONIC CONTROL GEAR FOR LED MODULES - PERFORMANCE REQUIREMENTS
IEC 61347-1:2015 RLV Lamp controlgear - Part 1: General and safety requirements
IEC 61558-2-6:2009 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers
IEC 61047:2004 DC or AC supplied electronic step-down convertors for filament lamps - Performance requirements
IEC 62384:2006+AMD1:2009 CSV DC or AC supplied electronic control gear for LED modules - Performance requirements
EN 60357:2003/A11:2016 TUNGSTEN HALOGEN LAMPS (NON-VEHICLE) - PERFORMANCE SPECIFICATIONS
IEC 61558-1:2017 Safety of transformers, reactors, power supply units and combinations thereof - Part 1: General requirements and tests
EN 61347-1:2015 Lamp controlgear - Part 1: General and safety requirements
IEC GUIDE 115:2007 Application of uncertainty of measurement to conformity assessment activities in the electrotechnical sector
IEC 62442-1:2011 Energy performance of lamp controlgear - Part 1: Controlgear for fluorescent lamps - Method of measurement to determine the total input power of controlgear circuits and the efficiency of the controlgear
EN 62442-2:2014/A11:2017 ENERGY PERFORMANCE OF LAMP CONTROLGEAR - PART 2: CONTROLGEAR FOR HIGH INTENSITY DISCHARGE LAMPS (EXCLUDING FLUORESCENT LAMPS) - METHOD OF MEASUREMENT TO DETERMINE THE EFFICIENCY OF THE CONTROLGEAR
IEC 61347-2-2:2011 Lamp controlgear - Part 2-2: Particular requirements for d.c. or a.c. supplied electronic step-down convertors for filament lamps
EN 61558-2-6:2009 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers
EN 62442-1:2011/A11:2017 ENERGY PERFORMANCE OF LAMP CONTROLGEAR - PART 1: CONTROLGEAR FOR FLUORESCENT LAMPS - METHOD OF MEASUREMENT TO DETERMINE THE TOTAL INPUT POWER OF CONTROLGEAR CIRCUITS AND THE EFFICIENCY OF THE CONTROLGEAR
EN 61347-2-2:2012 Lamp controlgear - Part 2-2: Particular requirements for d.c. or a.c. supplied electronic step-down convertors for filament lamps

View more information
£134.00
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.