• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

BS IEC 62153-4-15:2015

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Metallic Communication Cable test methods Electromagnetic compatibility (EMC). Test method for measuring transfer impedance and screening attenuation or coupling attenuation with triaxial cell
Available format(s)

Hardcopy , PDF

Superseded date

20-10-2021

Language(s)

English

Published date

31-12-2015

FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 Physical background
5 Principle of the test methods
6 Test procedures
7 Sample preparation
8 Transfer impedance (short - matched)
9 Screening attenuation
10 Coupling attenuation
11 Coupling transfer function
Annex A (informative) - Principle of the triaxial test
        procedure
Annex B (informative) - Triaxial cell
Annex C (informative) - Cut off frequencies, higher
        order modes
Annex D (informative) - Coupling transfer function
Annex E (informative) - Attenuation versus scattering
        parameter S[21]
Annex F (informative) - Application of a moveable
        shorting plane
Annex G (informative) - Correction in case the receiver
        input impedance R is higher than the characteristic
        impedance of the outer circuit Z[2]
Bibliography

Defines the procedures for measuring with triaxial cell the transfer impedance, screening attenuation or the coupling attenuation of connectors, cable assemblies and components, e.g. accessories for analogue and digital transmission systems and equipment for communication networks and cabling (in accordance with the scope of IEC technical committee 46).

This part of IEC 62153 specifies the procedures for measuring with triaxial cell the transfer impedance, screening attenuation or the coupling attenuation of connectors, cable assemblies and components, e.g. accessories for analogue and digital transmission systems and equipment for communication networks and cabling (in accordance with the scope of IEC technical committee 46).

Measurements can be achieved by applying the device under test direct to the triaxial cell or with the tube in tube method in accordance with IEC 62153-4-7.

Committee
EPL/46
DevelopmentNote
Supersedes 13/30279876 DC. (01/2016)
DocumentType
Standard
Pages
44
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
IEC 62153-4-15:2015 Identical

IEC 62153-4-3:2013 Metallic communication cable test methods - Part 4-3: Electromagnetic compatibility (EMC) - Surface transfer impedance - Triaxial method
IEC 62153-4-7:2015 Metallic communication cable test methods - Part 4-7: Electromagnetic compatibility (EMC) - Test method for measuring of transfer impedance Z<sub>T</sub> and screening attenuation a<sub>S</sub> or coupling attenuation a<sub>C</sub> of connectors and assemblies up to and above 3 GHz - Triaxial tube in tube method
IEC 62153-4-4:2015 Metallic communication cable test methods - Part 4-4: Electromagnetic compatibility (EMC) - Test method for measuring of the screening attenuation as up to and above 3 GHz, triaxial method
IEC 62153-4-8:2006 Metallic communication cable test methods - Part 4-8: Electromagnetic compatibility (EMC) - Capacitive coupling admittance
IEC TS 62153-4-1:2014 Metallic communication cable test methods - Part 4-1: Electromagnetic compatibility (EMC) - Introduction to electromagnetic screening measurements
IEC 61196-1:2005 Coaxial communication cables - Part 1: Generic specification - General, definitions and requirements
IEC 62153-4-9:2008 Metallic communication cable test methods - Part 4-9: Electromagnetic compatibility (EMC) - Coupling attenuation of screened balanced cables, triaxial method
IEC 62153-4-10:2015 Metallic communication cable test methods - Part 4-10: Electromagnetic compatibility (EMC) - Transfer impedance and screening attenuation of feed-throughs and electromagnetic gaskets - Double coaxial test method

View more information
£232.00
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.