CEI EN 50377-15-1 : 2012
Current
The latest, up-to-date edition.
CONNECTOR SETS AND INTERCONNECT COMPONENTS TO BE USED IN OPTICAL FIBRE COMMUNICATION SYSTEMS - PRODUCT SPECIFICATIONS - PART 15-1: TYPE MPO WITH 12-FIBRE PPS FERRULES TERMINATED ON IEC 60793-2 CATEGORY A1A MULTIMODE FIBRE FOR 50/125 MICRON MULTIMODE FIBRE
Hardcopy , PDF
English
01-01-2012
Foreword
1 Scope
2 Normative references
3 Introduction
4 Variants
5 Dimensional requirements
6 Tests
7 Test report
8 Product qualification requirements
Annex A (normative) - Sample size and product sourcing
requirements
Annex B (informative) - Reference connector details
Annex C (normative) - Requirements for launch condition
(Encircled flux)
Bibliography
Describes the initial, start of life dimensional, optical, mechanical and environmental performance requirements which a terminated and assembled 12 fibre multimode MPO connector set (plug adapter plug) must meet in order for it to be categorised as an EN standard product.
Committee |
CT 86
|
DevelopmentNote |
Classificazione CEI 86-348. (06/2012)
|
DocumentType |
Standard
|
Pages |
36
|
PublisherName |
Comitato Elettrotecnico Italiano
|
Status |
Current
|
Standards | Relationship |
EN 50377-15-1:2011 | Identical |
IEC 61754-18:2001 | Fibre optic connector interfaces - Part 18: Type MT-RJ connector family |
IEC PAS 61755-3-31:2007 | Fibre optic connector optical interfaces - Part 3-31: Optical interface - 8 degrees angled PC end-face PPS rectangular ferrule, single mode fibre |
EN 61300-2-18:2005 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-18: Tests - Dry heat - High temperature endurance |
IEC 61300-3-28:2012 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-28: Examinations and measurements - Transient loss |
EN 61300-2-1:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-1: Tests - Vibration (sinusoidal) |
EN 61300-3-4:2013 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-4: Examinations and measurements - Attenuation |
EN 60794-2:2017 | Optical fibre cables - Part 2: Indoor cables - Sectional specification |
EN 61300-2-17:2011 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-17: Tests - Cold |
EN 60794-2-30:2008 | Optical fibre cables - Part 2-30: Indoor cables - Family specification for ribbon cables |
IEC 60794-2-30:2008 | Optical fibre cables - Part 2-30: Indoor cables - Family specification for ribbon cables |
EN 61300-2-2:2009/corrigendum:2009 | FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS - BASIC TEST AND MEASUREMENT PROCEDURES - PART 2-2: TESTS - MATING DURABILITY |
IEC 60793-2:2015 | Optical fibres - Part 2: Product specifications - General |
IEC 61300-2-1:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-1: Tests - Vibration (sinusoidal) |
IEC 61300-2-12:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-12: Tests - Impact |
EN 61300-2-6:2011 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-6: Tests - Tensile strength of coupling mechanism |
ISO/IEC 11801:2002 | Information technology Generic cabling for customer premises |
EN 61300-2-22:2007 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-22: Tests - Change of temperature |
EN 61300-2-44:2013 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-44: Tests - Flexing of the strain relief of fibre optic devices |
IEC 61300-2-17:2010 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-17: Tests - Cold |
IEC 61753-1:2007 | Fibre optic interconnecting devices and passive components performance standard - Part 1: General and guidance for performance standards |
EN 61753-1:2007 | Fibre optic interconnecting devices and passive components performance standard - Part 1: General and guidance for performance standards |
IEC 61300-3-34:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-34: Examinations and measurements - Attenuation of random mated connectors |
EN 61300-3-30:2003 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-30: Examinations and measurements - Polish angle and fibre position on single ferrule multifibre connectors |
IEC 61300-2-18:2005 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-18: Tests - Dry heat - High temperature endurance |
IEC 61300-2-22:2007 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-22: Tests - Change of temperature |
IEC 61300-3-6:2008 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-6: Examinations and measurements - Return loss |
IEC 61754-10:2005 | Fibre optic connector interfaces - Part 10: Type Mini-MPO connector family |
EN 61300-3-6:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-6: Examinations and measurements - Return loss |
EN 61280-1-4:2010 | Fibre optic communication subsystem test procedures - Part 1-4: General communication subsystems - Light source encircled flux measurement method |
EN 61754-18:2002/corrigendum:2002 | FIBRE OPTIC CONNECTOR INTERFACES - PART 18: TYPE MT-RJ CONNECTOR FAMILY |
EN 61300-2-12:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-12: Tests - Impact |
IEC 61300-3-4:2012 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-4: Examinations and measurements - Attenuation |
EN 61300-2-4:1997 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-4: Tests - Fibre/cable retention |
IEC 61300-2-42:2014 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-42: Tests - Static side load for strain relief |
EN 61300-3-28:2012 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-28: Examinations and measurements - Transient loss |
EN 60793-2:2016 | Optical fibres - Part 2: Product specifications - General |
IEC 61300-3-30:2003 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-30: Examinations and measurements - Polish angle and fibre position on single ferrule multifibre connectors |
IEC 61300-2-44:2013 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-44: Tests - Flexing of the strain relief of fibre optic devices |
IEC 60794-2:2017 | Optical fibre cables - Part 2: Indoor cables - Sectional specification |
IEC 61300-2-2:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-2: Tests - Mating durability |
IEC 61300-2-4:1995 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-4: Tests - Fibre/cable retention |
EN 61300-3-27:1997 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-27: Examinations and measurements - Measurement method for the hole location of a multiway connector plug |
EN 61300-2-42:2014 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-42: Tests - Static side load for strain relief |
EN 61754-10:2005 | Fibre optic connector interfaces - Part 10: Type Mini-MPO connector family |
IEC 61300-2-19:2012 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-19: Tests - Damp heat (steady state) |
IEC 61300-3-27:1997 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-27: Examinations and measurements - Measurement method for the hole location of a multiway connector plug |
EN 61300-2-19:2013 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-19: Tests - Damp heat (steady state) |
IEC 61300-2-6:2010 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-6: Tests - Tensile strength of coupling mechanism |
EN 61754-7:2008 | Fibre optic interconnecting devices and passive components - Fibre optic connector interfaces - Part 7: Type MPO connector family |
EN 61300-3-34:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-34: Examinations and measurements - Attenuation of random mated connectors |
IEC 61754-7:2008 | Fibre optic interconnecting devices and passive components - Fibre optic connector interfaces - Part 7: Type MPO connector family |
IEC 61280-1-4:2009 | Fibre optic communication subsystem test procedures - Part 1-4: General communication subsystems - Light source encircled flux measurement method |
EN 186000-1 : 1993 | GENERIC SPECIFICATION: CONNECTOR SETS FOR OPTICAL FIBRES AND CABLES - REQUIREMENTS, TEST METHODS AND QUALIFICATION APPROVAL PROCEDURES |
Please Login or Create an Account so you can add users to your Multi user PDF Later.
Important note : All end users must be registered with an Account prior to user licenses being assigned.
Users cannot be edited or removed once added to your Multi user PDF.
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.