• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

CEN/TS 16429:2013

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

View Superseded by
withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Stationary source emissions - Sampling and determination of hydrogen chloride content in ducts and stacks - Infrared analytical technique

Withdrawn date

10-03-2023

Published date

13-03-2013

Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Principle
5 Sampling system
6 Analyser equipment
7 Determination of the characteristics of the
   method: analyser, sampling and conditioning
   line
8 Field operation
9 Ongoing quality control
10 Expression of results
11 Measurement report
Annex A (informative) - Examples of schematics of
        non-dispersive infrared spectrometer
Annex B (informative) - Example of assessment of
        compliance of non-dispersive infrared
        method for HCl with requirements on emission
        measurements
Annex C (informative) - Procedure for correction of
        data from drift effect
Bibliography

This Technical Specification specifies an automatic method for determination of the mass concentration of hydrogen chloride (HCl) in ducts and stacks emitting to atmosphere. It describes the infrared analytical technique, including the sampling and gas conditioning system. The method shall should fulfil the performance characteristics requirements of this Technical Specification and the expanded uncertainty is less than 20 % relative at the daily Emission Limit Value (ELV).In order to use an alternative method to this method, it is necessary to demonstrate equivalence according to the Technical Specification CEN/TS 14793. It is necessary that the capability to demonstrate equivalence is officially recognised by the national accreditation body or law.

Committee
CEN/TC 264
DocumentType
Technical Specification
PublisherName
Comite Europeen de Normalisation
Status
Withdrawn
SupersededBy

EN 15267-3:2007 Air quality - Certification of automated measuring systems - Part 3: Performance criteria and test procedures for automated measuring systems for monitoring emissions from stationary sources
CEN/TS 14793:2005 Stationary source emission - Intralaboratory validation procedure for an alternative method compared to a reference method
ISO 14956:2002 Air quality Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty
EN 15259:2007 Air quality - Measurement of stationary source emissions - Requirements for measurement sections and sites and for the measurement objective, plan and report
ISO/IEC Guide 99:2007 International vocabulary of metrology Basic and general concepts and associated terms (VIM)
EN 13284-1:2017 Stationary source emissions - Determination of low range mass concentration of dust - Part 1: Manual gravimetric method
EN 14181:2014 Stationary source emissions - Quality assurance of automated measuring systems
EN ISO 14956 : 2002 AIR QUALITY - EVALUATION OF THE SUITABILITY OF A MEASUREMENT PROCEDURE BY COMPARISON WITH A REQUIRED MEASUREMENT UNCERTAINTY
ENV 13005 : DRAFT 1999 GUIDE TO THE EXPRESSION OF UNCERTAINTY IN MEASUREMENT
EN 14790:2017 Stationary source emissions - Determination of the water vapour in ducts - Standard reference method

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.